SearcharxivSearch

arXiv subjects

Sebastian Nowak

Publications and source records attributed to Sebastian Nowak.

13 recordsLinked to original sources

Secure On-Premise Deployment of Open-Weights Large Language Models in Radiology: An Isolation-First Architecture with Prospective Pilot Evaluation

Purpose: To design, implement, evaluate, and report on the regulatory requirements of a self-hosted LLM infrastructure for radiology adhering to the principle of least privilege, emphasizing technical feasibility, network isolation, and clinical utility. Materials and Methods: The isolation-first, containerized LLM inference stack relies on strict network segmentation, host-enforced egress filtering, and active isolation monitoring preventing unauthorized external connectivity. An accompanying deployment package provides automated isolation and hardening tests. The system served the open-weights DeepSeek-R1 model via vLLM. In a one-week pilot phase, 22 residents and radiologists were free to use 10 predefined prompt-templates whenever they considered them useful in daily work. Afterward, they rated clinical utility and system stability on an 0-10 Likert scale and reported observed critical errors in model output. Results: The applied institutional governance pathway achieved approval from clinic management, compliance, data protection and information security officers for processing unanonymized PHI. The system was rated stable and user friendly during the pilot. Source text-anchored tasks, such as report corrections or simplifications, and radiology guideline recommendations received the highest utility ratings, whereas open-ended conclusion generation based on findings resulted in the highest frequency of critical errors, such as clinically relevant hallucinations or omissions. Conclusion: The proposed isolation-first on-premise architecture enabled overcoming regulatory borders, showed promising clinical utility in text-anchored tasks and is the current base to serve open-weights LLMs as an official service of a German University Hospital with over 10,000 employees. The deployment package were made publicly available (https://github.com/ukbonn/ukb-gpt).

cs.CY

Informed Deep Abstaining Classifier: Investigating noise-robust training for diagnostic decision support systems

Image-based diagnostic decision support systems (DDSS) utilizing deep learning have the potential to optimize clinical workflows. However, developing DDSS requires extensive datasets with expert annotations and is therefore costly. Leveraging report contents from radiological data bases with Natural Language Processing to annotate the corresponding image data promises to replace labor-intensive manual annotation. As mining "real world" databases can introduce label noise, noise-robust training losses are of great interest. However, current noise-robust losses do not consider noise estimations that can for example be derived based on the performance of the automatic label generator used. In this study, we expand the noise-robust Deep Abstaining Classifier (DAC) loss to an Informed Deep Abstaining Classifier (IDAC) loss by incorporating noise level estimations during training. Our findings demonstrate that IDAC enhances the noise robustness compared to DAC and several state-of-the-art loss functions. The results are obtained on various simulated noise levels using a public chest X-ray data set. These findings are reproduced on an in-house noisy data set, where labels were extracted from the clinical systems of the University Hospital Bonn by a text-based transformer. The IDAC can therefore be a valuable tool for researchers, companies or clinics aiming to develop accurate and reliable DDSS from routine clinical data.

cs.CV

Commissioning of low particle flux for proton beams at MedAustron

MedAustron is a synchrotron-based particle therapy centre located in Wiener Neustadt, Austria. It features three irradiation rooms for particle therapy, where proton beams with energies up to 252.7 MeV and carbon ions of up to 402.8 MeV/u are available for cancer treatment. In addition to the treatment rooms, MedAustron features a unique beamline exclusively for non-clinical research (NCR). This research beamline is also commissioned for proton energies up to 800 MeV, while available carbon ion energies correspond to the ones available in the clinical treatment rooms. Based on the requirements for particle therapy, all irradiation rooms offer particle rates of up to 10^9 particles/s for protons and 10^7 particles/s for carbon ions. However, for research purposes, lower particle fluxes are required and were therefore commissioned for the NCR beamline. Three particle flux settings with particle rates ranging from ~2.4x10^3 particles/s to ~5.2x10^6 particles/s were established for seven proton energies below 252.7 MeV. In addition to the particle rate, the spot sizes and beam energies were measured for these settings. Furthermore, three low flux settings for 800 MeV protons with particle rates ranging from ~2x10^3 particles/s to ~1.3x10^6 particles/s were commissioned. Since the commissioned low flux settings are in a regime well below the limits of the available standard beam diagnostics, setting up the beam under these new operational conditions entirely relied on the use of external detectors. Furthermore, a beam position measurement based alignment without using the standard beam profile monitors was performed for 800 MeV protons.

