Searcharxiv⌕ Search

arXiv subjects

Shelley A. Wright

Publications and source records attributed to Shelley A. Wright.

At least 55 records · Page 3Linked to original sources

Following Black Hole Scaling Relations Through Gas-Rich Mergers

We present black hole mass measurements from kinematic modeling of high-spatial resolution integral field spectroscopy of the inner regions of 9 nearby (ultra-)luminous infrared galaxies in a variety of merger stages. These observations were taken with OSIRIS and laser guide star adaptive optics on the Keck I and Keck II telescopes, and reveal gas and stellar kinematics inside the spheres of influence of these supermassive black holes. We find that this sample of black holes are overmassive ($\sim10^{7-9}$ M$_{Sun}$) compared to the expected values based on black hole scaling relations, and suggest that the major epoch of black hole growth occurs in early stages of a merger, as opposed to during a final episode of quasar-mode feedback. The black hole masses presented are the dynamical masses enclosed in $\sim$25pc, and could include gas which is gravitationally bound to the black hole but has not yet lost sufficient angular momentum to be accreted. If present, this gas could in principle eventually fuel AGN feedback or be itself blown out from the system.

astro-ph.GA↗

The Infrared Imaging Spectrograph (IRIS) for TMT: Instrument Overview

We present an overview of the design of IRIS, an infrared (0.84 - 2.4 micron) integral field spectrograph and imaging camera for the Thirty Meter Telescope (TMT). With extremely low wavefront error (<30 nm) and on-board wavefront sensors, IRIS will take advantage of the high angular resolution of the narrow field infrared adaptive optics system (NFIRAOS) to dissect the sky at the diffraction limit of the 30-meter aperture. With a primary spectral resolution of 4000 and spatial sampling starting at 4 milliarcseconds, the instrument will create an unparalleled ability to explore high redshift galaxies, the Galactic center, star forming regions and virtually any astrophysical object. This paper summarizes the entire design and basic capabilities. Among the design innovations is the combination of lenslet and slicer integral field units, new 4Kx4k detectors, extremely precise atmospheric dispersion correction, infrared wavefront sensors, and a very large vacuum cryogenic system.

astro-ph.IM↗

The InfraRed Imaging Spectrograph (IRIS) for TMT: Overview of innovative science programs

IRIS (InfraRed Imaging Spectrograph) is a first light near-infrared diffraction limited imager and integral field spectrograph being designed for the future Thirty Meter Telescope (TMT). IRIS is optimized to perform astronomical studies across a significant fraction of cosmic time, from our Solar System to distant newly formed galaxies (Barton et al. [1]). We present a selection of the innovative science cases that are unique to IRIS in the era of upcoming space and ground-based telescopes. We focus on integral field spectroscopy of directly imaged exoplanet atmospheres, probing fundamental physics in the Galactic Center, measuring 10^4 to 10^10 Msun supermassive black hole masses, resolved spectroscopy of young star-forming galaxies (1 < z < 5) and first light galaxies (6 < z < 12), and resolved spectroscopy of strong gravitational lensed sources to measure dark matter substructure. For each of these science cases we use the IRIS simulator (Wright et al. [2], Do et al. [3]) to explore IRIS capabilities. To highlight the unique IRIS capabilities, we also update the point and resolved source sensitivities for the integral field spectrograph (IFS) in all five broadband filters (Z, Y, J, H, K) for the finest spatial scale of 0.004" per spaxel. We briefly discuss future development plans for the data reduction pipeline and quicklook software for the IRIS instrument suite.

astro-ph.IM↗

The Infrared Imaging Spectrograph (IRIS) for TMT: Volume phase holographic grating performance testing and discussion

