Searcharxiv⌕ Search

arXiv subjects

Sergio G. Leon-Saval

Publications and source records attributed to Sergio G. Leon-Saval.

14 recordsLinked to original sources

Astrophotonics -- current capabilities and the road ahead

Astrophotonics represents a cutting-edge approach in observational astronomy. This paper explores the significant advancements and potential applications of astrophotonics, highlighting how photonic technologies stand to revolutionise astronomical instrumentation. Key areas of focus include photonic wavefront sensing and imaging, photonic interferometry and nulling, advanced chip fabrication methods, and the integration of spectroscopy and sensing onto photonic chips. The role of single-mode fibres in reducing modal noise, and the development of photonic integral field units (IFUs) and arrayed waveguide gratings (AWGs) for high-resolution, spatially resolved spectroscopy will be examined. As part of the Sydney regional-focus issue, this review aims to detail some of the current technological achievements in this field as well as to discuss the future trajectory of astrophotonics, underscoring its potential to unlock important new astronomical discoveries.

astro-ph.IM↗

Learning the Lantern: Neural network applications to broadband photonic lantern modelling

Photonic lanterns allow the decomposition of highly multimodal light into a simplified modal basis such as single-moded and/or few-moded. They are increasingly finding uses in astronomy, optics and telecommunications. Calculating propagation through a photonic lantern using traditional algorithms takes $\sim 1$ hour per simulation on a modern CPU. This paper demonstrates that neural networks can bridge the disparate opto-electronic systems, and when trained can achieve a speed-up of over 5 orders of magnitude. We show that this approach can be used to model photonic lanterns with manufacturing defects as well as successfully generalising to polychromatic data. We demonstrate two uses of these neural network models, propagating seeing through the photonic lantern as well as performing global optimisation for purposes such as photonic lantern funnels and photonic lantern nullers.

physics.optics↗

3D-M3: High-spatial resolution spectroscopy with extreme AO and 3D printed micro-lenslets

By combining IFS with ExAO we are now able to resolve objects close to the diffraction-limit of large telescopes, exploring new science cases. We introduce an IFU designed to couple light with a minimal platescale from the SCExAO facility at NIR wavelengths to a SM spectrograph. The IFU has a 3D-printed MLA on top of a custom SM MCF, to optimize the coupling of light into the fiber cores. We demonstrate the potential of the instrument via initial results from the first on-sky runs at the 8.2 m Subaru Telescope with a spectrograph using off-the-shelf optics, allowing for rapid development with low cost.

astro-ph.IM↗

All-fiber photonic lantern multimode optical receiver with coherent adaptive optics beam combining

A multimode optical receiver for free space optical communications (FSOC) based on a photonic lantern and adaptive optics coherent beam combining (CBC) of the lantern's single-mode outputs is proposed and demonstrated for the first time. The use of optical coherent combining in fiber serves to increase the signal to noise ratio compared to similar receivers based on electrically combined signals, and represents an all-fiber approach to low-order adaptive optics. This optical receiver is demonstrated using a photonic lantern with three outputs, fibre couplers and active phase locking, and further investigated under atmospheric conditions with and without turbulence.

physics.optics↗

An innovative integral field unit upgrade with 3D-printed micro-lenses for the RHEA at Subaru

In the new era of Extremely Large Telescopes (ELTs) currently under construction, challenging requirements drive spectrograph designs towards techniques that efficiently use a facility's light collection power. Operating in the single-mode (SM) regime, close to the diffraction limit, reduces the footprint of the instrument compared to a conventional high-resolving power spectrograph. The custom built injection fiber system with 3D-printed micro-lenses on top of it for the replicable high-resolution exoplanet and asteroseismology spectrograph at Subaru in combination with extreme adaptive optics of SCExAO, proved its high efficiency in a lab environment, manifesting up to ~77% of the theoretical predicted performance.

astro-ph.IM↗

An all-photonic focal-plane wavefront sensor

Adaptive optics (AO) is critical in astronomy, optical communications and remote sensing to deal with the rapid blurring caused by the Earth's turbulent atmosphere. But current AO systems are limited by their wavefront sensors, which need to be in an optical plane non-common to the science image and are insensitive to certain wavefront-error modes. Here we present a wavefront sensor based on a photonic lantern fibre-mode-converter and deep learning, which can be placed at the same focal plane as the science image, and is optimal for single-mode fibre injection. By measuring the intensities of an array of single-mode outputs, both phase and amplitude information on the incident wavefront can be reconstructed. We demonstrate the concept with simulations and an experimental realisation wherein Zernike wavefront errors are recovered from focal-plane measurements to a precision of $5.1\times10^{-3}\;π$ radians root-mean-squared-error.

