Searcharxiv⌕ Search

arXiv subjects

Selim M. Shahriar

Publications and source records attributed to Selim M. Shahriar.

At least 37 records · Page 2Linked to original sources

Spin squeezing enhanced dual species atom interferometric accelerometer employing large momentum transfer for precision test of the equivalence principle

We theoretically investigate the feasibility of applying spin squeezing to a light pulse atom interferometer in the presence of large momentum transfer using off-resonant Raman transitions, in order to enhance the sensitivity of accelerometry close to the Heisenberg limit. We also show how to implement this scheme in a dual-species atom interferometer for precision test of the equivalence principle by measuring the Eotvos parameter, and identify the spin squeezing protocol that is best suited for such an experiment. For a space borne platform in low earth orbit, such a scheme may eventually enable the measurement of the Eotvos parameter with a sensitivity of the order of 10^(-20).

quant-ph↗

Ultrafast Image Retrieval from a Holographic Memory Disc for High-Speed Operation of a Shift, Scale, and Rotation Invariant Target Recognition System

The hybrid opto-electronic correlator (HOC) architecture has been shown to be able to detect matches in a shift, scale, and rotation invariant (SSRI) manner by incorporating a polar Mellin transform (PMT) pre-processing step. Here we demonstrate the design and use of a thick holographic memory disc (HMD) for high-speed SSRI correlation employing an HOC. The HMD was written to have 1,320 stored images, including both unprocessed images and their PMTs. We further propose and demonstrate a novel approach whereby the HOC inputs are spatially shifted to produce correlation signals without requiring stabilization of optical phases, yielding results that are in good agreement with the theory. Use of this approach vastly simplifies the design and operation of the HOC, while improving its stability significantly. Finally, a real-time opto-electronic PMT pre-processor utilizing an FPGA is proposed and prototyped, allowing for the automatic conversion of images into their PMTs without additional processing delay.

physics.optics↗

Rapid Generation of a Macroscopic Schrödinger Cat State of Atoms with Parity-Independent Orientation

We show that using the process of one-axis-twist squeezing in an echo configuration, it is possible to control the orientation of the macroscopic magnetic moment of a large number of atoms by manipulating the quantum state of a single atom that is physically isolated from the ensemble. With this control technique, it is also possible to entangle an ensemble with a single atom deterministically, which mimics the thought experiment known as the Schrödinger cat. In addition, this technique would make it possible to generate a mesoscopic Schrödinger cat state for a large number of atoms far more rapidly that the conventional process for generating such a state, with an orientation that is independent of the parity of the number of atoms. Apart from the echo configuration, we have also investigated the behavior of one-axis-twist squeezing for some special values of the squeezing parameter. We find that the squeezing propagator can be expressed as the sum of n rotation operators if the product of n and the squeezing parameter equals pi, where n is a non-zero integer. A direct consequence of this property of one-axis-twist squeezing is that there is a hidden order in a squeezed state generated under this condition even if its Husimi quasi-probability distribution looks irregular.

quant-ph↗

Spin Squeezing Induced Enhancement of Sensitivity of an Atomic Clock using Coherent Population Trapping

The coherent population trapping (CPT) effect is used for making compact atomic clocks. There are two types of CPT clocks: the one in which the Raman beams are applied continuously and the one in which two CPT pulses separated by a dark period are applied (Ramsey scheme). It is obvious that the technique of spin squeezing can only be applied to the Ramsey CPT clock to enhance the sensitivity. However, it is not apparent how to adapt to the CPT clock the protocols for the microwave clock using one-axis-twist squeezing (OATS), since the Ramsey CPT clock is not trivially equivalent to the Ramsey microwave clock. In this paper, we show explicitly how to adapt two protocols using OATS, namely the Schrödinger cat state protocol (SCSP) and the generalization thereof, and the echo squeezing protocol (ESP), to the CPT clock. The ESP magnifies the phase shift by a factor of the square-root of (N/e), while the SCSP magnifies the phase shift by a factor of N/2 , making it able to achieve a higher sensitivity in the presence of excess noise.

quant-ph↗

Multi-axis Accelerometry and Rotation Sensing using a Point Source Atom Interferometer

A point source atom interferometer (PSI) is a device where atoms are split and recombined by applying a temporal sequence of Raman pulses during the expansion of a cloud of cold atoms behaving approximately as a point source. Unlike a conventional light pulse atom interferometer, the PSI can produce a signal that corresponds to multi-axis rotation only, independent of acceleration. In addition, it can be used to measure acceleration along one direction, independent of rotation. Here, we describe a modified PSI that can be used to measure multi-axis rotation and multi-axis acceleration. Specifically, this type of PSI can be used to measure two-axes rotation around the directions perpendicular to the light pulses, as well as the acceleration in all three directions, with only one pair of Raman beams. Using two pairs of Raman beams in orthogonal directions sequentially, such a scheme would enable the realization of a complete atom interferometric inertial measurement unit.

physics.atom-ph↗

Beyond the Petermann limit: can exceptional points increase sensor precision?

