SearcharxivSearch

arXiv subjects

Sebastian Rosenzweig

Publications and source records attributed to Sebastian Rosenzweig.

11 recordsLinked to original sources

DualTrack: Sensorless 3D Ultrasound needs Local and Global Context

Three-dimensional ultrasound (US) offers many clinical advantages over conventional 2D imaging, yet its widespread adoption is limited by the cost and complexity of traditional 3D systems. Sensorless 3D US, which uses deep learning to estimate a 3D probe trajectory from a sequence of 2D US images, is a promising alternative. Local features, such as speckle patterns, can help predict frame-to-frame motion, while global features, such as coarse shapes and anatomical structures, can situate the scan relative to anatomy and help predict its general shape. In prior approaches, global features are either ignored or tightly coupled with local feature extraction, restricting the ability to robustly model these two complementary aspects. We propose DualTrack, a novel dual-encoder architecture that leverages decoupled local and global encoders specialized for their respective scales of feature extraction. The local encoder uses dense spatiotemporal convolutions to capture fine-grained features, while the global encoder utilizes an image backbone (e.g., a 2D CNN or foundation model) and temporal attention layers to embed high-level anatomical features and long-range dependencies. A lightweight fusion module then combines these features to estimate the trajectory. Experimental results on a large public benchmark show that DualTrack achieves state-of-the-art accuracy and globally consistent 3D reconstructions, outperforming previous methods and yielding an average reconstruction error below 5 mm.

cs.CV

Quantitative Magnetic Resonance Imaging by Nonlinear Inversion of the Bloch Equations

Purpose: Development of a generic model-based reconstruction framework for multi-parametric quantitative MRI that can be used with data from different pulse sequences. Methods: Generic nonlinear model-based reconstruction for quantitative MRI estimates parametric maps directly from the acquired k-space by numerical optimization. This requires numerically accurate and efficient methods to solve the Bloch equations and their partial derivatives. In this work, we combine direct sensitivity analysis and pre-computed state-transition matrices into a generic framework for calibrationless model-based reconstruction that can be applied to different pulse sequences. As a proof-of-concept, the method is implemented and validated for quantitative $T_1$ and $T_2$ mapping with single-shot inversion-recovery (IR) FLASH and IR bSSFP sequences in simulations, phantoms, and the human brain. Results: The direct sensitivity analysis enables a highly accurate and numerically stable calculation of the derivatives. The state-transition matrices efficiently exploit repeating patterns in pulse sequences, speeding up the calculation by a factor of 10 for the examples considered in this work, while preserving the accuracy of native ODE solvers. The generic model-based method reproduces quantitative results of previous model-based reconstructions based on the known analytical solutions for radial IR FLASH. For IR bSFFP it produces accurate $T_1$ and $T_2$ maps for the NIST phantom in numerical simulations and experiments. Feasibility is also shown for human brain, although results are affected by magnetization transfer effects. Conclusion: By developing efficient tools for numerical optimizations using the Bloch equations as forward model, this work enables generic model-based reconstruction for quantitative MRI.

physics.med-ph

Free-Breathing Myocardial T1 Mapping using Inversion-Recovery Radial FLASH and Motion-Resolved Model-Based Reconstruction

Purpose: To develop a free-breathing myocardial T1 mapping technique using inversion-recovery (IR) radial fast low-angle shot (FLASH) and calibrationless motion-resolved model-based reconstruction. Methods: Free-running (free-breathing, retrospective cardiac gating) IR radial FLASH is used for data acquisition at 3T. First, to reduce the waiting time between inversions, an analytical formula is derived that takes the incomplete T1 recovery into account for an accurate T1 calculation. Second, the respiratory motion signal is estimated from the k-space center of the contrast varying acquisition using an adapted singular spectrum analysis (SSA-FARY) technique. Third, a motion-resolved model-based reconstruction is used to estimate both parameter and coil sensitivity maps directly from the sorted k-space data. Thus, spatiotemporal total variation, in addition to the spatial sparsity constraints, can be directly applied to the parameter maps. Validations are performed on an experimental phantom, eleven human subjects, and a young landrace pig with myocardial infarction. Results: In comparison to an IR spin-echo reference, phantom results confirm good T1 accuracy when reducing the waiting time from five seconds to one second using the new correction. The motion-resolved model-based reconstruction further improves precision compared to the spatial regularization-only reconstruction. Aside from showing that a reliable respiratory motion signal can be estimated using modified SSA-FARY, in vivo studies demonstrate that dynamic myocardial T1 maps can be obtained within two minutes with good precision and repeatability. Conclusion: Motion-resolved myocardial T1 mapping during free-breathing with good accuracy, precision and repeatability can be achieved by combining inversion-recovery radial FLASH, self-gating and a calibrationless motion-resolved model-based reconstruction.

physics.med-ph

Model-Based Reconstruction for Simultaneous Multi-Slice T1 Mapping using Single-Shot Inversion-Recovery Radial FLASH