astro-ph.IM↗

A Multi-Core Fibre Photonic Lantern Based Spectrograph for Raman Spectroscopy

We report on the development of a compact (volume $\approx$ 100\:cm$^3$), multimode diffraction-limited Raman spectrograph and probe designed to be compact as possible. The spectrograph uses `off the shelf' optics, a custom 3D-printed two-part housing and harnesses a multi-core fibre (MCF) photonic lantern (multimode to few-mode converter), which slices a large 40~\textmu m multimode input into a near-diffraction-limited 6~\textmu m aperture. Our unique design utilises the hexagonal geometry of our MCF, permitting high multimode collection efficiency with near-diffraction-limited performance in a compact design. Our approach does not require a complex reformatter or mask and thus preserves spectral information and throughput when forming the entrance slit of the spectrograph. We demonstrate the technology over the interval 800~nm to 940~nm (200~cm$^{-1}$ to 2000~cm$^{-1}$) with a resolution of 0.3\:nm (4\:cm$^{-1}$), but other spectral regions and resolutions from the UV to the near infrared are also possible. We demonstrate the performance of our system by recording the Raman spectra of several compounds, including the pharmaceuticals paracetamol and ibuprofen.

physics.ins-det↗

The SAMI Galaxy Survey: Data Release One with Emission-line Physics Value-Added Products

We present the first major release of data from the SAMI Galaxy Survey. This data release focuses on the emission-line physics of galaxies. Data Release One includes data for 772 galaxies, about 20% of the full survey. Galaxies included have the redshift range 0.004 < z < 0.092, a large mass range (7.6 < log(Mstellar/M$_\odot$) < 11.6), and star-formation rates of 10^-4 to 10^1\ M$_\odot$/yr. For each galaxy, we include two spectral cubes and a set of spatially resolved 2D maps: single- and multi-component emission-line fits (with dust extinction corrections for strong lines), local dust extinction and star-formation rate. Calibration of the fibre throughputs, fluxes and differential-atmospheric-refraction has been improved over the Early Data Release. The data have average spatial resolution of 2.16 arcsec (FWHM) over the 15~arcsec diameter field of view and spectral (kinematic) resolution R=4263 (sigma=30km/s) around Halpha. The relative flux calibration is better than 5\% and absolute flux calibration better than $\pm0.22$~mag, with the latter estimate limited by galaxy photometry. The data are presented online through the Australian Astronomical Observatory's Data Central.

astro-ph.GA↗

Beating the classical limit: A diffraction-limited spectrograph for an arbitrary input beam

We demonstrate a new approach to classical fiber-fed spectroscopy. Our method is to use a photonic lantern that converts an arbitrary (e.g. incoherent) input beam into N diffraction-limited outputs. For the highest throughput, the number of outputs must be matched to the total number of unpolarized spatial modes on input. This approach has many advantages: (i) after the lantern, the instrument is constructed from 'commercial off the shelf' components; (ii) the instrument is the minimum size and mass configuration at a fixed resolving power and spectral order (~shoebox sized in this case); (iii) the throughput is better than 60% (slit to detector, including detector QE of ~80%); (iv) the scattered light at the detector can be less than 0.1% (total power). Our first implementation operates over 1545-1555 nm (limited by the detector, a 640$\times$512 array with 20$μ$m pitch) with a spectral resolution of 0.055nm (R~30,000) using a 1$\times$7 (1 multi-mode input to 7 single-mode outputs) photonic lantern. This approach is a first step towards a fully integrated, multimode photonic microspectrograph.

astro-ph.IM↗

GNOSIS: the first instrument to use fibre Bragg gratings for OH suppression

GNOSIS is a prototype astrophotonic instrument that utilizes OH suppression fibres consisting of fibre Bragg gratings and photonic lanterns to suppress the 103 brightest atmospheric emission doublets between 1.47-1.7 microns. GNOSIS was commissioned at the 3.9-meter Anglo-Australian Telescope with the IRIS2 spectrograph to demonstrate the potential of OH suppression fibres, but may be potentially used with any telescope and spectrograph combination. Unlike previous atmospheric suppression techniques GNOSIS suppresses the lines before dispersion and in a manner that depends purely on wavelength. We present the instrument design and report the results of laboratory and on-sky tests from commissioning. While these tests demonstrated high throughput and excellent suppression of the skylines by the OH suppression fibres, surprisingly GNOSIS produced no significant reduction in the interline background and the sensitivity of GNOSIS and IRIS2 is about the same as IRIS2. It is unclear whether the lack of reduction in the interline background is due to physical sources or systematic errors as the observations are detector noise-dominated. OH suppression fibres could potentially impact ground-based astronomy at the level of adaptive optics or greater. However, until a clear reduction in the interline background and the corresponding increasing in sensitivity is demonstrated optimized OH suppression fibres paired with a fibre-fed spectrograph will at least provide a real benefits at low resolving powers.

astro-ph.IM↗

The nature of the near-infrared interline sky background using fibre Bragg grating OH suppression

