SearcharxivSearch

arXiv subjects

Shahram Shirani

Publications and source records attributed to Shahram Shirani.

At least 19 recordsLinked to original sources

Meta-Learning for Classifier Selection in Image Datasets: A Feature-Driven Framework for Accuracy Prediction

No Free Lunch theorem implies that any performance gains achieved by a classifier on a particular image distribution are necessarily offset by a loss of performance over the set of all possible problems; thus, no single model is universally optimal. Selecting the most suitable classifier for image datasets is a critical yet challenging task due to the intrinsic complexity and diversity of images. This paper proposes a meta-learning framework that leverages a comprehensive set of meta-features capturing dataset complexity to predict classifier performance without exhaustive training. By extracting and selecting features using methods such as autoencoders, pre-trained networks, and dimensionality reduction techniques, we train regression models to efficiently estimate classifier accuracies. Additionally, clustering techniques are employed to group classifiers with similar performance patterns, simplifying the recommendation process. The datasets used span a wide range of concepts, including nature, animals, numbers, motorcycles, medical images, and human bodies, to ensure broad generalization. Evaluated on 56 diverse image datasets, our approach achieves an average ranking prediction accuracy exceeding 86%, demonstrating its effectiveness in guiding model selection. This scalable and interpretable framework provides a practical solution to improve classification performance while reducing computational costs.

cs.CV

EvoGS: Modeling Deformation Evolution for Dynamic Gaussian Splatting

Recent extensions of 3D Gaussian Splatting (3DGS) enable real-time novel view synthesis in dynamic scenes by learning time-conditioned Gaussian deformations. However, existing MLP-based methods typically estimate deformations independently at each timestamp, making them less robust to large or abrupt motions. To address this issue, we propose \textbf{EvoGS}, a 3DGS-based dynamic reconstruction framework that models Gaussian deformation as a temporal evolution process. EvoGS maintains persistent deformation states for each Gaussian, extrapolates future states from historical deformation states, and corrects the predictions with MLP-derived observations. The correction is adaptively weighted using a temporal residual memory and evolution statistics such as deformation velocity and trajectory deviation. To further improve reconstruction quality, EvoGS introduces deformation-aware densification. Clone and split operations are performed along corrected deformation directions, while an uncertainty-aware strategy suppresses densification for Gaussians with unstable deformation histories. Experiments show that EvoGS improves dynamic novel view synthesis quality and achieves competitive performance across benchmarks.

cs.CV

XVAE-WMT: Explainable Wavelet-Temporal Variational Autoencoder for Blind Source Separation of Heart and Lung Sounds

The separation of cardiovascular sounds is a critical task in biomedical signal processing. In this paper, we introduce XVAE-WMT1, an unsupervised explainable generative AI algorithm combining a variational autoencoder (VAE) with explainable AI (XAI), wavelet-based inputs, a post-hoc output mask, and temporal consistency (TC) loss. Unlike existing supervised and VAE-based methods that rely on Short-Time Fourier Transform (STFT) and ignore latent interpretability, XVAE-WMT requires no paired clean recordings and integrates a Continuous Wavelet Transform (CWT) front-end for superior time-frequency localization. We assessed the latent space interpretability via different metrics, with SHAP (SHapley Additive exPlanations) enabling dimensionality reduction to the top 75% of latent features while preserving separation quality. Evaluated across two datasets using Signal-to-Distortion Ratio (SDR), Signal-to-Interference Ratio (SIR), and Signal-to-Artifacts Ratio (SAR), XVAE-WMT attains 26.8 dB SDR, 32.8 dB SIR, and 28.6 dB SAR.

