SearcharxivSearch

arXiv subjects

Sheng-Jui Chen

Publications and source records attributed to Sheng-Jui Chen.

9 recordsLinked to original sources

Axion Search with Q & A Experiment

Dark matter is a focused issue in galactic evolution and cosmology. Axion is a viable particle candidate for dark matter. Its interaction with photon is an effective way to detect it, e.g., pseudoscalar-photon interaction will generate vacuum dichroism in a magnetic field. Motivated to measure the QED vacuum birefringence and to detect pseudoscalar-photon interaction, we started to build up the Q & A experiment (QED [Quantum Electrodynamics] and Axion experiment) in 1994. In this talk, we first give a brief historical account of planet hunting and dark matter evidence. We then review our 3.5 m Fabry-Perot interferometer together with our results of measuring vacuum dichroism and gaseous Cotton-Mouton effects. Our first results give (-0.2 $\pm$ 2.8) $\times$ 10$^{-13}$ rad/pass, at 2.3 T with 18,700 passes through a 0.6 m long magnet, for vacuum dichroism measurement. We are upgrading our interferometer to 7 m arm-length with a new 1.8 m 2.3 T permanent magnet capable of rotation up to 13 cycles per second. We aim at 10 nrad/Hz$^{1/2}$ optical sensitivity with 532 nm cavity finesse around 100,000. When achieved, vacuum dichroism would be measured to 8.6 $\times$ 10$^{-17}$ rad/pass in about 50 days, and QED birefringence would be measured to 28 %.

physics.ins-det

The status and prospects of the Q & A experiment with some applications

Motivated to measure the QED birefringence and to detect pseudoscalar-photon interaction, we started to build up the Q & A experiment (QED [Quantum Electrodynamics] and Axion experiment) in 1994. In this talk, we first review our 3.5 m Fabry-Perot interferometer together with our results of measuring Cotton-Mouton effects of gases. We are uprading our interferometer to 7 m armlength with a new 1.8 m 2.3 T permanent magnet capable of rotation up to 13 cycles per second. We will use 532 nm Nd:YAG laser as light source with cavity finesse around 100,000, and aim at 10 nrad/Hz^{1/2} optical sensitivity. With all these achieved and the upgrading of vacuum, QED birefringence would be measured to 28% in about 50 days. Along the way, we should be able to improve on the dichroism detection significantly.

physics.ins-det

Measurement of the Cotton-Mouton effect in nitrogen, oxygen, carbon dioxide, argon, and krypton with the Q & A apparatus

Experiments for vacuum birefringence and vacuum dichroism have been set up with high-finesse high magnetic experimental apparatuses, which seem to be ideal for small gaseous Cotton-Mouton effect (CME) measurements. PVLAS Collaboration has measured CMEs in krypton, xenon and neon at the wavelength of 1064 nm. In this Letter, we report on our measurement of CMEs in nitrogen, oxygen, carbon dioxide, argon, and krypton at the same wavelength in a magnetic field B = 2.3 T at pressure P = 0.5-300 Torr and temperature T = 295-298 K. Our results agree with the PVLAS results in the common cases.

physics.chem-ph

Nanonewton force generation and detection based on a sensitive torsion pendulum

In this paper, we introduce the experiment based on a sensitive torsion pendulum for measuring and calibrating small forces at nanonewton scale. The force standard for calibration is the universal gravitation between four masses separated by known distances. It is realized by two test masses suspended as the part of torsion pendulum and two source masses on a rotation table. Two force generation mechanisms, optical force from radiation pressure and electrostatic force by capacitive actuation unit, are designed and will be calibrated by the gravitation force. We present our recent results of radiation pressure measurements, and describe the design of capacitive displacement sensing/actuating unit.

gr-qc

Q & A Experiment to Search for Vacuum Dichroism, Pseudoscalar-Photon Interaction and Millicharged Fermions

A number of experiments are underway to detect vacuum birefringence and dichroism -- PVLAS, Q & A, and BMV. Recently, PVLAS experiment has observed optical rotation in vacuum by a magnetic field (vacuum dichroism). Theoretical interpretations of this result include a possible pseudoscalar-photon interaction and the existence of millicharged fermions. Here, we report the progress and first results of Q & A (QED [quantum electrodynamics] and Axion) experiment proposed and started in 1994. A 3.5-m high-finesse (around 30,000) Fabry-Perot prototype detector extendable to 7-m has been built and tested. We use X-pendulums and automatic control schemes developed by the gravitational-wave detection community for mirror suspension and cavity control. To polarize the vacuum, we use a 2.3-T dipole permanent magnet, with 27-mm-diameter clear borehole and 0.6-m field length,. In the experiment, the magnet is rotated at 5-10 rev/s to generate time-dependent polarization signal with twice the rotation frequency. Our ellipsometer/polarization-rotation-detection-system is formed by a pair of Glan-Taylor type polarizing prisms with extinction ratio lower than 10-8 together with a polarization modulating Faraday Cell with/without a quarter wave plate. We made an independent calibration of our apparatus by performing a measurement of gaseous Cotton-Mouton effect of nitrogen. We present our first experimental results and give a brief discussion of our experimental limit on pseudo-scalar-photon interaction and millicharged fermions.