Experiments near the lock-in region in maximally dissipative non-Hermitian systems, e.g., conventional laser gyroscopes near the deadband, have run up against the Petermann limit, where excess noise exactly cancels any scale-factor enhancement resulting in no overall enhancement in precision. As a result, one might be tempted to conclude that exceptional points (EPs) generally cannot be used to increase the precision of laser sensors. Indeed, using a linear eigenmode analysis we show that the Petermann limit applies not just to maximally dissipative systems, but for any type of EP, owing to the fact that EPs are rotationally invariant. It turns out, however, that this restriction comes from the assumption of linearity. We find that nonlinearity breaks the rotation symmetry such that the different types of EPs are no longer equivalent above threshold. In particular, for sufficiently high measurement frequencies, EPs in conservatively coupled systems having a saturation imbalance can lead to an increase in the fundamental precision beyond the Petermann limit. Importantly, we find that only one mode lases under these conditions. We show that the beat note can be recovered by interference with an auxiliary mode, but that this has consequences for the quantum and classical noise that depend on the recovery scheme. Thus, it remains to be seen whether practical experiments can be designed that can take advantage of this enhancement.

physics.optics↗

High sensitivity multi-axes rotation sensing using large momentum transfer point source atom interferometry

A point source interferometer (PSI) is a device where atoms are split and recombined by applying a temporal sequence of Raman pulses during the expansion of a cloud of cold atoms behaving approximately as a point source. The PSI can work as a sensitive multi-axes gyroscope that can automatically filter out the signal from accelerations. The phase shift arising from rotations is proportional to the momentum transferred to each atom from the Raman pulses. Therefore, by increasing the momentum transfer, it should be possibly to enhance the sensitivity of the PSI. Here, we investigate the degree of enhancement in sensitivity that could be achieved by augmenting the PSI with large momentum transfer (LMT) employing a sequence of many Raman pulses with alternating directions. Contrary to typical approaches used for describing a PSI, we employ a model under which the motion of the center of mass of each atom is described quantum mechanically. We show how increasing Doppler shifts lead to imperfections, thereby limiting the visibility of the signal fringes, and identify ways to suppress this effect by increasing the effective, two-photon Rabi frequencies of the Raman pulses. Taking into account the effect of spontaneous emission, we show that, for a given value of the one-photon Rabi frequency, there is an optimum value for the number of pulses employed, beyond which the net enhancement in sensitivity begins to decrease. For a one-photon Rabi frequency of 200 MHz, for example, the peak value of the factor of enhancement in sensitivity is ~39, for a momentum transfer that is ~69 times as large as that for a conventional PSI. We also find that this peak value scales as the one-photon Rabi frequency to the power of 4/5.

quant-ph↗

Enhancing Sensitivity of an Atom Interferometer to the Heisenberg Limit using Increased Quantum Noise

In a conventional atomic interferometer employing $N$ atoms, the phase sensitivity is at the standard quantum limit: $1/\sqrt{N}$. Using spin-squeezing, the sensitivity can be increased, either by lowering the quantum noise or via phase amplification, or a combination thereof. Here, we show how to increase the sensitivity, to the Heisenberg limit of $1/N$, while increasing the quantum noise by $\sqrt{N}$, thereby suppressing by the same factor the effect of excess noise. The protocol uses a Schrödinger Cat state representing a superposition of two collective states of $N$ atoms, behaving as a single entity with an $N$-fold increase in Compton frequency. The resulting $N$-fold phase magnification is revealed by using atomic state detection instead of collective state detection. We also show how to realize an atomic clock based on such a Schrödinger Cat state, with an $N$-fold increase in the effective transition frequency. We discuss potential experimental constraints for implementing this scheme, using one axis twist squeezing employing the cavity feedback scheme, and show that the effects of cavity decay and spontaneous emission are highly suppressed. We find that the maximum improvement in sensitivity can be close to the ideal limit, for as many as ten million atoms.

quant-ph↗

Ultra-high Compton Frequency, Parity Independent, Mesoscopic Schrödinger Cat Atom Interferometer with Heisenberg Limited Sensitivity

