SearcharxivSearch

arXiv subjects

Sheng Lei

Publications and source records attributed to Sheng Lei.

9 recordsLinked to original sources

Accurate Calculation of Switching Events in Electromagnetic Transient Simulation Considering State Variable Discontinuities

Accurate calculation of switching events is important for electromagnetic transient simulation to obtain reliable results. The common presumption of continuous differential state variables could prevent the accurate calculation, thus leading to unreliable results. This paper explores accurately calculating switching events without presuming continuous differential state variables. Possibility of the calculation is revealed by the proposal of related methods. Feasibility and accuracy of the proposed methods are demonstrated and analyzed via numerical case studies.

eess.SY

On Time Stepping Schemes Considering Switching Behaviors for Power System Electromagnetic Transient Simulation

Several difficulties will appear when typical electromagnetic transient simulation, using the implicit trapezoidal method and fixed step sizes, is applied to power systems with switching behaviors. These difficulties are addressed by different aspects of time stepping schemes in the literature. This paper first details the different aspects and reviews corresponding methods. Some misunderstanding in the literature is clarified. Issues that may be encountered by the existing methods are concurrently revealed. Based on the detailed review, the paper then puts forward a novel time stepping scheme which fully addresses the difficulties. The effectiveness of the proposed scheme is demonstrated via numerical case studies.

eess.SY

Proper Selection of Obreshkov-Like Numerical Integrators Used as Numerical Differentiators for Power System Transient Simulation

Obreshkov-like numerical integrators have been widely applied to power system transient simulation. Misuse of the numerical integrators as numerical differentiators may lead to numerical oscillation or bias. Criteria for Obreshkov-like numerical integrators to be used as numerical differentiators are proposed in this paper to avoid these misleading phenomena. The coefficients of a numerical integrator for the highest order derivative turn out to determine its suitability. Some existing Obreshkov-like numerical integrators are examined under the proposed criteria. It is revealed that the notorious numerical oscillations induced by the implicit trapezoidal method cannot always be eliminated by using the backward Euler method for a few time steps. Guided by the proposed criteria, a frequency response optimized integrator considering second order derivative is put forward which is suitable to be used as a numerical differentiator. Theoretical observations are demonstrated in time domain via case studies. The paper points out how to properly select the numerical integrators for power system transient simulation and helps to prevent their misuse.

math.NA

Improved Method for Dealing with Discontinuities in Power System Transient Simulation Based on Frequency Response Optimized Integrators Considering Second Order Derivative

Potential disagreement in the result induced by discontinuities is revealed in this paper between a novel power system transient simulation scheme using numerical integrators considering second order derivative and conventional ones using numerical integrators considering first order derivative. The disagreement is due to the formula of the different numerical integrators. An improved method for dealing with discontinuities in the novel transient simulation scheme is proposed to resolve the disagreement. The effectiveness of the improved method is demonstrated and verified via numerical case studies. Although the disagreement is studied on and the improved method is proposed for a particular transient simulation scheme, similar conclusions also apply to other ones using numerical integrators considering high order derivative.

eess.SY

Transient Simulation of Grid-Feeding Converter System for Stability Studies Using Frequency Response Optimized Integrators

A grid-feeding converter system is added to a novel power system transient simulation scheme based on frequency response optimized integrators considering second order derivative. The converter system and its implementation in the simulation scheme are detailed. Case studies verify the accuracy and efficiency of the simulation scheme. Furthermore, this paper proposes and justifies extending the simulation scheme by integrating commonly used numerical integrators considering first order derivative for part of the studied system. The proposed extension has an insignificant impact on the accuracy of the simulation scheme while significantly enhancing its efficiency. It also reduces the development burden in adding new devices.

eess.SY

Multistep Frequency Response Optimized Integrators and Their Application to Accelerating a Power System Transient Simulation Scheme

This paper proposes several explicit and implicit multistep frequency response optimized integrators considering first or second order derivative. A prediction-based method aiming at accelerating a novel power system transient simulation scheme without impacting its accuracy is further put forward utilizing the proposed numerical integrators and some others available in the literature. Case studies verify the effectiveness of the proposed prediction method. Although they are utilized to accelerate the simulation scheme in this paper, the proposed numerical integrators are in fact general-purpose and can be applied to other areas.

eess.SY

Studies on Frequency Response Optimized Integrators Considering Second Order Derivative

This paper presents comprehensive studies on frequency response optimized integrators considering second order derivative regarding their numerical error, numerical stability and transient performance. Frequency domain error analysis is conducted on these numerical integrators to reveal their accuracy. Numerical stability of the numerical integrators is investigated. Interesting new types of numerical stability are recognized. Transient performance of the numerical integrators is defined to qualitatively characterize their ability to track fast decaying transients. This property is related to unsatisfactory phenomena such as numerical oscillation which frequently appear in time domain simulation of circuits and systems. Transient performance analysis of the numerical integrators is provided. Theoretical observations from the analysis of the numerical integrators are verified via time domain case studies.

math.NA

Initialization Process of a Power System Transient Simulation Scheme for Stability Studies

The initialization process of a novel power system transient simulation scheme for stability studies is put forward, by further developing a "time-domain harmonic power-flow algorithm". The initialization process is formulated as an algebraic problem to ensure that the power system under study is in steady state and operated at a specified operating point, at the beginning of a transient simulation run. The algebraic problem is then solved efficiently by a preconditioned finite difference Newton-GMRES method. Case studies verify the validity and efficiency of the initialization process. The proposed initialization process is general-purpose and can be applied to other power system transient simulation schemes.

eess.SY

Efficient Power System Transient Simulation Based on Frequency Response Optimized Integrators Considering Second Order Derivative

Frequency response optimized integrators considering second order derivative are proposed in this paper. Based on the proposed numerical integrators, and others which also consider second order derivative, this paper puts forward a novel power system transient simulation scheme. Instead of using a unique numerical integrator, the proposed simulation scheme chooses proper ones according to the dominant frequency component of the differential state variables. With the proposed simulation scheme, computational efficiency is improved by using large step sizes without sacrificing accuracy. Numerical case studies demonstrate the validity and efficiency of the simulation scheme.

eess.SY