SearcharxivSearch

arXiv subjects

Seiji Kawamura

Publications and source records attributed to Seiji Kawamura.

At least 19 recordsLinked to original sources

Quantum Noise Reduction in the Space-based Gravitational Wave Antenna DECIGO Using Optical Springs and Homodyne Detection scheme

The DECi-hertz Interferometer Gravitational-wave Observatory (DECIGO) is a planned space-based, next-generation gravitational wave detector aimed at observing primordial gravitational waves originating form cosmic inflation. This work focuses on reducing the quantum noise, in the instrument's observation band of 0.1 to 10 Hz, by employing optical springs and a homodyne detection scheme. Although detuning 1000\,km long arm cavities was previously considered ineffective due to quantum state degradation from diffraction losses, we revisit this problem by formulating a new, rigorous model for quantum state of light by accounting for the vacuum state mixing as a result of diffraction losses. This work shows that high sensitivities can be achieved by employing optimal configurations of optical springs and homodyne detection schemes even with diffraction losses. These improvements alone are still not sufficient to achieve sensitivities to detect primordial gravitational waves as other technical noises limit further improvement.

gr-qc

Quantum Noise from Vacuum Field Injection in Optical Cavities with Diffraction-related Loss

The space-based gravitational wave detector DECIGO is designed to observe primordial gravitational waves with 1,000 km Fabry-Perot cavities. Its sensitivity is limited by quantum noise, and although squeezing can suppress it, its effectiveness is reduced by diffraction-related loss, which leads to the injection of vacuum fields into the interferometer. This paper presents a rigorous treatment of quantum field propagation in the presence of diffraction and higher-order mode losses, deriving input-output relations, and modeling their impact via an optomechanical block diagram. The analysis shows that diffraction-induced vacuum fields slightly increase radiation pressure noise, while shot noise remains unaffected. Nevertheless, cavity detuning with homodyne detection yields a dip in the noise spectrum. By accurately capturing these effects, this framework enables a detailed study of sensitivity improvements made by either just detuning the main cavity while implementing homodyne detection, or by combining this with optical-spring quantum locking using auxiliary cavities, laying a firm foundation for enhancing DECIGO's capability to detect primordial gravitational waves.

physics.optics

Jiggled interferometer: Ground-based gravitational wave detector using rapidly-repeated free-falling test masses

We propose the Jiggled Interferometer (JIGI), a novel ground-based gravitational wave detector employing low-frequency noise mitigation similar to that of space-based detectors. Using rapidly-repeated free-fall test masses, JIGI eliminates seismic and suspension thermal noise during free fall. Compared to the Juggled Interferometer, it offers improved angular stability and avoids tracking lasers. We analyze detrending -- a required step to remove actuation-induced noise -- and show sensitivity gains of about four orders of magnitude in the 0.1-0.3 Hz band, relative to seismic and suspension noise extrapolated from the Cosmic Explorer.

gr-qc

Proof-of-Principle Experiment on a Displacement-Noise-Free Neutron Interferometer for Gravitational Wave Detection

The displacement-noise-free interferometer (DFI) is designed to eliminate all displacement-induced noise while retaining sensitivity to gravitational wave (GW) signals. Ground-based DFIs suffer from physical arm-length limitations, resulting in poor sensitivity at frequencies below 1 kHz. To address this, previous research introduced a neutron-based DFI, which replaces laser light with neutrons and achieves exceptional sensitivity down to a few hertz. In this study, we conducted a proof-of-principle experiment using a pulsed neutron source at the Japan Proton Accelerator Research Complex (J- PARC). Despite practical constraints that led to deviations from the ideal experimental design, we optimized the setup and developed a novel analysis method that successfully cancels displacement noise while preserving simulated GW signals. This work presents the first successful demonstration of a neutron DFI and a neutron interferometer for GW detection.

physics.ins-det

SILVIA: Ultra-precision formation flying demonstration for space-based interferometry