We present a protocol for an atomic interferometer that reaches the Heisenberg Limit (HL), within a factor of $\sim$ $\sqrt{2}$, via collective state detection and critical tuning of one-axis twist spin squeezing. It generates a Schrödinger cat (SC) state, as a superposition of two extremal collective states. When this SC interferometer is used as a gyroscope, the interference occurs at an ultrahigh Compton frequency, corresponding to a mesoscopic single object with a mass of $Nm$, where $N$ is the number of particles in the ensemble, and $m$ is the mass of each particle. For $^{87}$Rb atoms, with $N=10^{6}$, for example, the intereference would occur at a Compton frequency of $\sim$ $2 \times 10^{31}$ Hz. Under this scheme, the signal is found to depend critically on the parity of $N$. We present two variants of the protocol. Under Protocol A, the fringes are narrowed by a factor of $N$ for one parity, while for the other parity the signal is zero. Under Protocol B, the fringes are narrowed by a factor of $N$ for one parity, and by a factor of $\sqrt{N}$ for the other parity. Both protocols can be modified in a manner that reverses the behavior of the signals for the two parities. Over repeated measurements under which the probability of being even or odd is equal, the averaged sensitivity is smaller than the HL by a factor of $\sim$ $\sqrt{2}$ for both versions of the protocol. We show that when the SC interferometer is configured as an accelerometer, the effective two-photon wave vector is enhanced by a factor of $N$, leading to the same degree of enhancement in sensitivity. We also show that such a mesoscopic single object can be used to increase the effective base frequency of an atomic clock by a factor of $N$, with a sensitivity that is equivalent to the HL, within a factor of $\sim$ $\sqrt{2}$.

physics.atom-ph↗

Negative dispersion medium at 1064 nm in an optomechanical resonator for enhancing the sensitivity bandwidth in a gravitational-wave detector

Recently, we had proposed an optically-pumped five-level Gain EIT (GEIT) system, which has a transparency dip superimposed on a gain profile and exhibits a negative dispersion suitable for the white light cavity (WLC) enhanced interferometric gravitational wave detector [Phys. Rev. D. 92, 082002 (2015)]. Using this system as the negative dispersion medium (NDM) in the WLC-SR (signal recycling) scheme, we get an enhancement in the quantum noise (QN) limited sensitivity-bandwidth product by a factor of ~18. We have also shown how to realize such a system in practice using Zeeman sublevels in $^{87}$Rb at 795nm [Opt. Commun. 402, 382-388 (2017)]. However, aLIGO operates at 1064nm and suitable transitions in Rb or other alkali atoms are not available at this wavelength. Therefore, it is necessary to consider a system that is consistent with the operating wavelength of aLIGO. Here, we present the realization of such an NDM at 1064nm with a microresonator, which supports optomechanical interaction. A strong control field is applied at a higher frequency, and, under certain conditions, a probe field at a lower frequency experiences a peak at the center of an absorption profile, and a negative dispersion in the transmission. Unlike in the GEIT case, we use the compound-cavity signal-recycling (CC-SR) scheme, where an auxiliary mirror is inserted in the dark port of the detector, and show that the enhancement factor can be as high as ~15. However, using the parameters required for the sensitivity enhancement, the optomechanical system enters an instability region where the control field is depleted. We present an observer based feedback control process used to stabilize the CC-SR system.

gr-qc↗

Fast-light Enhanced Brillouin Laser Based Active Fiber Optics Sensor for Simultaneous Measurement of Rotation and Acceleration

We have developed a conceptual design for an Active Fast Light Fiber Optic Sensor (AFLIFOS) that can perform simultaneously or separately as a gyroscope (differential mode effect) and a sensor for acceleration, strain, and other common mode effects. Two Brillouin lasers in opposite directions and separated in frequency by several free spectral ranges are used for this sensor. By coupling two auxiliary resonators to the primary fiber resonator, we produce superluminal effects for two laser modes. We develop a detailed theoretical model for optimizing the design of the AFLIFOS, and show that the enhancement factor of the sensitivity is $\sim{187}$ and $\sim{-187}$, respectively for the two Brillouin lasers under the optimized condition, when the effective change in perimeter of the primary fiber resonator is 0.1nm, corresponding to a rotation rate of 0.4 deg/sec for a ring resonator with radius 1m. It may be possible to get much higher enhancement by adjusting the parameters such as the perimeters and the coupling coefficients.

physics.optics↗

Realization of Gain with Electromagnetically Induced Transparency System with Non-degenerate Zeeman Sublevels in $^{87}$Rb

