SearcharxivSearch

arXiv subjects

Sepehr Ahmadi

Publications and source records attributed to Sepehr Ahmadi.

5 recordsLinked to original sources

Method for real-time monitoring of paramagnetic reactions using spin relaxometry with fluorescent nanodiamonds

Spin relaxometry using fluorescent nanodiamonds (FNDs) has been applied successfully to sense numerous paramagnetic target molecules such as free radicals and metalloproteins. However, despite their high sensitivity, T1 spin relaxation measurements are often hampered by their slow acquisition speed. Here, we demonstrate a method that allows for real-time monitoring of paramagnetic chemical reactions. We demonstrate T1 spin relaxometry from thousands of FNDs using an optimised cuvette-based system integrating an avalanche photodiode operated in linear mode, and a fast, fieldprogrammable gate array (FPGA) for data collation. We demonstrate chemical monitoring of the reduction of Cu(II) to Cu(I) ions in-solution with a 15 second integration using an optimised T1 sensing protocol. Our method achieves more than two orders of magnitude speed up with an order of magnitude reduction in cost when compared with traditional techniques. With further technical improvements, we believe this in-solution method could be extended to sense the sub-second chemical kinetics of paramagnetic molecules in solution.

cond-mat.mes-hall

A method for robust spin relaxometry in the presence of imperfect state preparation

Spin relaxometry based on quantum spin systems has developed as a valuable tool in medical and condensed matter systems, offering the advantage of operating without the need for external DC or RF fields. Spin relaxometry with nitrogen-vacancy (NV) centers has been applied to paramagnetic sensing using both single crystal diamond and nanodiamond materials. However, these methods often suffer from artifacts and systematic uncertainties, particularly due to imperfect spin state preparation, leading to artificially fast T$_1$ relaxation times. Current analysis techniques fail to adequately account for these issues, limiting the precision of parameter estimation. In this work, we introduce a minimal fitting procedure that enables more robust parameter estimation in the presence of imperfect spin polarization. Our model improves upon existing approaches by offering more accurate fits and provides a framework for efficiently parallelizing single-spin dynamics studies.

quant-ph

Nitrogen-Vacancy Ensemble Magnetometry Based on Pump Absorption

We demonstrate magnetic field sensing using an ensemble of nitrogen-vacancy centers by recording the variation in the pump-light absorption due to the spin-polarization dependence of the total ground state population. Using a 532 nm pump laser, we measure the absorption of native nitrogen-vacancy centers in a chemical vapor deposited diamond placed in a resonant optical cavity. For a laser pump power of 0.4 W and a cavity finesse of 45, we obtain a noise floor of $\sim$ 100 nT/$\sqrt{\textrm{Hz}}$ spanning a bandwidth up to 125 Hz. We project a photon shot-noise-limited sensitivity of $\sim$ 1 pT/$\sqrt{\textrm{Hz}}$ by optimizing the nitrogen-vacancy concentration and the detection method.

quant-ph

Pump-Enhanced Continuous-Wave Magnetometry using Nitrogen-Vacancy Ensembles

Ensembles of nitrogen-vacancy centers in diamond are a highly promising platform for high-sensitivity magnetometry, whose efficacy is often based on efficiently generating and monitoring magnetic-field dependent infrared fluorescence. Here we report on an increased sensing efficiency with the use of a 532-nm resonant confocal cavity and a microwave resonator antenna for measuring the local magnetic noise density using the intrinsic nitrogen-vacancy concentration of a chemical-vapor deposited single-crystal diamond. We measure a near-shot-noise-limited magnetic noise floor of 200 pT/$\sqrt{\text{Hz}}$ spanning a bandwidth up to 159 Hz, and an extracted sensitivity of approximately 3 nT/$\sqrt{\text{Hz}}$, with further enhancement limited by the noise floor of the lock-in amplifier and the laser damage threshold of the optical components. Exploration of the microwave and optical pump-rate parameter space demonstrates a linewidth-narrowing regime reached by virtue of using the optical cavity, allowing an enhanced sensitivity to be achieved, despite an unoptimized collection efficiency of <2 %, and a low nitrogen-vacancy concentration of about 0.2 ppb.

quant-ph

Optimised frequency modulation for continuous-wave optical magnetic resonance sensing using nitrogen-vacancy ensembles

Magnetometers based on ensembles of nitrogen-vacancy centres are a promising platform for continuously sensing static and low-frequency magnetic fields. Their combination with phase-sensitive (lock-in) detection creates a highly versatile sensor with a sensitivity that is proportional to the derivative of the optical magnetic resonance lock-in spectrum, which is in turn dependant on the lock-in modulation parameters. Here we study the dependence of the lock-in spectral slope on the modulation of the spin-driving microwave field. Given the presence of the intrinsic nitrogen hyperfine spin transitions, we experimentally show that when the ratio between the hyperfine linewidth and their separation is $\gtrsim 1/4$, square-wave based frequency modulation generates the steepest slope at modulation depths exceeding the separation of the hyperfine lines, compared to sine-wave based modulation. We formulate a model for calculating lock-in spectra which shows excellent agreement with our experiments, and which shows that an optimum slope is achieved when the linewidth/separation ratio is $\lesssim 1/4$ and the modulation depth is less then the resonance linewidth, irrespective of the modulation function used.

physics.ins-det