Searcharxiv⌕ Search

arXiv subjects

Sergey V. Molkov

Publications and source records attributed to Sergey V. Molkov.

21 records · Page 2Linked to original sources

Basic parameters of the helium accreting X-ray bursting neutron star in 4U 1820-30

The ultracompact low-mass X-ray binary 4U 1820-30 situated in the globular cluster NGC 6624 has an orbital period of only $\approx$11.4 min which likely implies a white dwarf companion. The observed X-ray bursts demonstrate a photospheric radius expansion phase and therefore are believed to reach the Eddington luminosity allowing us to estimate the mass and the radius of the neutron star (NS) in this binary. Here we re-analyse all Rossi X-ray Timing Explorer observations of the system and confirm that almost all the bursts took place during the hard persistent state of the system. This allows us to use the recently developed direct cooling tail method to estimate the NS mass and radius. However, because of the very short, about a second, duration of the cooling tail phases that can be described by the theoretical atmosphere models, the obtained constraints on the NS radius are not very strict. Assuming a pure helium NS atmosphere we found that the NS radius is in the range 10-12 km, if the NS mass is below 1.7 $M_\odot$, and in a wider range of 8-12 km for a higher 1.7-2.0 $M_\odot$ NS mass. The method also constrains the distance to the system to be 6.5$\pm$0.5 kpc, which is consistent with the distance to the cluster. For the solar composition atmosphere, the NS parameters are in strong contradiction with the generally accepted range of possible NS masses and radii.

astro-ph.HE↗

NuSTAR discovery of a cyclotron absorption line in the transient X-ray pulsar 2S 1553-542

We report results of a spectral and timing analysis of the poorly studied transient X-ray pulsar 2S 1553-542 using data collected with the NuSTAR and Chandra observatories and the Fermi/GBM instrument during an outburst in 2015. Properties of the source at high energies (>30 keV) are studied for the first time and the sky position had been essentially improved. The source broadband spectrum has a quite complicated shape and can be reasonably described by a composite model with two continuum components - a black body emission with the temperature about 1 keV at low energies and a power law with an exponential cutoff at high energies. Additionally an absorption feature at $\sim23.5$ keV is discovered both in phase-averaged and phase-resolved spectra and interpreted as the cyclotron resonance scattering feature corresponding to the magnetic field strength of the neutron star $B\sim3\times10^{12}$ G. Based on the Fermi/GBM data the orbital parameters of the system were substantially improved, that allowed us to determine the spin period of the neutron star P = 9.27880(3) s and a local spin-up $\dot P \simeq -7.5\times10^{-10}$ s s$^{-1}$ due to the mass accretion during the NuSTAR observations. Assuming accretion from the disk and using standard torque models we have estimated the distance to the system $d=20\pm4$ kpc.

astro-ph.HE↗

Search for photon bubble oscillations in V0332+53

We report results of our search for fast oscillations in lightcurve of one of the brightest accretion powered pulsars on the sky V0332+53 with the help of data of the PCA spectrometer of the RXTE observatory. In course of this search we have carefully explored complications appearing if one uses only sub-bands of the total bandpass of the PCA spectrometer. We show that lightcurves collected in the soft sub-band of the PCA spectrometer contains an additional instrumental noise, lightcurves of harder sub-bands lack some fraction of the anticipated Poisson noise. We show that this noise is caused by a cross-talk of energy bands, which lasts up to ~200usec. One hypothesis is that these effects are caused by temporarily drop of the PCA detector gain after any occurred event due to slowly moving ions in the detector volume. In order to avoid this effect we searched for fast oscillations in flux of V0332+53 only in the total bandpass of the PCA spectrometer 2-60 keV. We have not detected any quasi-periodic oscillations in lightcurve of the source with an upper limit at the level of 0.5% in the Fourier frequency range 200-1500 Hz.

astro-ph.HE↗