physics.acc-ph

Hardware Implementation of a Fast Algorithm for the Reconstruction of Muon Tracks in ATLAS Muon Drift-Tube Chambers for the First-Level Muon Trigger at the HL-LHC

The High-Luminosity LHC will provide the unique opportunity to explore the nature of physics beyond the Standard Model of strong and electroweak interactions. Highly selective first level triggers are essential for the physics programme of the ATLAS experiment at the HL-LHC where the instantaneous luminosity will exceed the LHC Run 1 instantaneous luminosity by almost an order of magnitude. The ATLAS first level muon trigger rate is dominated by low momentum muons, selected due to the moderate momentum resolution of the resistive plate and thin gap trigger chambers. This limitation can be overcome by including the data of the precision muon drift tube (MDT) chambers in the first level trigger decision. This requires the fast continuous transfer of the MDT hits to the off-detector trigger logic and a fast track reconstruction algorithm performed in the trigger logic. In order to demonstrate the feasibility of reconstructing tracks in MDT chambers within the short available first-level trigger latency of about 3~$\mu$s we implemented a seeded Hough transform on the ARM Cortex A9 microprocessor of a Xilinx Zynq FPGA and studied its performance with test-beam data recorded in CERN's Gamma Irradiation Facility. We could show that by using the ARM processor's Neon Single Instruction Multiple Data Engine to carry out 4 floating point operations in parallel the challenging latency requirement can be matched.

physics.ins-det

Performance of Drift-Tube Detectors at High Counting Rates for High-Luminosity LHC Upgrades

The performance of pressurized drift-tube detectors at very high background rates has been studied at the Gamma Irradiation Facility (GIF) at CERN and in an intense 20 MeV proton beam at the Munich Van-der-Graaf tandem accelerator for applications in large-area precision muon tracking at high-luminosity upgrades of the Large Hadron Collider (LHC). The ATLAS muon drifttube (MDT) chambers with 30 mm tube diameter have been designed to cope with and neutron background hit rates of up to 500 Hz/square cm. Background rates of up to 14 kHz/square cm are expected at LHC upgrades. The test results with standard MDT readout electronics show that the reduction of the drift-tube diameter to 15 mm, while leaving the operating parameters unchanged, vastly increases the rate capability well beyond the requirements. The development of new small-diameter muon drift-tube (sMDT) chambers for LHC upgrades is completed. Further improvements of tracking efficiency and spatial resolution at high counting rates will be achieved with upgraded readout electronics employing improved signal shaping for high counting rates.

physics.ins-det

Performance of the new amplifier-shaper-discriminator chip for the ATLAS MDT chambers at the HL-LHC

The Phase-II Upgrade of the ATLAS Muon Detector requires new electronics for the readout of the MDT drift tubes. The first processing stage, the Amplifier-Shaper-Discriminator (ASD), determines the performance of the readout for crucial parameters like time resolution, gain uniformity, efficiency and noise rejection. An 8-channel ASD chip, using the IBM 130 nm CMOS 8RF-DM technology, has been designed, produced and tested. The area of the chip is 2.2 x 2.9 square mm size. We present results of detailed measurements as well as a comparision with simulation results of the chip behaviour at three different levels of detail.

physics.ins-det

Optimisation of the Read-out Electronics of Muon Drift-Tube Chambers for Very High Background Rates at HL-LHC and Future Colliders

In the ATLAS Muon Spectrometer, Monitored Drift Tube (MDT) chambers and sMDT chambers with half of the tube diameter of the MDTs are used for precision muon track reconstruction. The sMDT chambers are designed for operation at high counting rates due to neutron and gamma background irradiation expected for the HL-LHC and future hadron colliders. The existing MDT read-out electronics uses bipolar signal shaping which causes an undershoot of opposite polarity and same charge after a signal pulse. At high counting rates and short electronics dead time used for the sMDTs, signal pulses pile up on the undershoot of preceding background pulses leading to a reduction of the signal amplitude and a jitter in the drift time measurement and, therefore, to a degradation of drift tube efficiency and spatial resolution. In order to further increase the rate capability of sMDT tubes, baseline restoration can be used in the read-out electronics to suppress the pile-up effects. A discrete bipolar shaping circuit with baseline restoration has been developed and used for reading out sMDT tubes under irradiation with a 24 MBq 90Sr source. The measurements results show a substantial improvement of the performance of the sMDT tubes at high counting rates.