Purpose: To develop a single-shot multi-slice T1 mapping method by combing simultaneous multi-slice (SMS) excitations, single-shot inversion-recovery (IR) radial fast low-angle shot (FLASH) and a nonlinear model-based reconstruction method. Methods: SMS excitations are combined with a single-shot IR radial FLASH sequence for data acquisition. A previously developed single-slice calibrationless model-based reconstruction is extended to SMS, formulating the estimation of parameter maps and coil sensitivities from all slices as a single nonlinear inverse problem. Joint-sparsity constraints are further applied to the parameter maps to improve T1 precision. Validations of the proposed method are performed for a phantom and for the human brain and liver in six healthy adult subjects. Results: Phantom results confirm good T1 accuracy and precision of the simultaneously acquired multi-slice T1 maps in comparison to single-slice references. In-vivo human brain studies demonstrate the better performance of SMS acquisitions compared to the conventional spoke-interleaved multi-slice acquisition using model-based reconstruction. Apart from good accuracy and precision, the results of six healthy subjects in both brain and abdominal studies confirm good repeatability between scan and re-scans. The proposed method can simultaneously acquire T1 maps for five slices of a human brain ($0.75 \times 0.75 \times 5$ mm$^3$) or three slices of the abdomen ($1.25 \times 1.25 \times 6$ mm$^3$) within four seconds. Conclusion: The IR SMS radial FLASH acquisition together with a non-linear model-based reconstruction enable rapid high-resolution multi-slice T1 mapping with good accuracy, precision, and repeatability.

physics.med-ph

Cardiac and Respiratory Self-Gating in Radial MRI using an Adapted Singular Spectrum Analysis (SSA-FARY)

Cardiac Magnetic Resonance Imaging (MRI) is time-consuming and error-prone. To ease the patient's burden and to increase the efficiency and robustness of cardiac exams, interest in methods based on continuous steady-state acquisition and self-gating has been growing in recent years. Self-gating methods extract the cardiac and respiratory signals from the measurement data and then retrospectively sort the data into cardiac and respiratory phases. Repeated breathholds and synchronization with the heart beat using some external device as required in conventional MRI are then not necessary. In this work, we introduce a novel self-gating method for radially acquired data based on a dimensionality reduction technique for time-series analysis (SSA-FARY). Building on Singular Spectrum Analysis, a zero-padded, time-delayed embedding of the auto-calibration data is analyzed using Principle Component Analysis. We demonstrate the basic functionality of SSA-FARY using numerical simulations and apply it to in-vivo cardiac radial single-slice bSSFP and Simultaneous Multi-Slice radiofrequency-spoiled gradient-echo measurements, as well as to Stack-of-Stars bSSFP measurements. SSA-FARY reliably detects the cardiac and respiratory motion and separates it from noise. We utilize the generated signals for high-dimensional image reconstruction using parallel imaging and compressed sensing with in-plane wavelet and (spatio-)temporal total-variation regularization.

physics.med-ph

Frequency-modulated SSFP with radial sampling and subspace reconstruction: A time-efficient alternative to phase-cycled bSSFP

Purpose: A novel subspace-based reconstruction method for frequency-modulated balanced steady-state free precession (fmSSFP) MRI is presented. In this work, suitable data acquisition schemes, subspace sizes, and efficiencies for banding removal are investigated. Theory and Methods: By combining a fmSSFP MRI sequence with a 3D stack-of-stars trajectory, scan efficiency is maximized as spectral information is obtained without intermediate preparation phases. A memory-efficient reconstruction routine is implemented by introducing the low-frequency Fourier transform as a subspace which allows for the formulation of a convex reconstruction problem. The removal of banding artifacts is investigated by comparing the proposed acquisition and reconstruction technique to phase-cycled bSSFP MRI. Aliasing properties of different undersampling schemes are analyzed and water/fat separation is demonstrated by reweighting the reconstructed subspace coefficients to generate virtual spectral responses in a post-processing step. Results: A simple root-of-sum-of-squares combination of the reconstructed subspace coefficients yields high-SNR images with the characteristic bSSFP contrast but without banding artifacts. Compared to Golden-Angle trajectories, turn-based sampling schemes were superior in minimizing aliasing across reconstructed subspace coefficients. Water/fat separated images of the human knee were obtained by reweighting subspace coefficients. Conclusion: The novel subspace-based fmSSFP MRI technique emerges as a time-efficient alternative to phase-cycled bSSFP. The method does not need intermediate preparation phases, offers high SNR and avoids banding artifacts. Reweighting of the reconstructed subspace coefficients allows for generating virtual spectral responses with applications to water/fat separation.

physics.med-ph

ENLIVE: An Efficient Nonlinear Method for Calibrationless and Robust Parallel Imaging