Maximizing the grating efficiency is a key goal for the first light instrument IRIS (Infrared Imaging Spectrograph) currently being designed to sample the diffraction limit of the TMT (Thirty Meter Telescope). Volume Phase Holographic (VPH) gratings have been shown to offer extremely high efficiencies that approach 100% for high line frequencies (i.e., 600 to 6000l/mm), which has been applicable for astronomical optical spectrographs. However, VPH gratings have been less exploited in the near-infrared, particularly for gratings that have lower line frequencies. Given their potential to offer high throughputs and low scattered light, VPH gratings are being explored for IRIS as a potential dispersing element in the spectrograph. Our team has procured near-infrared gratings from two separate vendors. We have two gratings with the specifications needed for IRIS current design: 1.51-1.82μm (H-band) to produce a spectral resolution of 4000 and 1.19- 1.37 μm (J-band) to produce a spectral resolution of 8000. The center wavelengths for each grating are 1.629μm and 1.27μm, and the groove densities are 177l/mm and 440l/mm for H-band R=4000 and J-band R=8000, respectively. We directly measure the efficiencies in the lab and find that the peak efficiencies of these two types of gratings are quite good with a peak efficiency of ~88% at the Bragg angle in both TM and TE modes at H-band, and 90.23% in TM mode, 79.91% in TE mode at J-band for the best vendor. We determine the drop in efficiency off the Bragg angle, with a 20-23% decrease in efficiency at H-band when 2.5 degree deviation from the Bragg angle, and 25%-28% decrease at J-band when 5° deviation from the Bragg angle.

astro-ph.IM↗

The InfraRed Imaging Spectrograph (IRIS) for TMT: Reflective ruled diffraction grating performance testing and discussion

We present the efficiency of near-infrared reflective ruled diffraction gratings designed for the InfraRed Imaging Spectrograph (IRIS). IRIS is a first light, integral field spectrograph and imager for the Thirty Meter Telescope (TMT) and narrow field infrared adaptive optics system (NFIRAOS). We present our experimental setup and analysis of the efficiency of selected reflective diffraction gratings. These measurements are used as a comparison sample against selected candidate Volume Phase Holographic (VPH) gratings (see Chen et al., this conference). We investigate the efficiencies of five ruled gratings designed for IRIS from two separate vendors. Three of the gratings accept a bandpass of 1.19-1.37 μm (J band) with ideal spectral resolutions of R=4000 and R=8000, groove densities of 249 and 516 lines/mm, and blaze angles of 9.86 and 20.54 degrees, respectively. The other two gratings accept a bandpass of 1.51-1.82 μm (H Band) with an ideal spectral resolution of R=4000, groove density of 141 lines/mm, and blaze angle of 9.86°. We measure the efficiencies off blaze angle for all gratings and the efficiencies between the polarization transverse magnetic (TM) and transverse electric (TE) states. The peak reflective efficiencies are 98.90 +/- 3.36% (TM) and 84.99 +/- 2.74% (TM) for the H-band R=4000 and J-band R=4000 respectively. The peak reflective efficiency for the J-band R=8000 grating is 78.78 +/- 2.54% (TE). We find that these ruled gratings do not exhibit a wide dependency on incident angle within +/-3°. Our best-manufactured gratings were found to exhibit a dependency on the polarization state of the incident beam with a ~10-20% deviation, consistent with the theoretical efficiency predictions.

astro-ph.IM↗

A near-infrared SETI experiment: instrument overview

We are designing and constructing a new SETI (Search for Extraterrestrial Intelligence) instrument to search for direct evidence of interstellar communications via pulsed laser signals at near-infrared wavelengths. The new instrument design builds upon our past optical SETI experiences, and is the first step toward a new, more versatile and sophisticated generation of very fast optical and near-infrared pulse search devices. We present our instrumental design by giving an overview of the opto-mechanical design, detector selection and characterization, signal processing, and integration procedure. This project makes use of near-infrared (950-1650 nm) discrete amplification Avalanche Photodiodes (APD) that have greater than 1 GHz bandwidths with low noise characteristics and moderate gain (~10^4). We have investigated the use of single versus multiple detectors in our instrument (see Maire et al., this conference), and have optimized the system to have both high sensitivity and low false coincidence rates. Our design is optimized for use behind a 1m telescope and includes an optical camera for acquisition and guiding. A goal is to make our instrument relatively economical and easy to duplicate. We describe our observational setup and our initial search strategies for SETI targets, and for potential interesting compact astrophysical objects.

