SearcharxivSearch

arXiv subjects

Sebastian Gstir

Publications and source records attributed to Sebastian Gstir.

4 recordsLinked to original sources

Franson-Interferometric Bounds on Entangled Two-Photon Absorption

Entangled photons offer quantum correlations with no classical analogue. In entangled pair two-photon absorption (ETPA), absorption rate is predicted to scale linearly rather than quadratically with photon flux, promising molecular excitation at fluxes far below the classical threshold. Reported ETPA cross sections nevertheless vary widely across experiments, largely since the observable, the differential of the transmitted flux or weak fluorescence, is difficult to separate from scattering and linear losses. We present a method which uses Franson interference to study entangled two-photon absorption through delay-dependent coincidence measurements on dye molecules. Applying the method to Rhodamine 6G, we observe a small asymmetry in the Franson interference envelope and obtain a model-derived effective cross section of approximately 2.1 E(-21) centimeter squared for Rhodamine 6G. However, the estimated systematic uncertainty does not allow a definitive ETPA assignment. Instead, the experiment establishes a quantitative bound on the ETPA response and provides a background-free benchmark for future measurements.

physics.chem-ph

Nonlinear response of telecom-wavelength superconducting single-photon detectors

We measure the nonlinearity of a telecom-wavelength superconducting nanowire single-photon detector via incoherent beam combination. At typical photon count rates and detector bias current, the observed relative deviation from a perfectly linear response is in the order of 0.1% when the flux is doubled. This arises from a balance between the counteracting nonlinearities of deadtime-induced detector saturation and of multi-photon detections. The observed behaviour is modelled empirically, which suffices for a correction of measured data. In addition, statistical simulations, taking into account the measured recovery of the detection efficiency, provide insight into possible mechanisms of multi-photon detection.

quant-ph

Towards probing for hypercomplex quantum mechanics in a waveguide interferometer

We experimentally investigate the suitability of a multi-path waveguide interferometer with mechanical shutters for performing a test for hypercomplex quantum mechanics. Probing the interferometer with coherent light we systematically analyse the influence of experimental imperfections that could lead to a false-positive test result. In particular, we analyse the effects of detector nonlinearity, input-power and phase fluctuations on different timescales, closed-state transmissivity of shutters and crosstalk between different interferometer paths. In our experiment, a seemingly small shutter transmissivity in the order of about $2 \times 10^{-4}$ is the main source of systematic error, which suggests that this is a key imperfection to monitor and mitigate in future experiments.

quant-ph

Hybrid waveguide-bulk multi-path interferometer with switchable amplitude and phase

We design and realise a hybrid interferometer consisting of three paths based on integrated as well as on bulk optical components. This hybrid construction offers a good compromise between stability and footprint on one side and means of intervention on the other. As experimentally verified by the absence of higher-order interferences, amplitude and phase can be manipulated in all paths independently. In conjunction with single photons, the setup can, therefore, be applied for fundamental investigations on quantum mechanics.

physics.optics