We propose SILVIA (Space Interferometer Laboratory Voyaging towards Innovative Applications), a mission concept designed to demonstrate ultra-precision formation flying between three spacecraft separated by 100 m. SILVIA aims to achieve sub-micrometer precision in relative distance control by integrating spacecraft sensors, laser interferometry, low-thrust and low-noise micro-propulsion for real-time measurement and control of distances and relative orientations between spacecraft. A 100-meter-scale mission in a near-circular low Earth orbit has been identified as an ideal, cost-effective setting for demonstrating SILVIA, as this configuration maintains a good balance between small relative perturbations and low risk for collision. This mission will fill the current technology gap towards future missions, including gravitational wave observatories such as DECIGO (DECihertz Interferometer Gravitational wave Observatory), designed to detect the primordial gravitational wave background, and high-contrast nulling infrared interferometers like LIFE (Large Interferometer for Exoplanets), designed for direct imaging of thermal emissions from nearby terrestrial planet candidates. The mission concept and its key technologies are outlined, paving the way for the next generation of high-precision space-based observatories.

astro-ph.IM

Significance of Fabry-Perot cavities for space gravitational wave antenna DECIGO

The future Japanese project for the detection of gravitational waves in space is planned as DECIGO. To achieve various scientific missions, including the verification of cosmic inflation through the detection of primordial gravitational waves as the main objective, DECIGO is designed to have high sensitivity in the frequency band from $0.1$ to $1$ Hz, with arms of length 1000 km. Furthermore, the use of the Fabry-Perot cavity in these arms has been established for the DECIGO project. In this paper, we scrutinize the significance of the Fabry-Perot cavity for promoting this project, with a focus on the possibility of observing gravitational waves from cosmic inflation and binary compact star systems as indicators. The results show that using the Fabry-Perot cavity is extremely beneficial for detecting them, and it is anticipated to enable the opening of a new window in gravitational wave astronomy.

gr-qc

Sagnac-type neutron displacement-noise-free interferometeric gravitational-wave detector

The detection of low-frequency gravitational waves on Earth requires the reduction of displacement noise, which dominates the low-frequency band. One method to cancel test mass displacement noise is a neutron displacement-noise-free interferometer (DFI). This paper proposes a new neutron DFI configuration, a Sagnac-type neutron DFI, which uses a Sagnac interferometer in place of the Mach-Zehnder interferometer. We demonstrate that a sensitivity of the Sagnac-type neutron DFI is higher than that of a conventional neutron DFI with the same interferometer scale. This configuration is particularly significant for neutron DFIs with limited space for construction and limited flux from available neutron sources.

gr-qc

Optimization of quantum noise in space gravitational-wave antenna DECIGO with optical-spring quantum locking considering mixture of vacuum fluctuations in homodyne detection

Quantum locking using optical spring and homodyne detection has been devised to reduce quantum noise that limits the sensitivity of DECIGO, a space-based gravitational wave antenna in the frequency band around 0.1 Hz for detection of primordial gravitational waves. The reduction in the upper limit of energy density $Ω_{\mathrm{GW}}$ from $2{\times}10^{-15}$ to $1{\times}10^{-16}$, as inferred from recent observations, necessitates improved sensitivity in DECIGO to meet its primary science goals. To accurately evaluate the effectiveness of this method, this paper considers a detection mechanism that takes into account the influence of vacuum fluctuations on homodyne detection. In addition, an advanced signal processing method is devised to efficiently utilize signals from each photodetector, and design parameters for this configuration are optimized for the quantum noise. Our results show that this method is effective in reducing quantum noise, despite the detrimental impact of vacuum fluctuations on its sensitivity.

gr-qc

First-step experiment in developing optical-spring quantum locking for DECIGO: sensitivity optimization for simulated quantum noise by completing the square

DECi-hertz Interferometer Gravitational Wave Observatory (DECIGO) is a future mission for a space-borne laser interferometer. DECIGO has 1,000-km-long arm cavities mainly to detect the primordial gravitational waves (PGW) at lower frequencies around 0.1 Hz. Observations in the electromagnetic spectrum have lowered the bounds on the upper limit of PGW energy density ($Ω_{\rm gw} \sim 10^{-15} \to 10^{-16}$). As a result, DECIGO's target sensitivity, which is mainly limited by quantum noise, needs further improvement. To maximize the feasibility of detection while constrained by DECIGO's large diffraction loss, a quantum locking technique with an optical spring was theoretically proposed to improve the signal-to-noise ratio of the PGW. In this paper, we experimentally verify one key element of the optical-spring quantum locking: sensitivity optimization by completing the square of multiple detector outputs. This experiment is operated on a simplified tabletop optical setup with classical noise simulating quantum noise. We succeed in getting the best of the sensitivities with two different laser powers by the square completion method.

