SearcharxivSearch

arXiv subjects

Shaoyang Dai

Publications and source records attributed to Shaoyang Dai.

3 recordsLinked to original sources

Realization of the SI Second Defined by Geometric Mean of Multiple Clock Transitions

The current definition of the SI second is based on the 133Cs ground-state hyperfine transition in the microwave domain, with the most accurate realizations achieving fractional frequency uncertainties of about (1-2)E16. In contrast, state-of-the-art optical clocks now demonstrate estimated uncertainties two to three orders of magnitude lower, prompting discussion on the redefinition of the SI second. Several options for the new definition have been proposed, one of which introduces a constant N defined as the weighted geometric mean of multiple clock transition frequencies. In this work, we investigate how N can be practically realized when not all defining transitions are available and when multiple optical clocks operate with different performance levels and non-overlapping uptimes. We consider two complementary realization and reconstruction routes. One route is based on geometric-mean combinations, and the other is based on arithmetic-mean combinations. We derive consistent uncertainty expressions that incorporate both measurement uncertainties and, where required, uncertainties of recommended frequencies or frequency ratios. Using analytic three-transition case studies, we identify the parameter regimes in which each route yields a lower total uncertainty and provide explicit conditions for the crossover between them. We further address the dominant role of dead time when a hydrogen maser serves as a flywheel reference by introducing a time-segmented, time-weighted combination based on coefficient and covariance matrices, which accounts for overlapping operation and correlations across measurement intervals. Our findings offer practical guidance for minimizing total uncertainty in multi-clock realizations and contribute to ongoing efforts toward redefining the SI second.

physics.atom-ph

Uncertainty Evaluation of the Caesium Fountain Primary Frequency Standard NIM6

A new caesium (Cs) fountain clock NIM6 has been developed at the National Institute of Metrology (NIM) in China, for which a comprehensive uncertainty evaluation is presented. A three-dimensional magneto-optical trap (3D MOT) loading optical molasses is employed to obtain more cold atoms rapidly and efficiently with a tunable, uniform density distribution. A heat pipe surrounding the flight tube maintains a consistent and stable temperature within the interrogation region. Additionally, a Ramsey cavity with four azimuthally distribution feeds is utilized to mitigate distributed cavity phase shifts. The Cs fountain clock NIM6 achieves a short-term stability of 1.0x10-13 τ-1/2 at high atomic density, and a typical overall fractional type-B uncertainty is estimated to be 2.3x10-16. Comparisons of frequency between the Cs fountain NIM6 and other Cs fountain Primary Frequency Standards (PFSs) through Coordinated Universal Time (UTC) have demonstrated an agreement within the stated uncertainties.

quant-ph

Development and Evaluation of a Narrow Linewidth Laser System for 171Yb+ E2 Transition

We report the construction and characterization of a narrow-linewidth laser system to interrogate the E2 clock transitions at 436 nm of ytterbium ions trapped in end-cap traps. The 871 nm seed laser at the fundamental frequency is referenced to a 10 cm long notched ULE cavity. The output of the laser system is delivered to a narrow-linewidth femtosecond fiber comb, which has been referenced to an ultrastable 698 nm laser, with a phase noise-canceled fiber link. The beat between the laser and the comb shows a sub-Hz linewidth, and with a stability better than 2E-15@1~100 s. The performance of the self-developed wavelength extension ports at 871 nm of the narrow linewidth erbium-doped fiber comb with single-point frequency-doubling technique is also verified.

physics.atom-ph