SearcharxivSearch

arXiv subjects

Shaorui Li

Publications and source records attributed to Shaorui Li.

11 recordsLinked to original sources

Skipper-in-CMOS: Non-Destructive Readout with Sub-Electron Noise Performance for Pixel Detectors

The Skipper-in-CMOS image sensor integrates the non-destructive readout capability of Skipper Charge Coupled Devices (Skipper-CCDs) with the high conversion gain of a pinned photodiode in a CMOS imaging process, while taking advantage of in-pixel signal processing. This allows both single photon counting as well as high frame rate readout through highly parallel processing. The first results obtained from a 15 x 15 um^2 pixel cell of a Skipper-in-CMOS sensor fabricated in Tower Semiconductor's commercial 180 nm CMOS Image Sensor process are presented. Measurements confirm the expected reduction of the readout noise with the number of samples down to deep sub-electron noise of 0.15rms e-, demonstrating the charge transfer operation from the pinned photodiode and the single photon counting operation when the sensor is exposed to light. The article also discusses new testing strategies employed for its operation and characterization.

astro-ph.IM

Gate-controlled neuromorphic functional transition in an electrochemical graphene transistor

Neuromorphic devices have gained significant attention as potential building blocks for the next generation of computing technologies owing to their ability to emulate the functionalities of biological nervous systems. The essential components in artificial neural network such as synapses and neurons are predominantly implemented by dedicated devices with specific functionalities. In this work, we present a gate-controlled transition of neuromorphic functions between artificial neurons and synapses in monolayer graphene transistors that can be employed as memtransistors or synaptic transistors as required. By harnessing the reliability of reversible electrochemical reactions between C atoms and hydrogen ions, the electric conductivity of graphene transistors can be effectively manipulated, resulting in high on/off resistance ratio, well-defined set/reset voltage, and prolonged retention time. Overall, the on-demand switching of neuromorphic functions in a single graphene transistor provides a promising opportunity to develop adaptive neural networks for the upcoming era of artificial intelligence and machine learning.

physics.app-ph

A Sub-Electron-Noise Multi-Channel Cryogenic Skipper-CCD Readout ASIC

The \emph{MIDNA} application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that process the skipper-CCD signal and performs differential averaging using a dual slope integration (DSI) circuit. Each readout channel contains a pre-amplifier, a DC restorer, and a dual-slope integrator with chopping capability. The integrator chopping is a key system design element in order to mitigate the effect of low-frequency noise produced by the integrator itself, and it is not often required with standard CCDs. Each channel consumes 4.5 mW of power, occupies 0.156 mm${^2}$ area and has an input referred noise of 2.7${\mu\nu}_{rms}$. It is demonstrated experimentally to achieve sub-electron noise when coupled with a skipper-CCD by means of averaging samples of each pixel. Sub-electron noise is shown in three different acquisition approaches. The signal range is 6000 electrons. The readout system achieves 0.2${e^{-}}$ RMS by averaging 1000 samples with MIDNA both at room temperature and at 180 Kelvin.

physics.app-ph

Performance of the X-Calibur Hard X-Ray Polarimetry Mission during its 2018/19 Long-Duration Balloon Flight

X-Calibur is a balloon-borne telescope that measures the polarization of high-energy X-rays in the 15--50keV energy range. The instrument makes use of the fact that X-rays scatter preferentially perpendicular to the polarization direction. A beryllium scattering element surrounded by pixellated CZT detectors is located at the focal point of the InFOC{\mu}S hard X-ray mirror. The instrument was launched for a long-duration balloon (LDB) flight from McMurdo (Antarctica) on December 29, 2018, and obtained the first constraints of the hard X-ray polarization of an accretion-powered pulsar. Here, we describe the characterization and calibration of the instrument on the ground and its performance during the flight, as well as simulations of particle backgrounds and a comparison to measured rates. The pointing system and polarimeter achieved the excellent projected performance. The energy detection threshold for the anticoincidence system was found to be higher than expected and it exhibited unanticipated dead time. Both issues will be remedied for future flights. Overall, the mission performance was nominal, and results will inform the design of the follow-up mission XL-Calibur, which is scheduled to be launched in summer 2022.