cs.SD

RAVQ-HoloNet: Rate-Adaptive Vector-Quantized Hologram Compression

Holography offers significant potential for AR/VR applications. However, its adoption is limited by the high demand for data compression. Existing deep learning approaches generally lack rate adaptivity within a single network and often require multiple models to cover different bandwidth requirements. We present RAVQ-HoloNet, a rate-adaptive vector quantization framework that integrates the rate-adaptive compression with the transformation of image data into phase-only hologram. RAVQ-HoloNet achieves high-fidelity reconstructions, outperforming current state-of-the-art methods implemented via two distinct architectural configurations: a standard model optimized for low bit rates and a deeper, extended variant tailored for ultra low bit rate setting. To evaluate these models, we utilized the DIV2K dataset as a benchmark for high-fidelity holographic reconstruction. Quantitative analysis in the simulation reveals that our approach significantly surpasses current benchmarks. Specifically, in the low bit rate domain, our method achieves a BD-Rate reduction of -33.91% and a BD-PSNR gain of 1.02dB relative to the state-of-the-art method. Additionally, experimental results on the SLM device show that our method achieves higher contrast and improved quality.

cs.LG

HistoFusionNet: Histogram-Guided Fusion and Frequency-Adaptive Refinement for Nighttime Image Dehazing

Nighttime image dehazing remains a challenging low-level vision problem due to the joint presence of haze, glow, non-uniform illumination, color distortion, and sensor noise, which often invalidate assumptions commonly used in daytime dehazing. To address these challenges, we propose HistoFusionNet, a transformer-enhanced architecture tailored for nighttime image dehazing by combining histogram-guided representation learning with frequency-adaptive feature refinement. Built upon a multi-scale encoder-decoder backbone, our method introduces histogram transformer blocks that model long-range dependencies by grouping features according to their dynamic-range characteristics, enabling more effective aggregation of similarly degraded regions under complex nighttime lighting. To further improve restoration fidelity, we incorporate a frequency-aware refinement branch that adaptively exploits complementary low- and high-frequency cues, helping recover scene structures, suppress artifacts, and enhance local details. This design yields a unified framework that is particularly well suited to the heterogeneous degradations encountered in real nighttime hazy scenes. Extensive experiments and highly competitive performance of our method on the NTIRE 2026 Nighttime Image Dehazing Challenge benchmark demonstrate the effectiveness of the proposed method. Our team ranked 1st among 22 participating teams, highlighting the robustness and competitive performance of HistoFusionNet. The code is available at: https://github.com/heydarimo/Night-Time-Dehazing

cs.CV

QuPCG: Quantum Convolutional Neural Network for Detecting Abnormal Patterns in PCG Signals

Early identification of abnormal physiological patterns is essential for the timely detection of cardiac disease. This work introduces a hybrid quantum-classical convolutional neural network (QCNN) designed to classify S3 and murmur abnormalities in heart sound signals. The approach transforms one-dimensional phonocardiogram (PCG) signals into compact two-dimensional images through a combination of wavelet feature extraction and adaptive threshold compression methods. We compress the cardiac-sound patterns into an 8-pixel image so that only 8 qubits are needed for the quantum stage. Preliminary results on the HLS-CMDS dataset demonstrate 93.33% classification accuracy on the test set and 97.14% on the train set, suggesting that quantum models can efficiently capture temporal-spectral correlations in biomedical signals. To our knowledge, this is the first application of a QCNN algorithm for bioacoustic signal processing. The proposed method represents an early step toward quantum-enhanced diagnostic systems for resource-constrained healthcare environments.

cs.LG

Chem-NMF: Multi-layer $α$-divergence Non-Negative Matrix Factorization for Cardiorespiratory Disease Clustering, with Improved Convergence Inspired by Chemical Catalysts and Rigorous Asymptotic Analysis