We analyse the near-infrared interline sky background, OH and O2 emission in 19 hours of H band observations with the GNOSIS OH suppression unit and the IRIS2 spectrograph at the 3.9-m AAT. We find that the temporal behaviour of OH emission is best described by a gradual decrease during the first half of the night followed by a gradual increase during the second half of the night following the behaviour of the solar elevation angle. We measure the interline background at 1.520 microns where the instrumental thermal background is very low and study its variation with zenith distance, time after sunset, ecliptic latitude, lunar zenith angle and lunar distance to determine the presence of non-thermal atmospheric emission, zodiacal scattered light and scattered moonlight. Zodiacal scattered light is too faint to be detected in the summed observations. Scattered moonlight due to Mie scattering by atmospheric aerosols is seen at small lunar distances (< 11 deg), but is otherwise too faint to detect. Except at very small lunar distances the interline background at a resolving power of R~2400 when using OH suppression fibres is dominated by a non-thermal atmospheric source with a temporal behaviour that resembles atmospheric OH emission suggesting that the interline background contains instrumentally-scattered OH. However, the interline background dims more rapidly than OH early in the night suggesting contributions from rapid dimming molecules. The absolute interline background is 560 +/- 120 photons s^-1 m^-2 micron^-1 arcsec^-2 under dark conditions. This value is similar to previous measurements without OH suppression suggesting that non-suppressed atmospheric emission is responsible for the interline background. Future OH suppression fibre designs may address this by the suppression of more sky lines using more accurate sky line measurements taken from high resolution spectra.

astro-ph.IM↗

Single mode, extreme precision Doppler spectrographs

The 'holy grail' of exoplanet research today is the detection of an earth-like planet: a rocky planet in the habitable zone around a main-sequence star. Extremely precise Doppler spectroscopy is an indispensable tool to find and characterize earth-like planets; however, to find these planets around solar-type stars, we need nearly one order of magnitude better radial velocity (RV) precision than the best current spectrographs provide. Recent developments in astrophotonics (Bland-Hawthorn & Horton 2006, Bland-Hawthorn et al. 2010) and adaptive optics (AO) enable single mode fiber (SMF) fed, high resolution spectrographs, which can realize the next step in precision. SMF feeds have intrinsic advantages over multimode fiber or slit coupled spectrographs: The intensity distribution at the fiber exit is extremely stable, and as a result the line spread function of a well-designed spectrograph is fully decoupled from input coupling conditions, like guiding or seeing variations (Ihle et al. 2010). Modal noise, a limiting factor in current multimode fiber fed instruments (Baudrand & Walker 2001), can be eliminated by proper design, and the diffraction limited input to the spectrograph allows for very compact instrument designs, which provide excellent optomechanical stability. A SMF is the ideal interface for new, very precise wavelength calibrators, like laser frequency combs (Steinmetz et al. 2008, Osterman et al. 2012), or SMF based Fabry-Perot Etalons (Halverson et al. 2012). At near infrared wavelengths, these technologies are ready to be implemented in on-sky instruments, or already in use. We discuss a novel concept for such a spectrograph.

astro-ph.IM↗

First Science with SAMI: A Serendipitously Discovered Galactic Wind in ESO 185-G031

We present the first scientific results from the Sydney-AAO Multi-Object IFS (SAMI) at the Anglo-Australian Telescope. This unique instrument deploys 13 fused fibre bundles (hexabundles) across a one-degree field of view allowing simultaneous spatially-resolved spectroscopy of 13 galaxies. During the first SAMI commissioning run, targeting a single galaxy field, one object (ESO 185-G031) was found to have extended minor axis emission with ionisation and kinematic properties consistent with a large-scale galactic wind. The importance of this result is two-fold: (i) fibre bundle spectrographs are able to identify low-surface brightness emission arising from extranuclear activity; (ii) such activity may be more common than presently assumed because conventional multi-object spectrographs use single-aperture fibres and spectra from these are nearly always dominated by nuclear emission. These early results demonstrate the extraordinary potential of multi-object hexabundle spectroscopy in future galaxy surveys.

astro-ph.GA↗

The Photonic TIGER: a multicore fiber-fed spectrograph

We present a proof of concept compact diffraction limited high-resolution fiber-fed spectrograph by using a 2D multicore array input. This high resolution spectrograph is fed by a 2D pseudo-slit, the Photonic TIGER, a hexagonal array of near-diffraction limited single-mode cores. We study the feasibility of this new platform related to the core array separation and rotation with respect to the dispersion axis. A 7 core compact Photonic TIGER fiber-fed spectrograph with a resolving power of around R~31000 and 8 nm bandwidth in the IR centered on 1550 nm is demonstrated. We also describe possible architectures based on this concept for building small scale compact diffraction limited Integral Field Spectrographs (IFS).

astro-ph.IM↗