Robustness against data inconsistencies, imaging artifacts and acquisition speed are crucial factors limiting the possible range of applications for magnetic resonance imaging (MRI). Therefore, we report a novel calibrationless parallel imaging technique which simultaneously estimates coil profiles and image content in a relaxed forward model. Our method is robust against a wide class of data inconsistencies, minimizes imaging artifacts and is comparably fast combining important advantages of many conceptually different state-of-the-art parallel imaging approaches. Depending on the experimental setting, data can be undersampled well below the Nyquist limit. Here, even high acceleration factors yield excellent imaging results while being robust to noise and the occurrence of phase singularities in the image domain, as we show on different data. Moreover, our method successfully reconstructs acquisitions with insufficient field-of-view. We further compare our approach to ESPIRiT and SAKE using spin-echo and gradient echo MRI data from the human head and knee. In addition, we show its applicability to non-Cartesian imaging on radial FLASH cardiac MRI data. Using theoretical considerations, we show that ENLIVE can be related to a low-rank formulation of blind multi-channel deconvolution, explaining why it inherently promotes low-rank solutions.

physics.med-ph

Simple Auto-Calibrated Gradient Delay Estimation From Few Spokes Using Radial Intersections (RING)

Purpose: To develop a simple and robust tool for the estimation of gradient delays from highly undersampled radial k-space data. Theory: In radial imaging gradient delays induce parallel and orthogonal trajectory shifts, which can be described using an ellipse model. The intersection points of the radial spokes, which can be estimated by spoke-by-spoke comparison of k-space samples, distinctly determine the parameters of the ellipse. Using the proposed method (RING), these parameters can be obtained using a least-squares fit and utilized for the correction of gradient delays. Methods: The functionality and accuracy of the proposed RING method is validated and compared to correlation-based gradient-delay estimation from opposing spokes using numerical simulations, phantom and in vivo heart measurements. Results: In all experiments, RING robustly provides accurate gradient delay estimations even for as few as three radial spokes. Conclusion: The simple and straightforward to implement RING method provides accurate gradient delay estimation for highly undersampled radial imaging. Keywords: trajectory correction, radial imaging, gradient delay, artifacts, system imperfections, RING

physics.med-ph

Simultaneous Multi-Slice MRI using Cartesian and Radial FLASH and Regularized Nonlinear Inversion: SMS-NLINV

Purpose: The development of a calibrationless parallel imaging method for accelerated simultaneous multi-slice (SMS) MRI based on Regularized Nonlinear Inversion (NLINV), evaluated using Cartesian and radial FLASH. Theory and Methods: NLINV is a parallel imaging method that jointly estimates image content and coil sensitivities using a Newton-type method with regularization. Here, NLINV is extended to SMS-NLINV for reconstruction and separation of all simultaneously acquired slices. The performance of the extended method is evaluated for different sampling schemes using phantom and in-vivo experiments based on Cartesian and radial SMS-FLASH sequences. Results: The basic algorithm was validated in Cartesian experiments by comparison with ESPIRiT. For Cartesian and radial sampling, improved results are demonstrated compared to single-slice experiments, and it is further shown that sampling schemes using complementary samples outperform schemes with the same samples in each partition. Conclusion: The extension of the NLINV algorithm for SMS data was implemented and successfully demonstrated in combination with a Cartesian and radial SMS-FLASH sequence.

physics.med-ph

Simultaneous multi-slice reconstruction by Regularized Nonlinear Inversion

Increasing imaging speed is of utmost importance in in-vivo magnetic resonance imaging (MRI). With simultaneous multi-slice (SMS) MRI we can simultaneously acquire several slices of an object, which allows for higher undersampling factors compared to single- or conventional multi-slice measurements by exploiting axial coil sensitivity information. In this thesis, we give a short introduction to the physical principles of MRI, cover the basics of a FLASH based SMS MRI sequence and perform tests to verify its accuracy: We check the fidelity of the slice distance as well as the flip angle and confirm the square-root-like signal-to-noise ratio benefit of SMS compared to conventional multi-slice experiments. A g-factor analysis is used to determine a favorable Cartesian undersampling scheme for multi-slice data. Common reconstruction strategies for SMS MRI make use of previously estimated coil sensitivities to solve a linear equation. Here, we propose a new method of SMS MRI based on Regularized Nonlinear Inversion (NLINV): SMS-NLINV. This method does not require a priori knowledge about the coil sensitivities and is attractive especially for real-time imaging where coil sensitivities may change due to motion or interactive changes to the slice position. We characterize the algorithm and present reconstructed phantom and in-vivo images.

physics.med-ph

Confinement of two-dimensional rods in slit pores and square cavities

Using Monte Carlo simulation, we analyse the behaviour of two-dimensional hard rods in four different types of geometric confinement: (i) a slit pore where the particles are confined between two parallel walls with homeotropic anchoring; (ii) a hybrid slit pore formed by a planar and a homeotropic wall; square cavities that frustrate the orientational order by imposing either (iii) homeotropic or (iv) planar wall anchoring. We present results for the state diagram as a function of the packing fraction and the degree of confinement. Under extreme confinement, unexpected states appear with lower symmetries than those of the corresponding stable states in bulk, such as the formation of states that break the anchoring constraints or the symmetry imposed by the surfaces. In both types of square cavities the particles form disclinations at intermediate densities. At high densities, however, the elastic stress is relaxed via the formation of domain walls where the director rotates abruptly by ninety degrees.

cond-mat.soft