astro-ph.IM

Programs Enabling Deep Technology Transfer from National Labs

To maximize the technology transfer potential, it is important to create an ecosystem for the inventors to adapt the technologies developed for basic science to successful commercial ventures. In this white paper we present a brief overview of technology transfer programs at high energy physics (HEP) laboratories with a focus on the programs at Fermilab and KEK, and identify opportunities and recommendations for increasing partnerships and commercialization at HEP-centric laboratories.

physics.soc-ph

Big Industry Engagement to Benefit HEP: Microelectronics Support from Large CAD Companies

Microelectronics development is critical to a wide number of DOE projects and mission space. Creating Helpful Incentives to Produce Semiconductors (CHIPS) and manufacturing Application Specific Integrated Circuits (ASIC) are important to DOE, so the infrastructure that allows DOE to carry out its mission needs to exist. This paper discusses the current initiatives and recommends a business model to build an ecosystem for microelectronics design for DOE which includes three main building blocks: the Computer Aided Design (CAD) - Electronic Design Automation (EDA) design tools, basic design IPs, and access to semiconductor fabrication facilities.

physics.soc-ph

Distinct quantum anomalous Hall ground states induced by magnetic disorders

The quantum anomalous Hall (QAH) effect in magnetic topological insulator (TI) represents a new state of matter originated from the interplay between topology and magnetism. The defining characteristics of the QAH ground state are the quantized Hall resistivity ($ρ_{yx}$) and vanishing longitudinal resistivity ($ρ_{xx}$) in the absence of external magnetic field. A fundamental question concerning the QAH effect is whether it is merely a zero-magnetic-field quantum Hall (QH) effect, or if it can host unique quantum phases and phase transitions that are unavailable elsewhere. The most dramatic departure of the QAH systems from other QH systems lies in the strong magnetic disorders that induce spatially random magnetization. Because disorder and magnetism play pivotal roles in the phase diagram of two-dimensional electron systems, the high degree of magnetic disorders in QAH systems may create novel phases and quantum critical phenomena. In this work, we perform systematic transport studies of a series of magnetic TIs with varied strength of magnetic disorders. We find that the ground state of QAH effect can be categorized into two distinct classes: the QAH insulator and anomalous Hall (AH) insulator phases, as the zero-magnetic-field counterparts of the QH liquid and Hall insulator in the QH systems. In the low disorder limit of the QAH insulator regime, we observe a universal quantized longitudinal resistance $ρ_{xx} = h/e^{2}$ at the coercive field. In the AH insulator regime, we find that a magnetic field can drive it to the QAH insulator phase through a quantum critical point with distinct scaling behaviors from that in the QH phase transition. We propose that the transmission between chiral edge states at domain boundaries, tunable by disorder and magnetic fields, is the key for determining the QAH ground state.

cond-mat.mes-hall

Large Transport Gap Modulation in Graphene via Electric Field Controlled Reversible Hydrogenation

Graphene is of interest in the development of next-generation electronics due to its high electron mobility, flexibility and stability. However, graphene transistors have poor on/off current ratios because of the absence of a bandgap. One approach to introduce an energy gap is to use hydrogenation reaction, which changes graphene into insulating graphane with sp3 bonding. Here we show that an electric field can be used to control conductor-to-insulator transitions in microscale graphene via a reversible electrochemical hydrogenation in an organic liquid electrolyte containing dissociative hydrogen ions. The fully hydrogenated graphene exhibits a lower limit sheet resistance of 200 Gohm/sq, resulting in graphene field-effect transistors with on/off current ratios of 10^8 at room temperature. The devices also exhibit high endurance, with up to one million switching cycles. Similar insulating behaviours are also observed in bilayer graphene, while trilayer graphene remains highly conductive after the hydrogenation. Changes in the graphene lattice, and the transformation from sp2 to sp3 hybridization, is confirmed by in-situ Raman spectroscopy, supported by first-principles calculations.

