SearcharxivSearch

arXiv subjects

Sebastian Weingärtner

Publications and source records attributed to Sebastian Weingärtner.

6 recordsLinked to original sources

Set-Based Groupwise Registration for Variable-Length, Variable-Contrast Cardiac MRI

Quantitative cardiac magnetic resonance imaging (MRI) enables non-invasive myocardial tissue characterization but relies on robust motion correction within these variable-length, variable-contrast image sequences. Groupwise registration, which simultaneously aligns all images, has shown greater robustness than pairwise registration for motion correction. However, current deep-learning-based groupwise registration methods cannot generalize across MRI sequences: the architecture typically encodes input data as a fixed-length channel stack, which rigidly couples network design to protocol-specific sequence length, input ordering, and contrast dynamics. At inference time, any change in imaging protocols will render the network unusable. In this work, we introduce \emph{\AnyTwoReg}, a new set-based groupwise registration framework that takes a quantitative MRI sequence as an unordered set. This set formulation fundamentally decouples network design from sequence length and input ordering. By utilizing a shared encoder and correlation-guided feature aggregation, \emph{\AnyTwoReg} constructs a permutation-invariant canonical reference for registration, and learns a permutation-equivariant mapping from images to deformation fields. Additionally, we extract contrast-insensitive image features from an existing foundation model to handle extreme contrast variations. Trained exclusively on a single public $T_1$ mapping dataset (STONE, sequence length $L=11$), \AnyTwoReg generalizes to two unseen quantitative MRI datasets (MOLLI, ASL) with variable lengths ($L \in [11, 60]$) and different contrast dynamics. It achieves strong cross-protocol generalization in a zero-shot manner, and consistently improves downstream quantitative mapping quality. Notably, while designed for quantitative MRI sequences, our framework is directly applicable to Cine MRI sequences for inter-cardiac-phase registration.

eess.IV

Deep Learning Assisted Outer Volume Removal for Highly-Accelerated Real-Time Dynamic MRI

Real-time (RT) dynamic MRI plays a vital role in capturing rapid physiological processes, offering unique insights into organ motion and function. Among these applications, RT cine MRI is particularly important for functional assessment of the heart with high temporal resolution. RT imaging enables free-breathing, ungated imaging of cardiac motion, making it a crucial alternative for patients who cannot tolerate conventional breath-hold, ECG-gated acquisitions. However, achieving high acceleration rates in RT cine MRI is challenging due to aliasing artifacts from extra-cardiac tissues, particularly at high undersampling factors. In this study, we propose a novel outer volume removal (OVR) method to address this challenge by eliminating aliasing contributions from non-cardiac regions in a post-processing framework. Our approach estimates the outer volume signal for each timeframe using composite temporal images from time-interleaved undersampling patterns, which inherently contain pseudo-periodic ghosting artifacts. A deep learning (DL) model is trained to identify and remove these artifacts, producing a clean outer volume estimate that is subsequently subtracted from the corresponding k-space data. The final reconstruction is performed with a physics-driven DL (PD-DL) method trained using an OVR-specific loss function to restore high spatio-temporal resolution images. Experimental results show that the proposed method at high accelerations achieves image quality that is visually comparable to clinical baseline images, while outperforming conventional reconstruction techniques, both qualitatively and quantitatively. The proposed approach provides a practical and effective solution for artifact reduction in RT cine MRI without requiring acquisition modifications, offering a pathway to higher acceleration rates while preserving diagnostic quality.

eess.IV

Adaptive Radiofrequency Shimming in MRI using Reconfigurable Dielectric Materials

Inhomogeneity of the transmitted radiofrequency field B1+ is a major factor hindering the image quality in Magnetic Resonance Imaging (MRI) at high field strengths. Here, a novel approach is presented, to locally modulate the B1+ utilizing an array of high permittivity materials with switchable connections. A 3$\times$3 array of barium titanate suspension elements was constructed, with two PIN diode-based switchable connectors per element. Electromagnetic simulations were performed to determine configurations that produce strong B1+ modulation. Remote B1+ field switching was tested in a disk- and and a torso-shaped phantom at 3T by applying different bias voltages to the PIN diodes. The attained B1+ modulation was assessed at various switching pattern positions and various depths within the phantoms. The configuration with the strongest effect size has produced up to 11% modulation in simulations at 15 mm depth, with excellent translation properties. The effects were successfully replicated in phantoms, with a 5 V bias voltage producing up to 11.6$\pm$0.2% modulation. At the relative depth of the human heart, up to 6% of modulation was observed in the torso phantom. The presented method may provide a promising direction for cost-effective, and adaptive B1+ shimming without changes to the scanner hardware.