astro-ph.IM↗

A near-infrared SETI experiment: probability distribution of false coincidences

A Search for Extraterrestrial Life (SETI), based on the possibility of interstellar communication via laser signals, is being designed to extend the search into the near-infrared spectral region (Wright et al, this conference). The dedicated near-infrared (900 to 1700 nm) instrument takes advantage of a new generation of avalanche photodiodes (APD), based on internal discrete amplification. These discrete APD (DAPD) detectors have a high speed response ($>$ 1 GHz) and gain comparable to photomultiplier tubes, while also achieving significantly lower noise than previous APDs. We are investigating the use of DAPD detectors in this new astronomical instrument for a SETI search and transient source observations. We investigated experimentally the advantages of using a multiple detector device operating in parallel to remove spurious signals. We present the detector characterization and performance of the instrument in terms of false positive detection rates both theoretically and empirically through lab measurements. We discuss the required criteria that will be needed for laser light pulse detection in our experiment. These criteria are defined to optimize the trade between high detection efficiency and low false positive coincident signals, which can be produced by detector dark noise, background light, cosmic rays, and astronomical sources. We investigate experimentally how false coincidence rates depend on the number of detectors in parallel, and on the signal pulse height and width. We also look into the corresponding threshold to each of the signals to optimize the sensitivity while also reducing the false coincidence rates. Lastly, we discuss the analytical solution used to predict the probability of laser pulse detection with multiple detectors.

astro-ph.IM↗

Prospects for measuring supermassive black hole masses with future extremely large telescopes

The next generation of giant-segmented mirror telescopes ($>$ 20 m) will enable us to observe galactic nuclei at much higher angular resolution and sensitivity than ever before. These capabilities will introduce a revolutionary shift in our understanding of the origin and evolution of supermassive black holes by enabling more precise black hole mass measurements in a mass range that is unreachable today. We present simulations and predictions of the observations of nuclei that will be made with the Thirty Meter Telescope (TMT) and the adaptive optics assisted integral-field spectrograph IRIS, which is capable of diffraction-limited spectroscopy from $Z$ band (0.9 $μ$m) to $K$ band (2.2 $μ$m). These simulations, for the first time, use realistic values for the sky, telescope, adaptive optics system, and instrument, to determine the expected signal-to-noise ratio of a range of possible targets spanning intermediate mass black holes of $\sim10^4$ \msun to the most massive black holes known today of $>10^{10}$ $M_\odot$. We find that IRIS will be able to observe Milky Way-mass black holes out the distance of the Virgo cluster, and will allow us to observe many more brightest cluster galaxies where the most massive black holes are thought to reside. We also evaluate how well the kinematic moments of the velocity distributions can be constrained at the different spectral resolutions and plate scales designed for IRIS. We find that a spectral resolution of $\sim8000$ will be necessary to measure the masses of intermediate mass black holes. By simulating the observations of galaxies found in SDSS DR7, we find that over $10^5$ massive black holes will be observable at distances between $0.005 < z < 0.18$ with the estimated sensitivity and angular resolution provided by access to $Z$-band (0.9 $μ$m) spectroscopy from IRIS and the TMT adaptive optics system. (Abridged)

astro-ph.GA↗

Efficiency Measurements and Installation of a New Grating for the OSIRIS Spectrograph at Keck Observatory

OSIRIS is a near-infrared integral field spectrograph operating behind the adaptive optics system at W. M. Keck Observatory. While OSIRIS has been a scientifically productive instrument to date, its sensitivity has been limited by a grating efficiency that is less than half of what was expected. The spatially averaged efficiency of the old grating, weighted by error, is measured to be 39.5 +/- 0.8 % at λ = 1.310 μm, with large field dependent variation of 11.7 % due to efficiency variation across the grating surface. Working with a new vendor, we developed a more efficient and uniform grating with a weighted average efficiency at λ = 1.310 μm of 78.0 +/- 1.6 %, with field variation of only 2.2 %. This is close to double the average efficiency and five times less variation across the field. The new grating was installed in December 2012, and on- sky OSIRIS throughput shows an average factor of 1.83 improvement in sensitivity between 1 and 2.4 microns. We present the development history, testing, and implementation of this new near-infrared grating for OSIRIS and report the comparison with the predecessors. The higher sensitivities are already having a large impact on scientific studies with OSIRIS.