Non-Negative Matrix Factorization (NMF) is an unsupervised learning method offering low-rank representations across various domains such as audio processing, biomedical signal analysis, and image recognition. The incorporation of $α$-divergence in NMF formulations enhances flexibility in optimization, yet extending these methods to multi-layer architectures presents challenges in ensuring convergence. To address this, we introduce a novel approach inspired by the Boltzmann probability of the energy barriers in chemical reactions to theoretically perform convergence analysis. We introduce a novel method, called Chem-NMF, with a bounding factor which stabilizes convergence. To our knowledge, this is the first study to apply a physical chemistry perspective to rigorously analyze the convergence behaviour of the NMF algorithm. We start from mathematically proven asymptotic convergence results and then show how they apply to real data. Experimental results demonstrate that the proposed algorithm improves clustering accuracy by 5.6% $\pm$ 2.7% on biomedical signals and 11.1% $\pm$ 7.2% on face images (mean $\pm$ std).

cs.LG

Quantum Biosensors on Chip: A Review from Electronic and Photonic Integrated Circuits to Future Integrated Quantum Photonic Circuits

Quantum biosensors offer a promising route to overcome the sensitivity and specificity limitations of conventional biosensing technologies. Their ability to detect biochemical signals at extremely low concentrations makes them strong candidates for next-generation sensing systems. This paper reviews the current state of quantum biosensors and dis-cusses their future implementation in chip-scale platforms that combine microelectronic and photonic technologies. It covers key quantum biosensing approaches including quantum dots, and nitrogen-vacancy (NV) centers. This paper also considers their po-tential compatibility with electronic integrated circuits (EICs), photonic integrated circuits (PICs) and integrated quantum photonic (IQP) systems for future biosensing applications. To our knowledge, this is the first review to systematically connect quantum biosensing technologies with the development of microelectronic and photonic chip-based devices. The goal is to clarify the technological trajectory toward compact, scalable, and high-performance quantum biosensing systems.

physics.optics

High-Quality Live Video Streaming via Transcoding Time Prediction and Preset Selection

Video streaming often requires transcoding content into different resolutions and bitrates to match the recipient's internet speed and screen capabilities. Video encoders like x264 offer various presets, each with different tradeoffs between transcoding time and rate-distortion performance. Choosing the best preset for video transcoding is difficult, especially for live streaming, as trying all the presets and choosing the best one is not feasible. One solution is to predict each preset's transcoding time and select the preset that ensures the highest quality while adhering to live streaming time constraints. Prediction of video transcoding time is also critical in minimizing streaming delays, deploying resource management algorithms, and load balancing. We propose a learning-based framework for predicting the transcoding time of videos across various presets. Our predictor's features for video transcoding time prediction are derived directly from the ingested stream, primarily from the header or metadata. As a result, only minimal additional delay is incurred for feature extraction, rendering our approach ideal for live-streaming applications. We evaluated our learning-based transcoding time prediction using a dataset of videos. The results demonstrate that our framework can accurately predict the transcoding time for different presets, with a mean absolute percentage error (MAPE) of nearly 5.0%. Leveraging these predictions, we then select the most suitable transcoding preset for live video streaming. Utilizing our transcoding time prediction-based preset selection improved Peak Signal-to-Noise Ratio (PSNR) of up to 5 dB.

cs.MM

Large Language Models and Non-Negative Matrix Factorization for Bioacoustic Signal Decomposition

Large language models have shown a remarkable ability to extract meaning from unstructured data, offering new ways to interpret biomedical signals beyond traditional numerical methods. In this study, we present a matrix factorization framework for bioacoustic signal analysis which is enhanced by large language models. The focus is on separating bioacoustic signals that commonly overlap in clinical recordings, using matrix factorization to decompose the mixture into interpretable components. A large language model is then applied to the separated signals to associate distinct acoustic patterns with potential medical conditions such as cardiac rhythm disturbances or respiratory abnormalities. Recordings were obtained from a digital stethoscope applied to a clinical manikin to ensure a controlled and high-fidelity acquisition environment. This hybrid approach does not require labeled data or prior knowledge of source types, and it provides a more interpretable and accessible framework for clinical decision support. The method demonstrates promise for integration into future intelligent diagnostic tools.

