SearcharxivSearch

arXiv subjects

Sean Preins

Publications and source records attributed to Sean Preins.

8 recordsLinked to original sources

Beam Test of a SiPM-on-Tile ZDC Prototype with 5.3 GeV Positrons at Jefferson Laboratory

We report on a beam test of a Silicon Photo-Multiplier (SiPM)-on-tile Zero Degree Calorimeter (ZDC) prototype developed for the future Electron-Ion Collider (EIC). The detector implements the staggered scintillator-tile geometry envisioned for the final detector and includes 370 instrumented channels, corresponding to O(10%) of the full ZDC. The detector was tested using a 5.3 GeV positron beam at Jefferson Laboratory. We measure the energy response, shower shape, and spatial reconstruction performance of the detector and compare these results with simulation. These studies provide key input for the optimization of the final ePIC ZDC design.

physics.ins-det

Calibration of an Irradiated Prototype for the EIC Zero-Degree Calorimeter

We study the response of a prototype Zero-Degree Calorimeter (ZDC) detector to irradiation equivalent to 10$^{11}$ 1-MeV $n_{\text{eq}}/\text{cm}^{2}$, which matches the expected exposure after one year of operation at full nominal luminosity at the future Electron-Ion Collider (EIC). The prototype, which consists of 563 channels and represents about 10 percent of the final ZDC design in terms of both channel count and detector volume, was irradiated at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL) with proton beams. We demonstrate that, despite significant radiation damage to the SiPMs and non-uniform degradation across the detector volume, the detector can be successfully calibrated on a channel-by-channel basis using cosmic-ray data. The damage profile, similar to what is expected in the experiment, varies by an order of magnitude or more across the detector. Even for the most heavily damaged channels, the signal-to-noise ratio for a MIP signal remains above 5. This study provides a realistic test of the system's performance under irradiation. It complements previous SiPM-specific irradiation studies and will inform the future operation of the ZDC and other detectors that use SiPM-on-tile technology.

physics.ins-det

A borehole muon detector with SiPM-on-tile technology

We developed a compact and rugged muon detector designed for deployment in boreholes. The detector uses a SiPM-on-tile approach in which silicon photomultipliers are directly coupled to scintillator tiles, thereby eliminating the need for wavelength-shifting fibers and long scintillator bars. The modular design is based on a 64-channel unit, 140~cm in length and 80~mm in diameter, composed of $5 \times 5$~cm$^{2}$ scintillator tiles coupled to SiPMs, powered and read out using off-the-shelf electronics. The detector has an average muon detection efficiency above 95\% and acceptance over 5$^\circ$--60$^\circ$ in zenith and 0$^\circ$--360$^\circ$ in azimuth. Simulations indicate that reconstruction combining hit positions and energy deposits achieves a zenith resolution of 1.5--4.0$^\circ$ across most of the zenith range. This work demonstrates a compact, rugged, and cost-effective borehole muon detector based on the SiPM-on-tile approach, offering a new alternative for muon tomography.

physics.ins-det

Measurement of SiPM Dark Currents and Annealing Recovery for Fluences Expected in ePIC Calorimeters at the Electron-Ion Collider

Silicon photomultipliers (SiPMs) will be used to read out all calorimeters in the ePIC experiment at the Electron-Ion Collider (EIC). A thorough characterization of the radiation damage expected for SiPMs under anticipated EIC fluences is essential for accurate simulations, detector design, and effective operational strategies. In this study, we evaluate radiation damage for the specific SiPM models chosen for ePIC across the complete fluence range anticipated at the EIC, $10^8$ to $10^{12}$ 1-MeV $n_{\mathrm{eq}}$/cm$^2$ per year, depending on the calorimeter location. The SiPMs were irradiated using a 64 MeV proton beam provided by the University of California, Davis 76" Cyclotron. We measured the SiPM dark-current as a function of fluence and bias voltage and investigated the effectiveness of high-temperature annealing to recover radiation damage. These results provide a comprehensive reference for the design, simulation, and operational planning of all ePIC calorimeter systems.

physics.ins-det

First-Ever Deployment of a SiPM-on-Tile Calorimeter in a Collider: A Parasitic Test with 200 GeV $pp$ Collisions at RHIC

We describe the testing of a prototype SiPM-on-tile iron-scintillator calorimeter at the Relativistic Heavy Ion Collider (RHIC) during its 200 GeV $pp$ run in 2024. The prototype, measuring $20 \times 20 \, \text{cm}^{2}$ and 24 radiation lengths in depth, was positioned in the STAR experimental hall, approximately 8 m from the interaction point and 65 cm from the beam line, covering a pseudorapidity range of about $3.1<\eta<3.4$. By using the dark current of a reference SiPM as a radiation monitor, we estimate that the prototype was exposed to a fluence of about $10^{10}$ 1-MeV $n_{\mathrm{eq}}$/cm$^2$. Channel-by-channel calibration was performed in a data-driven way with the signature from minimum-ionizing particles during beam-on conditions. A Geant4 detector simulation, with inputs from the Pythia8 event generator, describes measurements of energy spectra and hit multiplicities reasonably well. These results mark the first deployment, commissioning, calibration, and long-term operation of a SiPM-on-tile calorimeter in a collider environment. This experimental campaign will guide detector designs and operational strategies for the ePIC detector at the future EIC, as well as other applications.

physics.ins-det

Beam Test of the First Prototype of SiPM-on-Tile Calorimeter Insert for the Electron-Ion Collider Using 4 GeV Positrons at Jefferson Laboratory

We recently proposed a high-granularity calorimeter insert for the Electron-Ion Collider (EIC) that uses plastic scintillator tiles read out by SiPMs. Among its innovative features are an ASIC-away-of-SiPM strategy for reducing cooling requirements and minimizing space use, along with employing 3D-printed frames to reduce optical crosstalk and dead areas. To evaluate these features, we built a 40-channel prototype and tested it using a 4 GeV positron beam at Jefferson Laboratory. The measured energy spectra and 3D shower shapes are well described by simulations, confirming the effectiveness of the design, construction techniques, and calibration strategy. This constitutes the first use of SiPM-on-tile technology in EIC detector designs.

physics.ins-det

Studies of time resolution, light yield, and crosstalk using SiPM-on-tile calorimetry for the future Electron-Ion Collider

We recently proposed a high-granularity calorimeter insert for the Electron-Ion Collider (EIC) that is based on plastic scintillator tiles readout with silicon photomultipliers. In this work, we concretize its design by characterizing its building blocks with measurements of light yield, optical crosstalk, and timing resolutions using cosmic-rays, an LED, and a beta source. We also compared two approaches for the optical isolation of cells: ``megatiles'' with grooved boundaries between cells, and a 3D-printed plastic frame hosting individual cells. We found that the latter suppresses optical crosstalk to negligible levels while providing an easier assembly method. Overall, these performance studies can help inform calorimeter design and realistic simulations of 5D showers (time, energy, position) for the EIC and other experiments.

physics.ins-det

A high-granularity calorimeter insert based on SiPM-on-tile technology at the future Electron-Ion Collider

We present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage close to the beampipe, while solving challenges arising from the beam-crossing angle and mechanical integration. It yields a compensated response that is linear over the energy range of interest for the EIC. Its energy resolution meets the requirements set in the EIC Yellow Report even with a basic reconstruction algorithm. Moreover, this detector will provide 5D shower data (position, energy, and time), which can be exploited with machine-learning techniques. This detector concept has the potential to unleash the power of imaging calorimetry at the EIC to enable measurements at extreme kinematics in electron-proton and electron-nucleus collisions.

physics.ins-det