astro-ph.IM↗

The Circumnuclear Star Formation Environment of NGC 6946: Br-gamma and H2 Results from Keck Integral Field Spectroscopy

We present a 3-dimensional data cube of the K band continuum and the Br-gamma, H2 S(0) and S(1) lines within the central 18.5" x 13.8" (520 pc x 390 pc) region of NGC 6946. Data were obtained using OSIRIS, a near-infrared Integral Field Unit at Keck Observatory, with Laser Guide Star Adaptive Optics. The 0.3" resolution allows us to investigate the stellar bulge and the forming star clusters in the nuclear region on 10 parsec scales. We detect giant HII regions associated with massive young star clusters in the nuclear spiral/ring (R ~ 30pc) and in the principal shocks along the nuclear bar. Comparisons of the Br-gamma fluxes with Pa-alpha line emission and radio continuum indicate A_K ~ 3, A_V ~ 25 for the nuclear star forming regions. The most luminous HII regions are restricted to within 70pc of the center, despite the presence of high gas columns at larger radii (R ~ 200pc). H2 emission is restricted to clouds within R ~ 60pc of the center, and in this sense resembles the distribution of the HCN line emission. We propose that gas-assisted migration of the young star clusters is contributing to the buildup of the nuclear bar and nuclear star cluster (R < 30pc) in this galaxy.

astro-ph.CO↗

NIR imaging spectroscopy of the inner few arcseconds of NGC 4151 with OSIRIS at Keck

We present H- and K-band data from the inner arcsecond of the Seyfert 1.5 galaxy NGC 4151 obtained with the adaptive optics assisted near-infrared imaging field spectrograph OSIRIS at the Keck Observatory. We present the morphology and dynamics of most species detected but focus on the morphology and dynamics of the narrow line region (as traced by emission of [FeII] λ1.644μm), the interplay between plasma ejected from the nucleus (as traced by 21 cm continuum radio data) and hot H2 gas and characterize the detected nuclear HeI$λ2.058 μm absorption feature as a narrow absorption line (NAL) phenomenon.

astro-ph.CO↗

Stellar Populations in the Central 0.5 pc of the Galaxy I: A New Method for Constructing Luminosity Functions and Surface-Density Profiles

We present new high angular resolution near-infrared spectroscopic observations of the nuclear star cluster surrounding the Milky Way's central supermassive black hole. Using the integral-field spectrograph OSIRIS on Keck II behind the laser-guide-star adaptive optics system, this spectroscopic survey enables us to separate early-type (young, 4-6 Myr) and late-type (old, >1 Gyr) stars with a completeness of 50% down to K' = 15.5 mag, which corresponds to ~10 \msun for the early-type stars. This work increases the radial extent of reported OSIRIS/Keck measurements by more than a factor of 3 from 4" to 14" (0.16 pc to 0.56 pc), along the projected disk of young stars. For our analysis, we implement a new method of completeness correction using a combination of star-planting simulations and Bayesian inference. We assign probabilities for the spectral type of every source detected in deep imaging down to K' = 15.5 mag using information from spectra, simulations, number counts, and the distribution of stars. The inferred radial surface-density profiles, $Σ(R) \propto R^{-Γ}$, for the young stars and late-type giants are consistent with earlier results ($Γ_{early} = 0.93 \pm 0.09$, $Γ_{late} = 0.16 \pm 0.07$). The late-type surface-density profile is approximately flat out to the edge of the survey. While the late-type stellar luminosity function is consistent with the Galactic bulge, the completeness-corrected luminosity function of the early-type stars has significantly more young stars at faint magnitudes compared to previous surveys with similar depth. This luminosity function indicates that the corresponding mass function of the young stars is likely less top-heavy than that inferred from previous surveys.

astro-ph.SR↗

Dynamical Measurements of Black Hole Masses in Four Brightest Cluster Galaxies at 100 Mpc

