SearcharxivSearch

arXiv subjects

Semih Kurt

Publications and source records attributed to Semih Kurt.

3 recordsLinked to original sources

Cooperation in the Latent Space: The Benefits of Adding Mixture Components in Variational Autoencoders

In this paper, we show how the mixture components cooperate when they jointly adapt to maximize the ELBO. We build upon recent advances in the multiple and adaptive importance sampling literature. We then model the mixture components using separate encoder networks and show empirically that the ELBO is monotonically non-decreasing as a function of the number of mixture components. These results hold for a range of different VAE architectures on the MNIST, FashionMNIST, and CIFAR-10 datasets. In this work, we also demonstrate that increasing the number of mixture components improves the latent-representation capabilities of the VAE on both image and single-cell datasets. This cooperative behavior motivates that using Mixture VAEs should be considered a standard approach for obtaining more flexible variational approximations. Finally, Mixture VAEs are here, for the first time, compared and combined with normalizing flows, hierarchical models and/or the VampPrior in an extensive ablation study. Multiple of our Mixture VAEs achieve state-of-the-art log-likelihood results for VAE architectures on the MNIST and FashionMNIST datasets. The experiments are reproducible using our code, provided here: https://github.com/lagergren-lab/mixturevaes.

cs.LG

Rapid TAURUS for Relaxation-Based Color Magnetic Particle Imaging

Magnetic particle imaging (MPI) is a rapidly developing medical imaging modality that exploits the non-linear response of magnetic nanoparticles (MNPs). Color MPI widens the functionality of MPI, empowering it with the capability to distinguish different MNPs and/or MNP environments. The system function approach for color MPI relies on extensive calibrations that capture the differences in the harmonic responses of the MNPs. An alternative calibration-free x-space-based method called TAURUS estimates a map of the relaxation time constant, by recovering the underlying mirror symmetry in the MPI signal. However, TAURUS requires a back and forth scanning of a given region, restricting its usage to slow trajectories with constant or piecewise constant focus fields (FFs). In this work, we propose a novel technique to increase the performance of TAURUS and enable $\tau$ map estimation for rapid and multi-dimensional trajectories. The proposed technique is based on correcting the mirror symmetry distortion induced by time-varying FFs. We demonstrate via simulations and experiments in our in-house MPI scanner that the proposed method successfully estimates high-fidelity time constant maps for rapid trajectories that provide orders of magnitude reduction in scanning time while preserving the calibration-free property of TAURUS.

eess.SP

Partial FOV Center Imaging (PCI): A Robust X-Space Image Reconstruction for Magnetic Particle Imaging

Magnetic Particle Imaging (MPI) is an emerging medical imaging modality that images the spatial distribution of superparamagnetic iron oxide (SPIO) nanoparticles using their nonlinear response to applied magnetic fields. In standard x-space approach to MPI, the image is reconstructed by gridding the speed-compensated nanoparticle signal to the instantaneous position of the field free point (FFP). However, due to safety limits on the drive field, the field-of-view (FOV) needs to be covered by multiple relatively small partial field-of-views (pFOVs). The image of the entire FOV is then pieced together from individually processed pFOVs. These processing steps can be sensitive to non-ideal signal conditions such as harmonic interference, noise, and relaxation effects. In this work, we propose a robust x-space reconstruction technique, Partial FOV Center Imaging (PCI), with substantially simplified pFOV processing. PCI first forms a raw image of the entire FOV by mapping MPI signal directly to pFOV center locations. The corresponding MPI image is then obtained by deconvolving this raw image by a fully known, compact kernel, which solely depends on the pFOV size. We analyze the performance of the proposed reconstruction via extensive simulations, as well as imaging experiments on our in-house FFP MPI scanner. The results show that PCI offers a trade-off between noise robustness and interference robustness, outperforming standard x-space reconstruction in terms of both robustness against non-ideal signal conditions and image quality.

physics.med-ph