SearcharxivSearch

arXiv subjects

Shahriar Ahmed

Publications and source records attributed to Shahriar Ahmed.

2 recordsLinked to original sources

Synthetic and Derived Training Images for Campus Waste Detection: A Multi-Seed Evaluation with YOLOv8n

Incorrect disposal can contaminate campus recycling streams, and a bin-mounted camera could provide feedback as an item is discarded. We evaluated whether synthetic and derived images improve a YOLOv8n detector for this view. The real dataset contained 148 campus photographs: 86 for training, 31 for validation, and 31 for testing. Twelve joint-training configurations varied the amount and source of added images. We repeated seven principal settings with four matched seeds and computed bootstrap percentile intervals over those seeds. The real-only model reached a mean mAP@0.5 of 0.691 [0.665, 0.722]. Background replacement reduced the mean to 0.560 [0.499, 0.619], isolated-object images gave 0.680 [0.644, 0.724], and the full augmentation pool gave 0.487 [0.438, 0.537]. We also tested hand-and-forearm composites because every real photo showed a held object. Two cutouts in the initial composite set came from test photographs, so we discarded that experiment, rebuilt the set with training-split cutouts, and reran all four seeds. The corrected paired difference was +0.034 [-0.063, 0.199], which does not support a reliable hand-composite effect. Single-seed transfer experiments produced source-dependent rankings between joint mixing and sequential pretraining. None of the evaluated configurations exceeded the real-only baseline. The reported intervals quantify seed variation; the 31-photo test set remains too small for strong class-specific conclusions.

cs.CV

Can artificial intelligence (AI) be used to accurately detect tuberculosis (TB) from chest X-rays? An evaluation of five AI products for TB screening and triaging in a high TB burden setting

Artificial intelligence (AI) products can be trained to recognize tuberculosis (TB)-related abnormalities on chest radiographs. Various AI products are available commercially, yet there is lack of evidence on how their performance compared with each other and with radiologists. We evaluated five AI software products for screening and triaging TB using a large dataset that had not been used to train any commercial AI products. Individuals (>=15 years old) presenting to three TB screening centers in Dhaka, Bangladesh, were recruited consecutively. All CXR were read independently by a group of three Bangladeshi registered radiologists and five commercial AI products: CAD4TB (v7), InferReadDR (v2), Lunit INSIGHT CXR (v4.9.0), JF CXR-1 (v2), and qXR (v3). All five AI products significantly outperformed the Bangladeshi radiologists. The areas under the receiver operating characteristic curve are qXR: 90.81% (95% CI:90.33-91.29%), CAD4TB: 90.34% (95% CI:89.81-90.87), Lunit INSIGHT CXR: 88.61% (95% CI:88.03%-89.20%), InferReadDR: 84.90% (95% CI: 84.27-85.54%) and JF CXR-1: 84.89% (95% CI:84.26-85.53%). Only qXR met the TPP with 74.3% specificity at 90% sensitivity. Five AI algorithms can reduce the number of Xpert tests required by 50%, while maintaining a sensitivity above 90%. All AI algorithms performed worse among the older age and people with prior TB history. AI products can be highly accurate and useful screening and triage tools for TB detection in high burden regions and outperform human readers.

eess.IV