We present stellar kinematics and orbit superposition models for the central regions of four Brightest Cluster Galaxies (BCGs), based upon integral-field spectroscopy at Gemini, Keck, and McDonald Observatories. Our integral-field data span radii from < 100 pc to tens of kpc. We report black hole masses, M_BH, of 2.1 +/- 1.6 x 10^10 M_Sun for NGC 4889, 9.7 + 3.0 - 2.6 x 10^9 M_Sun for NGC 3842, and 1.3 + 0.5 - 0.4 x 10^9 M_Sun for NGC 7768. For NGC 2832 we report an upper limit of M_BH < 9 x 10^9 M_Sun. Stellar orbits near the center of each galaxy are tangentially biased, on comparable spatial scales to the galaxies' photometric cores. We find possible photometric and kinematic evidence for an eccentric torus of stars in NGC 4889, with a radius of nearly 1 kpc. We compare our measurements of M_BH to the predicted black hole masses from various fits to the relations between M_BH and stellar velocity dispersion, luminosity, or stellar mass. The black holes in NGC 4889 and NGC 3842 are significantly more massive than all dispersion-based predictions and most luminosity-based predictions. The black hole in NGC 7768 is consistent with a broader range of predictions.

astro-ph.CO↗

Two ten-billion-solar-mass black holes at the centres of giant elliptical galaxies

Observational work conducted over the last few decades indicates that all massive galaxies have supermassive black holes at their centres. Although the luminosities and brightness fluctuations of quasars in the early Universe suggest that some are powered by black holes with masses greater than 10 billion solar masses, the remnants of these objects have not been found in the nearby Universe. The giant elliptical galaxy Messier 87 hosts the hitherto most massive known black hole, which has a mass of 6.3 billion solar masses. Here we report that NGC 3842, the brightest galaxy in a cluster at a distance from Earth of 98 megaparsecs, has a central black hole with a mass of 9.7 billion solar masses, and that a black hole of comparable or greater mass is present in NGC 4889, the brightest galaxy in the Coma cluster (at a distance of 103 megaparsecs). These two black holes are significantly more massive than predicted by linearly extrapolating the widely-used correlations between black hole mass and the stellar velocity dispersion or bulge luminosity of the host galaxy. Although these correlations remain useful for predicting black hole masses in less massive elliptical galaxies, our measurements suggest that different evolutionary processes influence the growth of the largest galaxies and their black holes.

astro-ph.CO↗

The Black Hole Mass in Brightest Cluster Galaxy NGC 6086

We present the first direct measurement of the central black hole mass, M_BH, in NGC 6086, the Brightest Cluster Galaxy (BCG) in Abell 2162. Our investigation demonstrates for the first time that stellar dynamical measurements of M_BH in BCGs are possible beyond the nearest few galaxy clusters. We observed NGC 6086 with laser guide star adaptive optics and the integral-field spectrograph (IFS) OSIRIS at the W.M. Keck Observatory, and with the seeing-limited IFS GMOS-N at Gemini Observatory North. We combined the two IFS data sets with existing major-axis kinematics, and used axisymmetric stellar orbit models to determine M_BH and the R-band stellar mass-to-light ratio, M*/L_R. We find M_BH = 3.6(+1.7)(-1.1) x 10^9 M_Sun and M*/L_R = 4.6(+0.3)(-0.7) M_Sun/L_Sun (68% confidence), from models using the most massive dark matter halo allowed within the gravitational potential of the host cluster. Models fitting only IFS data confirm M_BH ~ 3 x 10^9 M_Sun and M*/L_R ~ 4 M_Sun/L_Sun, with weak dependence on the dark matter halo structure. When data out to 19 kpc are included, the unrealistic omission of dark matter causes the best-fit black hole mass to decrease dramatically, to 0.6 x 10^9 M_Sun, and the best-fit stellar mass-to-light ratio to increase to 6.7 M_Sun/L_Sun. The latter value is at further odds with stellar population studies favoring M*/L ~ 2 M_Sun/L_Sun,R. Biases from dark matter omission could extend to dynamical models of other galaxies with central stellar cores, and new measurements of M_BH from models with dark matter could steepen the empirical scaling relationships between black holes and their host galaxies.