hep-ex

Suspension of the fiber mode-cleaner launcher and measurement of the high extinction-ratio (10^{-9}) ellipsometer for the Q & A experiment

The Q & A experiment, first proposed and started in 1994, provides a feasible way of exploring the quantum vacuum through the detection of vacuum birefringence effect generated by QED loop diagram and the detection of the polarization rotation effect generated by photon-interacting (pseudo-)scalar particles. Three main parts of the experiment are: (1) Optics System (including associated Electronic System) based on a suspended 3.5-m high finesse Fabry-Perot cavity, (2) Ellipsometer using ultra-high extinction-ratio polarizer and analyzer, and (3) Magnetic Field Modulation System for generating the birefringence and the polarization rotation effect. In 2002, the Q & A experiment achieved the Phase I sensitivity goal. During Phase II, we set (i) to improve the control system of the cavity mirrors for suppressing the relative motion noise, (ii) to enhance the birefringence signal by setting-up a 60-cm long 2.3 T transverse permanent magnet rotatable to 10 rev/s, (iii) to reduce geometrical noise by inserting a polarization-maintaining optical fiber (PM fiber) as a mode cleaner, and (iv) to use ultra-high extinction-ratio (10^{-9}) polarizer and analyzer for ellipsometry. Here we report on (iii) & (iv); specifically, we present the properties of the PM-fiber mode-cleaner, the transfer function of its suspension system, and the result of our measurement of high extinction-ratio polarizer and analyzer.

physics.ins-det

Ellipsometry noise spectrum, suspension transfer function measurement and closed-loop control of the suspension system in the Q & A experiment

The Q & A experiment, aiming at the detection of vacuum birefringence predicted by quantum electrodynamics, consists mainly of a suspended 3.5 m Fabry-Perot cavity, a rotating permanent dipole magnet and an ellipsometer. The 2.3 T magnet can rotate up to 10 rev/s, introducing an ellipticity signal at twice the rotation frequency. The X-pendulum gives a good isolation ratio for seismic noise above its main resonant frequency 0.3 Hz. At present, the ellipsometry noise decreases with frequency, from 1*10^{-5} rad Hz^{-1/2} at 5 Hz, 2*10^{-6} rad Hz^{-1/2} at 20 Hz to 5*10^{-7} rad Hz^{-1/2} at 40 Hz. The shape of the noise spectrum indicates possible improvement can be made by further reducing the movement between the cavity mirrors. From the preliminary result of yaw motion alignment control, it can be seen that some peaks due to yaw motion of the cavity mirror was suppressed. In this paper, we first give a schematic view of the Q & A experiment, and then present the measurement of transfer function of the compound X-pendulum-double pendulum suspension. A closed-loop control was carried out to verify the validity of the measured transfer functions. The ellipsometry noise spectra with and without yaw alignment control and the newest improvement is presented.

physics.ins-det

Improving ellipticity detection sensitivity for the Q & A vacuum birefringence experiment

Q & A (quantum electrodynamics test and search for axion) experiment was first proposed in 1994 and a 3.5 m high-finesse Fabry-Perot prototype detector extendable to 7 m has been built and tested. We now enter into the 2nd phase of improving the ellipticity detection sensitivity. We present our scheme, compare with other ongoing experiments, analyze the displacement spectra of our suspension system, and use them for designing automatic alignment control to improve the ellipticicy detection sensitivity. To improve ellipsometry resolution, we use new polarizers of extinction ratio smaller than 10^{-8}.

hep-ex

Building a 3.5 m prototype interferometer for the Q & A vacuum birefringence experiment and high precision ellipsometry

We have built and tested a 3.5 m high-finesse Fabry-Perot prototype inteferometer with a precision ellipsometer for the QED test and axion search (Q & A) experiment. We use X-pendulum-double-pendulum suspension designs and automatic control schemes developed by the gravitational-wave detection community. Verdet constant and Cotton-Mouton constant of the air are measured as a test. Double modulation with polarization modulation 100 Hz and magnetic-field modulation 0.05 Hz gives 10^{-7} rad phase noise for a 44-minute integration.

physics.ins-det