Previously, we had proposed an optically-pumped five-level Gain EIT (GEIT) system, which has a transparency dip superimposed on a gain profile and exhibits a negative dispersion suitable for the white-light-cavity signal-recycling (WLC-SR) scheme of the interferometeric gravitational wave detector [Phys. Rev. D. 92, 082002 (2015)]. Using this system as the negative dispersion medium (NDM) in the WLC-SR, we get an enhancement in the quantum noise (QN) limited sensitivity-bandwidth product by a factor of ~18. Here, we show how to realize this GEIT system in a realistic platform, using non-degenerate Zeeman sublevels in alkali atoms. Specifically we choose $^{87}$Rb atoms, which produce the negative dispersion around 795nm. The current LIGO operates at 1064nm but future LIGO may operate at a wavelength that is consistent with this atomic system. We present a theoretical analysis for the susceptibilities of the system. To account for the QN from the GEIT system, it is necessary to use the master equation (ME) approach. However, due to the number of energy levels involved, applying the full ME approach to this system is very complex. We have also shown earlier, in the reference cited above, that under GEIT condition, the net enhancement in the sensitivity-bandwidth product, as predicted by the ME, is close to that predicted by applying the Caves model for a phase-insensitive linear amplifier. Therefore we here use the Caves model for the QN from the NDM and this simplified numerical model shows that the enhancement of the sensitivity-bandwidth product as high as 17 is possible.

physics.ins-det↗

All Optical Three Dimensional Spatio-Temporal Correlator for Automatic Event Recognition Using a Multiphoton Atomic System

We describe an automatic event recognition (AER) system based on a three-dimensional spatio-temporal correlator (STC) that combines the techniques of holographic correlation and photon echo based temporal pattern recognition. The STC is shift invariant in space and time. It can be used to recognize rapidly an event (e.g., a short video clip) that may be present in a large video file, and determine the temporal location of the event. Using polar Mellin transform, it is possible to realize an STC that is also scale and rotation invariant spatially. Numerical simulation results of such a system are presented using quantum mechanical equations of evolution. For this simulation we have used the model of an idealized, decay-free two level system of atoms with an inhomogeneous broadening that is larger than the inverse of the temporal resolution of the data stream. We show how such a system can be realized by using a lambda-type three level system in atomic vapor, via adiabatic elimination of the intermediate state. We have also developed analytically a three dimensional transfer function of the system, and shown that it agrees closely with the results obtained via explicit simulation of the atomic response. The analytical transfer function can be used to determine the response of an STC very rapidly. In addition to the correlation signal, other nonlinear terms appear in the explicit numerical model. These terms are also verified by the analytical model. We describe how the AER can be operated in a manner such that the correlation signal remains unaffected by the additional nonlinear terms. We also show how such a practical STC can be realized using a combination of a porous-glass based Rb vapor cell, a holographic video disc, and a lithium niobate crystal.

physics.optics↗

Catastrophic breakdown of the Caves model for quantum noise in some phase-insensitive linear amplifiers or attenuators based on atomic systems

When considering the effect of quantum noise (QN) in a phase-insensitive linear amplifier or attenuator, it is customary to use the single channel Caves model (SC-CM). Although this model is valid in simple situations, such as the presence of a beam splitter, it is not necessarily valid when a system with many degrees of freedom is involved. In order to address this issue, we consider in this paper various atomic transitions corresponding to amplification or attenuation using the master-equation- (ME-) based approach to model the QN and to compare the results with the SC-CM. For a four-level system that consists of a transition producing a broad gain peak and a transition producing an absorption dip, which results in perfect transparency at the center, we observe a catastrophic breakdown of the SC-CM. We also show that for a general two-level atomic system, the SC-CM does not apply, except in the limiting case when only either amplification or attenuation exists. A special case where the two models predict the same result is a Λ-type three-level electromagnetically induced transparency (EIT) system in which the QN at zero detuning vanishes while the system is in the dark state. We also study an optically pumped five-level gain EIT system which has a perfect transparency dip superimposed on a gain profile, and yields the negative dispersion suitable for use in enhancing the sensitivity-bandwidth product of an interferometric gravitational wave detector. In this case, we find that, for some set of parameters, the QN is vanishingly small at the center of the dip, and the SC-CM agrees closely with the ME model. However, we also find that for some other set of parameters, the SC-SM model disagrees strongly with the ME model. All these cases illustrate a wide range of variations in the degree of disagreement between the predictions of the SC-CM and the ME approaches.

physics.atom-ph↗

An N-atom Collective State Atomic Interferometer with Ultra-High Compton Frequency and Ultra-Short de Broglie Wavelength, with root-N Reduction in Fringe Width