astro-ph.CO↗

The Infrared Imaging Spectrograph (IRIS) for TMT: Instrument Overview

We present an overview of the design of IRIS, an infrared (0.85 - 2.5 micron) integral field spectrograph and imaging camera for the Thirty Meter Telescope (TMT). With extremely low wavefront error (<30 nm) and on-board wavefront sensors, IRIS will take advantage of the high angular resolution of the narrow field infrared adaptive optics system (NFIRAOS) to dissect the sky at the diffraction limit of the 30-meter aperture. With a primary spectral resolution of 4000 and spatial sampling starting at 4 milliarcseconds, the instrument will create an unparalleled ability to explore high redshift galaxies, the Galactic center, star forming regions and virtually any astrophysical object. This paper summarizes the entire design and basic capabilities. Among the design innovations is the combination of lenslet and slicer integral field units, new 4Kx4k detectors, extremely precise atmospheric dispersion correction, infrared wavefront sensors, and a very large vacuum cryogenic system.

astro-ph.IM↗

The infrared imaging spectrograph (IRIS) for TMT: sensitivities and simulations

We present sensitivity estimates for point and resolved astronomical sources for the current design of the InfraRed Imaging Spectrograph (IRIS) on the future Thirty Meter Telescope (TMT). IRIS, with TMT's adaptive optics system, will achieve unprecedented point source sensitivities in the near-infrared (0.84 - 2.45 μm) when compared to systems on current 8-10m ground based telescopes. The IRIS imager, in 5 hours of total integration, will be able to perform a few percent photometry on 26 - 29 magnitude (AB) point sources in the near-infrared broadband filters (Z, Y, J, H, K). The integral field spectrograph, with a range of scales and filters, will achieve good signal-to-noise on 22 - 26 magnitude (AB) point sources with a spectral resolution of R=4,000 in 5 hours of total integration time. We also present simulated 3D IRIS data of resolved high-redshift star forming galaxies (1 < z < 5), illustrating the extraordinary potential of this instrument to probe the dynamics, assembly, and chemical abundances of galaxies in the early universe. With its finest spatial scales, IRIS will be able to study luminous, massive, high-redshift star forming galaxies (star formation rates ~ 10 - 100 M yr-1) at ~100 pc resolution. Utilizing the coarsest spatial scales, IRIS will be able to observe fainter, less massive high-redshift galaxies, with integrated star formation rates less than 1 M yr-1, yielding a factor of 3 to 10 gain in sensitivity compared to current integral field spectrographs. The combination of both fine and coarse spatial scales with the diffraction-limit of the TMT will significantly advance our understanding of early galaxy formation processes and their subsequent evolution into presentday galaxies.

astro-ph.IM↗

The infrared imaging spectrograph (IRIS) for TMT: the science case

The InfraRed Imaging Spectrograph (IRIS) is a first-light instrument being designed for the Thirty Meter Telescope (TMT). IRIS is a combination of an imager that will cover a 16.4" field of view at the diffraction limit of TMT (4 mas sampling), and an integral field unit spectrograph that will sample objects at 4-50 mas scales. IRIS will open up new areas of observational parameter space, allowing major progress in diverse fields of astronomy. We present the science case and resulting requirements for the performance of IRIS. Ultimately, the spectrograph will enable very well-resolved and sensitive studies of the kinematics and internal chemical abundances of high-redshift galaxies, shedding light on many scenarios for the evolution of galaxies at early times. With unprecedented imaging and spectroscopy of exoplanets, IRIS will allow detailed exploration of a range of planetary systems that are inaccessible with current technology. By revealing details about resolved stellar populations in nearby galaxies, it will directly probe the formation of systems like our own Milky Way. Because it will be possible to directly characterize the stellar initial mass function in many environments and in galaxies outside of the the Milky Way, IRIS will enable a greater understanding of whether stars form differently in diverse conditions. IRIS will reveal detailed kinematics in the centers of low-mass galaxies, allowing a test of black hole formation scenarios. Finally, it will revolutionize the characterization of reionization and the first galaxies to form in the universe.

astro-ph.IM↗