eess.AS

Blind Source Separation in Biomedical Signals Using Variational Methods

This study introduces a novel unsupervised approach for separating overlapping heart and lung sounds using variational autoencoders (VAEs). In clinical settings, these sounds often interfere with each other, making manual separation difficult and error-prone. The proposed model learns to encode mixed signals into a structured latent space and reconstructs the individual components using a probabilistic decoder, all without requiring labeled data or prior knowledge of source characteristics. We apply this method to real recordings obtained from a clinical manikin using a digital stethoscope. Results demonstrate distinct latent clusters corresponding to heart and lung sources, as well as accurate reconstructions that preserve key spectral features of the original signals. The approach offers a robust and interpretable solution for blind source separation and has potential applications in portable diagnostic tools and intelligent stethoscope systems.

eess.AS

A New Non-Negative Matrix Factorization Approach for Blind Source Separation of Cardiovascular and Respiratory Sound Based on the Periodicity of Heart and Lung Function

Auscultation provides a rich diversity of information to diagnose cardiovascular and respiratory diseases. However, sound auscultation is challenging due to noise. In this study, a modified version of the affine non-negative matrix factorization (NMF) approach is proposed to blindly separate lung and heart sounds recorded by a digital stethoscope. This method applies a novel NMF algorithm, which embodies a parallel structure of multilayer units on the input signal, to find a proper estimation of source signals. Another key innovation is the use of the periodic property of the signals which improves accuracy compared to previous works. The method is tested on 100 cases. Each case consists of two synthesized mixtures of real measurements. The effect of different parameters is discussed, and the results are compared to other current methods. Results demonstrate improvements in the source-to-distortion ratio (SDR), source-to-interference ratio (SIR), and source-to-artifacts ratio (SAR) of heart and lung sounds, respectively.

eess.SP

MEMS and ECM Sensor Technologies for Cardiorespiratory Sound Monitoring - A Comprehensive Review

This paper presents a comprehensive review of cardiorespiratory auscultation sensing devices (i.e., stethoscopes), which is useful for understanding the theoretical aspects and practical design notes. In this paper, we first introduce the acoustic properties of the heart and lungs, as well as a brief history of stethoscope evolution. Then, we discuss the basic concept of electret condenser microphones (ECMs) and a stethoscope based on them. Then, we discuss the microelectromechanical systems (MEMSs) technology, particularly focusing on piezoelectric transducer sensors. This paper comprehensively reviews sensing technologies for cardiorespiratory auscultation, emphasizing MEMS-based wearable designs in the past decade. To our knowledge, this is the first paper to summarize ECM and MEMS applications for heart and lung sound analysis.

eess.SP

Large Language Model-based Nonnegative Matrix Factorization For Cardiorespiratory Sound Separation

This study represents the first integration of large language models (LLMs) with non-negative matrix factorization (NMF), marking a novel advancement in the source separation field. The LLM is employed in two unique ways: enhancing the separation results by providing detailed insights for disease prediction and operating in a feedback loop to optimize a fundamental frequency penalty added to the NMF cost function. We tested the algorithm on two datasets: 100 synthesized mixtures of real measurements, and 210 recordings of heart and lung sounds from a clinical manikin including both individual and mixed sounds, captured using a digital stethoscope. The approach consistently outperformed existing methods, demonstrating its potential to significantly enhance medical sound analysis for disease diagnostics.

