Object independent scatter sensitivities for PET, applied to scatter estimation through fast Monte Carlo simulation

Scattered coincidences introduce quantitative bias in positron emission tomography (PET) and must be compensated during reconstruction. Conventional scatter estimates typically rely on simplified cylindrical scanner models that omit detector physics. Incorporating detector sensitivities for scatter is challenging because scattered events exhibit less constrained properties, such as incidence angles, compared to true coincidences. We integrated a 5D single-photon detection probability lookup table (LUT) accounting for photon energy, incidence angle, and detector location into the simulator logic. The resulting scatter sinogram is scaled by a precomputed, LUT-specific scatter sensitivity sinogram. Scatter was simulated using MCGPU-PET, a fast Monte Carlo (MC) simulator with a simplified scanner model, and applied to phantom data from a simulated GE Signa PET/MR in GATE. We evaluated three scenarios: (1) high-count MC simulations from a known activity distribution; (2) limited-count simulations; and (3) joint estimation of activity and scatter under low-count conditions. The method was also tested on two real Signa PET/MR acquisitions. In scenario 1, scatter-compensated reconstructions achieved <1% global bias in all active regions. In scenario 2, noisy scatter estimates caused positive bias, but Gaussian smoothing restored accuracy to scenario 1 levels. In scenario 3, joint estimation maintained <1% bias in nearly all regions. For real scans, the MC-based scatter estimate closely matched the vendor-provided scatter estimate. This proof-of-concept demonstrates that scatter sensitivity modeling can enhance simulators by incorporating detector physics. It supports the feasibility of using fast MC simulations for real scans, offering improved accuracy and robustness to acquisition noise in clinical PET reconstruction.

physics.med-ph↗

Improved energy-based scatter estimation by incorporating local energy spectra and accelerating the parametric fitting

PET requires accurate, precise, and efficient scatter correction techniques. Conventional scatter estimation typically relies on tail-fitted single-scatter simulation (SSS) strategy. However, the accuracy of tail-fitted SSS is limited, for example, by mismatches between the attenuation image and the PET emission data or by the presence of activity outside the FOV. These shortcomings can be addressed using energy-based scatter estimation (EBSE), as recently proposed by Efthimiou et al. and Hamill et al. The aim of this work is to 1. improve the accuracy of EBSE by accounting for the LOR dependence of the energy spectrum of unscattered photons, 2. improve the computational speed of EBSE through better initialization and a more efficient optimization algorithm. The proposed improved EBSE method models the energy probability density function (PDF) of both single and multiple scattered photons, and incorporates a position-dependent energy PDF for unscattered photons. These energy PDFs form the basis of two forward models used for scatter estimation based on 2D energy histograms. The performance of these models were evaluated using GATE Monte Carlo simulations and a NEMA phantom acquisition on a GE SIGNA PET/MR scanner. Furthermore, we assessed the stability of EBSE across the forward models by varying the number of counts in the 2D energy histograms via data mashing. EBSE outperformed tail-fitted SSS, particularly in regions near out-of-FOV activity. Our GATE simulations showed that incorporating a local energy for unscattered photons improves off-center regional quantification by approximately 2% points. Additionally, improved initialization combined with the NEGML optimizer enabling execution on a mashed TOF sinogram in 12 minutes on six-core CPU. The proposed method enhances both the accuracy and computational efficiency of EBSE, making it well-suited for clinical applications.

physics.med-ph↗