physics.med-ph

Color-map recommendation for MR relaxometry maps

Purpose: To harmonize the use of color for MR relaxometry maps and therefore recommend the use of specific color-maps for representing T1 and T2 maps. Methods: Perceptually linearized color-maps were chosen to have similar color settings as those proposed by Griswold et al. in 2018. A Delphi process, polling the opinion of a panel of 81 experts, was used to generate consensus on the suitability of these maps. Results: Consensus was reached on the suitability of the logarithm-processed Lipari color-map for T1 and the logarithm-processed Navia color-map for T2. There was consensus on color bars being mandatory and on the use of a specific value indicating invalidity. There was no consensus on whether the ranges should be fixed per anatomy. Conclusion: The authors recommend the use of the logarithm-processed Lipari color map for displaying quantitative T1 maps and R1 maps; likewise, the authors recommend the logarithm-processed Navia color-map for displaying T2, T2*, R2 and R2* maps.

physics.med-ph

Bayesian Uncertainty Estimation by Hamiltonian Monte Carlo: Applications to Cardiac MRI Segmentation

Deep learning (DL)-based methods have achieved state-of-the-art performance for many medical image segmentation tasks. Nevertheless, recent studies show that deep neural networks (DNNs) can be miscalibrated and overconfident, leading to "silent failures" that are risky for clinical applications. Bayesian DL provides an intuitive approach to DL failure detection, based on posterior probability estimation. However, the posterior is intractable for large medical image segmentation DNNs. To tackle this challenge, we propose a Bayesian learning framework using Hamiltonian Monte Carlo (HMC), tempered by cold posterior (CP) to accommodate medical data augmentation, named HMC-CP. For HMC computation, we further propose a cyclical annealing strategy, capturing both local and global geometries of the posterior distribution, enabling highly efficient Bayesian DNN training with the same computational budget as training a single DNN. The resulting Bayesian DNN outputs an ensemble segmentation along with the segmentation uncertainty. We evaluate the proposed HMC-CP extensively on cardiac magnetic resonance image (MRI) segmentation, using in-domain steady-state free precession (SSFP) cine images as well as out-of-domain datasets of quantitative T1 and T2 mapping. Our results show that the proposed method improves both segmentation accuracy and uncertainty estimation for in- and out-of-domain data, compared with well-established baseline methods such as Monte Carlo Dropout and Deep Ensembles. Additionally, we establish a conceptual link between HMC and the commonly known stochastic gradient descent (SGD) and provide general insight into the uncertainty of DL. This uncertainty is implicitly encoded in the training dynamics but often overlooked. With reliable uncertainty estimation, our method provides a promising direction toward trustworthy DL in clinical applications.

eess.IV

Accelerated Coronary MRI with sRAKI: A Database-Free Self-Consistent Neural Network k-space Reconstruction for Arbitrary Undersampling

This study aims to accelerate coronary MRI using a novel reconstruction algorithm, called self-consistent robust artificial-neural-networks for k-space interpolation (sRAKI). sRAKI performs iterative parallel imaging reconstruction by enforcing coil self-consistency using subject-specific neural networks. This approach extends the linear convolutions in SPIRiT to nonlinear interpolation using convolutional neural networks (CNNs). These CNNs are trained individually for each scan using the scan-specific autocalibrating signal (ACS) data. Reconstruction is performed by imposing the learned self-consistency and data-consistency enabling sRAKI to support random undersampling patterns. Fully-sampled targeted right coronary artery MRI was acquired in six healthy subjects for evaluation. The data were retrospectively undersampled, and reconstructed using SPIRiT, $\ell_1$-SPIRiT and sRAKI for acceleration rates of 2 to 5. Additionally, prospectively undersampled whole-heart coronary MRI was acquired to further evaluate performance. The results indicate that sRAKI reduces noise amplification and blurring artifacts compared with SPIRiT and $\ell_1$-SPIRiT, especially at high acceleration rates in targeted data. Quantitative analysis shows that sRAKI improves normalized mean-squared-error (~44% and ~21% over SPIRiT and $\ell_1$-SPIRiT at rate 5) and vessel sharpness (~10% and ~20% over SPIRiT and $\ell_1$-SPIRiT at rate 5). In addition, whole-heart data shows the sharpest coronary arteries when resolved using sRAKI, with 11% and 15% improvement in vessel sharpness over SPIRiT and $\ell_1$-SPIRiT, respectively. Thus, sRAKI is a database-free neural network-based reconstruction technique that may further accelerate coronary MRI with arbitrary undersampling patterns, while improving noise resilience over linear parallel imaging and image sharpness over $\ell_1$ regularization techniques.

eess.IV