gr-qc

Displacement-noise-free interferometeric gravitational-wave detector using unidirectional neutrons with four speeds

For further gravitational wave (GW) detections, it is significant to invent a technique to reduce all kinds of mirror displacement noise dominant at low frequencies for ground-based detectors. The neutron displacement-noise-free interferometer (DFI) is one of the tools to reduce all the mirror displacement noise at lower frequencies. In this paper, we describe a further simplified configuration of a neutron DFI in terms of neutron incidence direction. In the new configuration, neutrons enter the interferometer with unidirectional incidence at four speeds as opposed to two bidirectional incidences of opposite directions at two speeds as reported previously. This simplification of the neutron DFI is significant for proof-of-principle experiments.

gr-qc

Can the phase of radiation pressure fluctuations be flipped in a single path for laser interferometric gravitational wave detectors?

Radiation pressure (RP) noise, one component of quantum noise, can limit the sensitivity of laser interferometric gravitational wave (GW) detectors at lower frequencies. We conceived a possible RP noise cancellation method, using phase flipped ponderomotive-squeezed light (FPSL) incident on free-mass mirrors in interferometers' arms. This possibility is investigated under the constraint that the method is for space-based GW detectors in a broad frequency band lower than 1 Hz without using a long optical cavity. Considering various patterns in a single path small-scale case to generate the FPSL, we proved that no configuration exists in the single path case.

gr-qc

Conceptual design and science cases of a juggled interferometer for gravitational wave detection

The Juggled interferometer (JIFO) is an earth-based gravitational wave detector using repeatedly free-falling test masses. With no worries of seismic noise and suspension thermal noise, the JIFO can have much better sensitivity at lower frequencies than the current earth-based gravitational wave detectors. The data readout method of a JIFO could be challenging if one adopts the fringe-locking method. We present a phase reconstruction method in this paper by building up a complex function which has a fringe-independent signal-to-noise ratio. Considering the displacement noise budget of the Einstein Telescope (ET), we show that the juggled test masses significantly improve the sensitivity at 0.1-2.5$\,$Hz even with discontinuous data. The science cases brought with the improved sensitivity would include detecting quasi-normal modes of black holes with $10^4-10^5\,M_{\odot}$, testing Brans-Dicke theory with black-hole and neutron-star inspirals, and detecting primordial-black-hole-related gravitational waves.

gr-qc

Neutron displacement noise-free interferometer for gravitational-wave detection

An interferometer design that cancels all displacement noises of its test masses and maintains a gravitational-wave (GW) signal by combining multiple detector signals is called a displacement noise-free interferometer (DFI). The idea has been considered previously for a laser interferometer. However, a limitation of a laser DFI is that its sensitive frequency band is too high for astrophysical GW sources, $\sim 10^5\,{\rm Hz}$ even for a kilometer-sized interferometer. To circumvent this limitation, in this paper, we propose a neutron DFI, in which neutrons are used instead of light. Since neutrons have velocities much lower than the speed of light, the sensitive frequency band of a neutron DFI can be lowered down to $\sim 10^{-1}\,{\rm Hz}$. Therefore, a neutron DFI can be utilized for detecting GWs that are inaccessible by an ordinary laser interferometer on the ground.

gr-qc

Displacement-noise-free neutron interferometer for gravitational wave detection using a single Mach-Zehnder configuration

The improvement of sensitivity to gravitational waves (GWs) at lower frequencies is still challenging on account of displacement noise. One of the solutions is the neutron displacement-noise-free interferometer (DFI). We focus on a simplification of the detector configuration by taking advantage of the ability to adjust the neutron speed depending on the configuration. The new configuration consists of two beamsplitters and two mirrors, which constitute a single Mach-Zehnder interferometer (MZI). It is simpler than the configuration with two MZIs in previous research. All displacement noise of mirrors and beamsplitters can be canceled in the frequency domain. This cancellation can be explained intuitively using a phasor diagram.

gr-qc

Optimization of Design Parameters for Gravitational Wave Detector DECIGO Including Fundamental Noises