cond-mat.mtrl-sci

Quantum anomalous Hall multilayers grown by molecular beam epitaxy

Quantum anomalous Hall (QAH) effect is a quantum Hall effect that occurs without the need of external magnetic field. A system composed of multiple parallel QAH layers is an effective high Chern number QAH insulator and the key to the applications of the dissipationless chiral edge channels in low energy consumption electronics. Such a QAH multilayer can also be engineered into other exotic topological phases such as a magnetic Weyl semimetal with only one pair of Weyl points. This work reports the first experimental realization of QAH multilayers in the superlattices composed of magnetically doped (Bi,Sb)$_2$Te$_3$ topological insulator and CdSe normal insulator layers grown by molecular beam epitaxy. The obtained multilayer samples show quantized Hall resistance $h/Ne$$^2$, where $h$ is the Planck's constant, $e$ is the elementary charge and $N$ is the number of the magnetic topological insulator layers, resembling a high Chern number QAH insulator.

cond-mat.mtrl-sci

Design of the telescope truss and gondola for the balloon-borne X-ray polarimeter X-Calibur

X-ray polarimetry has seen a growing interest in recent years. Improvements in detector technology and focusing X-ray optics now enable sensitive astrophysical X-ray polarization measurements. These measurements will provide new insights into the processes at work in accreting black holes, the emission of X-rays from neutron stars and magnetars, and the structure of AGN jets. X-Calibur is a balloon-borne hard X-ray scattering polarimeter. An X-ray mirror with a focal length of 8 m focuses X-rays onto the detector, which consists of a plastic scattering element surrounded by Cadmium-Zinc-Telluride detectors, which absorb and record the scattered X-rays. Since X-rays preferentially scatter perpendicular to their polarization direction, the polarization properties of an X-ray beam can be inferred from the azimuthal distribution of scattered X-rays. A close alignment of the X-ray focal spot with the center of the detector is required in order to reduce systematic uncertainties and to maintain a high photon detection efficiency. This places stringent requirements on the mechanical and thermal stability of the telescope structure. During the flight on a stratospheric balloon, X-Calibur makes use of the Wallops Arc-Second Pointer (WASP) to point the telescope at astrophysical sources. In this paper, we describe the design, construction, and test of the telescope structure, as well as its performance during a 25-hour flight from Ft. Sumner, New Mexico. The carbon fiber-aluminum composite structure met the requirements set by X-Calibur and its design can easily be adapted for other types of experiments, such as X-ray imaging or spectroscopic telescopes.

astro-ph.IM

Optimization of <= 200 um pitch CZT detectors for future high-resolution X-ray instrumentation in astrophysics

Cadmium Zinc Telluride and Cadmium Telluride are the detector materials of choice for the detection of X-rays in the X-ray energy band E >= 5keV with excellent spatial and spectral resolution and without cryogenic cooling. Owing to recent breakthroughs in grazing incidence mirror technology, next-generation hard X-ray telescopes will achieve angular resolution between 5 and 10 arc seconds - about an order of magnitude better than that of the NuSTAR hard X-ray telescope. As a consequence, the next generation of X-ray telescopes will require pixelated X-ray detectors with pixels on a grid with a lattice constant of <= 250um. Additional detector requirements include a low energy threshold of less than 5keV and an energy resolution of less than one keV. The science drivers for a high angular-resolution X-ray mission include studies and measurements of black hole spins, the cosmic evolution of super-massive black holes, active galactic nuclei feedback, and the behaviour of matter at very high densities. In this contribution, we report on our R&D studies with the goal to optimise small-pixel Cadmium Zinc Telluride and Cadmium Telluride detectors.

physics.ins-det