We describe a collective state atomic interferometer (COSAIN) with the signal fringe as a function of phase-difference or rotation narrowed by $\sqrt{N}$ compared to a conventional interferometer - $N$ being the number of atoms - without entanglement. This effect arises from the interferences among collective states, and is a manifestation of interference at a Compton frequency of ten nonillion Hz, or a de Broglie wavelength of ten attometer, for $N=10^6$ and $v = 300 m/s$. The population of the collective state of interest is detected by a null measurement scheme, in which an event corresponding to detection of zero photons corresponds to the system being in that particular collective state. The signal is detected by collecting fluorescence through stimulated Raman scattering of Stokes photons, which are emitted predominantly against the direction of the probe beam, for a high enough resonant optical density. The sensitivity of the ideal COSAIN is found to be given by the standard quantum limit. However, when detection efficiency and collection efficiency are taken into account, the detection scheme of the COSAIN increases the quantum efficiency of detection significantly in comparison to a typical conventional Raman atomic interferometer employing fluorescence detection, yielding a net improvement in stability by as much as a factor of $10$. We discuss how the inhomogeneities arising from the non-uniformity in experimental parameters affect the COSAIN signal. We also describe an alternate experimental scheme to enhance resonant optical density in a COSAIN by using cross-linearly polarized counter-propagating Raman beams.

physics.atom-ph↗

Quantum noise limits in white-light-cavity-enhanced gravitational wave detectors

Previously, we had proposed a gravitational wave detector that incorporates the white-light-cavity (WLC) effect using a compound cavity for signal recycling (CC-SR). Here, we first use an idealized model for the negative dispersion medium (NDM) and use the so-called Caves model for a phase-insensitive linear amplifier to account for the quantum noise (QN) contributed by the NDM, in order to determine the upper bound of the enhancement in the sensitivity-bandwidth product. We calculate the quantum noise limited sensitivity curves for the CC-SR design, and find that the broadening of sensitivity predicted by the classical analysis is also present in these curves, but is somewhat reduced. Furthermore, we find that the curves always stay above the standard quantum limit. To circumvent this limitation, we modify the dispersion to compensate the non-linear phase variation produced by the optomechanical resonance effects. We find that the upper bound of the factor by which the sensitivity-bandwidth product is increased, compared to the highest-sensitivity result predicted by Bunanno and Chen [Phys. Rev. D 64, 042006 (2001)], is ~14. We also present a simpler scheme (WLC-SR) where a dispersion medium is inserted into the SR cavity. For this scheme, we found the upper bound of the enhancement factor to be ~18. We then consider an explicit system for realizing the NDM, which makes use of five energy levels in M-configuration to produce gain, accompanied by electromagnetically induced transparency (the GEIT system). For this explicit system, we employ the rigorous approach based on Master Equation to compute the QN contributed by the NDM, thus enabling us to determine the enhancement in the sensitivity-bandwidth product definitively rather than the upper bound thereof. Specifically, we identify a set of parameters for which the sensitivity-bandwidth product is enhanced by a factor of 17.66.

gr-qc↗

Modeling and analysis of an ultra-stable subluminal laser

We describe a subluminal laser which is extremely stable against perturbations. It makes use of a composite gain spectrum consisting of a broad background along with a narrow peak. The stability of the laser, defined as the change in frequency as a function of a change in the cavity length, is enhanced by a factor given by the group index, which can be as high as 105 for experimentally realizable parameters. We also show that the fundamental linewidth of such a laser is expected to be smaller by the same factor. We first present an analysis where the gain profile is modeled as a superposition of two Lorentzian functions. We then present a numerical study based on a physical scheme for realizing the composite gain profile. In this scheme, the broad gain is produced by a high pressure buffer-gas loaded cell of rubidium vapor. The narrow gain is produced by using a Raman pump in a second rubidium vapor cell, where optical pumping is used to produce a Raman population inversion. We show close agreement between the idealized model and the explicit model. A subluminal laser of this type may prove to be useful for many applications.

physics.optics↗

An N-atom Collective State Atomic Clock with Root-N Fold Increase in Effective Frequency and Root-N Fold Reduction in Fringe Width

We describe a collective state atomic clock with Ramsey fringes narrowed by a factor of $\sqrt{N}$ compared to a conventional clock, N being the number of non-interacting atoms, without violating the uncertainty relation. This narrowing is explained as being due to interferences among the collective states, representing an effective $\sqrt{N}$ fold increase in the clock frequency, without entanglement. The detection process, which measures a collective state, can be used to increase the quantum efficiency of detection significantly, yielding a net improvement in stability by as much as a factor of 10.

physics.atom-ph↗