The DECi hertz Interferometer Gravitational-Wave Observatory (DECIGO) is a space gravitational wave (GW) detector. DECIGO was originally designed to be sensitive enough to observe primordial GW background (PGW). However, due to the lowered upper limit of the PGW by the Planck observation, further improvement of the target sensitivity of DECIGO is required. In the previous studies, DECIGO's parameters were optimized to maximize the signal-to-noise ratio (SNR) of the PGW to quantum noise including the effect of diffraction loss. To simulate the SNR more realistically, we optimize DECIGO's parameters considering the GWs from double white dwarfs (DWDs) and the thermal noise of test masses. We consider two cases of the cutoff frequency of GWs from DWDs. In addition, we consider two kinds of thermal noise: thermal noise in a residual gas and internal thermal noise. To investigate how the mirror geometry affects the sensitivity, we calculate it by changing the mirror mass, keeping the mirror thickness, and vice versa. As a result, we obtained the optimums for the parameters that maximize the SNR that depends on the mirror radius. This result shows that a thick mirror with a large radius gives a good SNR and enables us to optimize the design of DECIGO based on the feasibility study of the mirror size in the future.

gr-qc

Inspiraling double compact object detection and lensing rate -- forecast for DECIGO and B-DECIGO

Emergence of gravitational wave (GW) astronomy revived the interest in exploring the low frequency GW spectrum inaccessible from the ground. Satellite GW observatory DECIGO in its original configuration and the currently proposed smaller scale B-DECIGO are aimed to cover deci-Hertz part of the GW spectrum, which fills the gap between LISA mili-Hertz and deca- to kilo-Hertz range probed by ground-based detectors. In this paper we forecast the detection rates of inspiraling double compact objects (DCOs) and the unresolved confusion noise from these sources in DECIGO and B-DECIGO. In the context of DECIGO we use, for the first time, the population synthesis intrinsic inspiral rates of NS-NS, BH-NS and BH-BH systems. We also estimate the expected gravitational lensing rates of such sources for DECIGO and B-DECIGO. The result is that yearly detection of DCOs inspirals for the DECIGO is of order of $10^4 - 10^5$, while for a much smaller scale B-DECIGO they are about $10^2 - 10^4$ depending on the DCO population considered. Taking into account that considerable part of these events would be detectable by ground-based GW observatories the added value of DECIGO/B-DECIGO could be substantial. DECIGO will also be able to register $5-50$ lensed NS-NS inspirals and up to O(100) BH-BH inspirals. On the contrary, predictions for the B-DECIGO are pessimistic: only the optimistic common envelope scenario of DCO formation could yield a few lensed BH-BH inspirals per year. We also address the question of the magnification bias in the GW event catalogs of DECIGO and B-DECIGO.

astro-ph.HE

Investigation of crackling noise in the vibration isolation systems of the KAGRA gravitational wave detector

Gravitational wave detectors, such as KAGRA, require complex mirror suspension systems to reach high sensitivity. One particular concern in these suspensions is the presence of crackling noise, where motion of the steel crystal structure disturbs material defects, causing impulse force release and exciting mirror motion. Crackling in the Geometric Anti Spring filters (GAS) in KAGRA's suspension system could introduce noise in the gravitational wave detection band. We investigate crackling noise in a miniature GAS with a low-frequency cyclical stress. We developed a scaling law between miniature and KAGRA GAS. Applying experimental results to the scaling law allows us to estimate the upper limit of crackling noise in KAGRA. It is found that crackling noise should be below the target sensitivity for gravitational waves above 60 Hz.

physics.ins-det

Improvement of the target sensitivity in DECIGO by optimizing its parameters for quantum noise including the effect of diffraction loss

DECIGO is the future Japanese gravitational wave detector in outer space. We previously set the default design parameters to provide a good target sensitivity to detect the primordial gravitational waves (GWs). However, the updated upper limit of the primordial GWs by the Planck observations motivated us for further optimization of the target sensitivity. Previously, we had not considered optical diffraction loss due to the very long cavity length. In this paper, we optimize various DECIGO parameters by maximizing the signal-to-noise ratio (SNR), for the primordial GWs to quantum noise including the effects of diffraction loss. We evaluated the power spectrum density for one cluster in DECIGO utilizing the quantum noise of one differential Fabry-Perot interferometer. Then we calculated the SNR by correlating two clusters in the same position. We performed the optimization for two cases: the constant mirror-thickness case and the constant mirror-mass case. As a result, we obtained the SNR dependence on the mirror radius, which also determines various DECIGO parameters. This result is the first step toward optimizing the DECIGO design by considering the practical constraints on the mirror dimension and implementing other noise sources.

gr-qc