physics.ins-det

Precision Muon Tracking at Future Hadron Colliders with sMDT Chambers

Small-diameter muon drift tube (sMDT) chambers are a cost-effective technology for high-precision muon tracking. The rate capability of the sMDT chambers has been extensively tested at the Gamma Irradiation Facility at CERN in view of expected rates at future high-energy hadron colliders. Results show that it fulfills the requirements over most of the acceptance of muon detectors. The optimization of the read-out electronics to further increase the rate capability of the detectors is discussed. Chambers of this type are under construction for upgrades of the muon spectrometer of the ATLAS detector at high LHC luminosities. Design and construction procedures have been optimized for mass production while providing a precision of better than 10 micrometers in the sense wire positions and the mechanical stability required to cover large areas.

physics.ins-det

Construction and test of high precision drift-tube (sMDT) chambers for the ATLAS muon spectrometer

For the upgrade of the ATLAS muon spectrometer in March 2014 new muon tracking chambers (sMDT) with drift-tubes of 15 mm diameter, half of the value of the standard ATLAS Monitored Drift-Tubes (MDT) chambers, and 10~$μ$m positioning accuracy of the sense wires have been constructed. The new chambers are designed to be fully compatible with the present ATLAS services but, with respect to the previously installed ATLAS MDT chambers, they are assembled in a more compact geometry and they deploy two additional tube layers that provide redundant rack information. The chambers are composed of 8 layers of in total 624 aluminium drift-tubes. The assembly of a chamber is completed within a week. A semi-automatized production line is used for the assembly of the drift-tubes prior to the chamber assembly. The production procedures and the quality control tests of the single components and of the complete chambers will be discussed. The wire position in the completed chambers have been measured by using a coordinate measuring machine.

physics.ins-det

From noncommutative kappa-Minkowski to Minkowski space-time

We show that free $κ$-Minkowski space field theory is equivalent to a relativistically invariant, non local, free field theory on Minkowski space-time. The field theory we obtain has in spectrum a relativistic mode of arbitrary mass $m$ and a Planck mass tachyon. We show that while the energy momentum for the relativistic mode is essentially the standard one, it diverges for the tachyon, so that there are no asymptotic tachyonic states in the theory. It also follows that the dispersion relation is not modified, so that, in particular, in this theory the speed of light is energy-independent.

hep-th

Lorentz invariance of scalar field action on $κ$-Minkowski space-time

We construct field theory on noncommutative $κ$-Minkowski space-time. Having the Lorentz action on the noncommutative space-time coordinates we show that the field lagrangian is invariant. We show that noncommutativity requires replacing the Leibnitz rule with the coproduct one.

hep-th

Doubly Special Relativity and de Sitter space

In this paper we recall the construction of Doubly Special Relativity (DSR) as a theory with energy-momentum space being the four dimensional de Sitter space. Then the bases of the DSR theory can be understood as different coordinate systems on this space. We investigate the emerging geometrical picture of Doubly Special Relativity by presenting the basis independent features of DSR that include the non-commutative structure of space-time and the phase space algebra. Next we investigate the relation between our geometric formulation and the one based on quantum $κ$-deformations of the Poincaré algebra. Finally we re-derive the five-dimensional differential calculus using the geometric method, and use it to write down the deformed Klein-Gordon equation and to analyze its plane wave solutions.

hep-th

Non-commutative space-time of Doubly Special Relativity theories

Doubly Special Relativity (DSR) theory is a recently proposed theory with two observer-independent scales (of velocity and mass), which is to describe a kinematic structure underlining the theory of Quantum Gravity. We observe that there is infinitely many DSR constructions of the energy-momentum sector, each of whose can be promoted to the $κ$-Poincaré quantum (Hopf) algebra. Then we use the co-product of this algebra and the known construction of $κ$-deformed phase space via Heisenberg double in order to derive the non-commutative space-time structure and description of the whole of the DSR phase space. Next we show that contrary to the ambiguous structure of the energy momentum sector, the space-time of the DSR theory is unique and equivalent to the theory with non-commutative space-time proposed long ago by Snyder. This theory provides non-commutative version of Minkowski space-time enjoying ordinary Lorentz symmetry. It turns out that when one builds a natural phase space on this space-time, its intrinsic length parameter $\ell$ becomes observer-independent.

hep-th