cs.SD

BrightVAE: Luminosity Enhancement in Underexposed Endoscopic Images

The enhancement of image luminosity is especially critical in endoscopic images. Underexposed endoscopic images often suffer from reduced contrast and uneven brightness, significantly impacting diagnostic accuracy and treatment planning. Internal body imaging is challenging due to uneven lighting and shadowy regions. Enhancing such images is essential since precise image interpretation is crucial for patient outcomes. In this paper, we introduce BrightVAE, an architecture based on the hierarchical Vector Quantized Variational Autoencoder (hierarchical VQ-VAE) tailored explicitly for enhancing luminosity in low-light endoscopic images. Our architecture is meticulously designed to tackle the unique challenges inherent in endoscopic imaging, such as significant variations in illumination and obscured details due to poor lighting conditions. The proposed model emphasizes advanced feature extraction from three distinct viewpoints-incorporating various receptive fields, skip connections, and feature attentions to robustly enhance image quality and support more accurate medical diagnoses. Through rigorous experimental analysis, we demonstrate the effectiveness of these techniques in enhancing low-light endoscopic images. To evaluate the performance of our architecture, we employ three widely recognized metrics-SSIM, PSNR, and LPIPS-specifically on Endo4IE dataset, which consists of endoscopic images. We evaluated our method using the Endo4IE dataset, which consists exclusively of endoscopic images, and showed significant advancements over the state-of-the-art methods for enhancing luminosity in endoscopic imaging.

eess.IV

Optimal Transcoding Preset Selection for Live Video Streaming

In today's digital landscape, video content dominates internet traffic, underscoring the need for efficient video processing to support seamless live streaming experiences on platforms like YouTube Live, Twitch, and Facebook Live. This paper introduces a comprehensive framework designed to optimize video transcoding parameters, with a specific focus on preset and bitrate selection to minimize distortion while respecting constraints on bitrate and transcoding time. The framework comprises three main steps: feature extraction, prediction, and optimization. It leverages extracted features to predict transcoding time and rate-distortion, employing both supervised and unsupervised methods. By utilizing integer linear programming, it identifies the optimal sequence of presets and bitrates for video segments, ensuring real-time application feasibility under set constraints. The results demonstrate the framework's effectiveness in enhancing video quality for live streaming, maintaining high standards of video delivery while managing computational resources efficiently. This optimization approach meets the evolving demands of video delivery by offering a solution for real-time transcoding optimization. Evaluation using the User Generated Content dataset showed an average PSNR improvement of 1.5 dB over the default Twitch configuration, highlighting significant PSNR gains. Additionally, subsequent experiments demonstrated a BD-rate reduction of -49.60%, reinforcing the framework's superior performance over Twitch's default configuration.

cs.MM

Manikin-Recorded Cardiopulmonary Sounds Dataset Using Digital Stethoscope

Heart and lung sounds are crucial for healthcare monitoring. Recent improvements in stethoscope technology have made it possible to capture patient sounds with enhanced precision. In this dataset, we used a digital stethoscope to capture both heart and lung sounds, including individual and mixed recordings. To our knowledge, this is the first dataset to offer both separate and mixed cardiorespiratory sounds. The recordings were collected from a clinical manikin, a patient simulator designed to replicate human physiological conditions, generating clean heart and lung sounds at different body locations. This dataset includes both normal sounds and various abnormalities (i.e., murmur, atrial fibrillation, tachycardia, atrioventricular block, third and fourth heart sound, wheezing, crackles, rhonchi, pleural rub, and gurgling sounds). The dataset includes audio recordings of chest examinations performed at different anatomical locations, as determined by specialist nurses. Each recording has been enhanced using frequency filters to highlight specific sound types. This dataset is useful for applications in artificial intelligence, such as automated cardiopulmonary disease detection, sound classification, unsupervised separation techniques, and deep learning algorithms related to audio signal processing.

eess.AS

Sequence-to-Sequence Multi-Modal Speech In-Painting

Speech in-painting is the task of regenerating missing audio contents using reliable context information. Despite various recent studies in multi-modal perception of audio in-painting, there is still a need for an effective infusion of visual and auditory information in speech in-painting. In this paper, we introduce a novel sequence-to-sequence model that leverages the visual information to in-paint audio signals via an encoder-decoder architecture. The encoder plays the role of a lip-reader for facial recordings and the decoder takes both encoder outputs as well as the distorted audio spectrograms to restore the original speech. Our model outperforms an audio-only speech in-painting model and has comparable results with a recent multi-modal speech in-painter in terms of speech quality and intelligibility metrics for distortions of 300 ms to 1500 ms duration, which proves the effectiveness of the introduced multi-modality in speech in-painting.

cs.SD