SearcharxivSearch

arXiv subjects

Shengming He

Publications and source records attributed to Shengming He.

10 recordsLinked to original sources

A Gaseous Time Projection Chamber with Micromegas Readout for Low Radioactive Material Screening

Low radioactive material screening is becoming essential for rare event search experiments, such as neutrinoless double beta decay and dark matter searches in underground laboratories. A gaseous time projection chamber (TPC) can be used for such purposes with large active areas and high efficiency. A gaseous TPC with a Micromegas readout plane of approximately 20$\times$20 cm$^2$ is successfully constructed for surface alpha contamination measurements. We have characterized the energy resolution, gain stability, and tracking capability with calibration sources. With the unique track-related background suppression cuts of the gaseous TPC, we have established that the alpha background rate of the TPC is 0.13$\pm$0.03 $\mu$Bq/cm$^2$, comparable to the leading commercial solutions.

physics.ins-det

Screener3D: a Gaseous Time Projection Chamber for Ultra-low Radioactive Material Screening

In experiments searching for rare signals, background events from the detector itself are some of the major factors limiting search sensitivity.Screening for ultra-low radioactive detector materials is becoming ever more essential. We propose to develop a gaseous time projection chamber (TPC) with a Micromegas readout for radio screening. The TPC records three-dimensional trajectories of charged particles emitted from a flat sample placed in the active volume of the detector. The detector can distinguish the origin of an event and identify the particle types with information from trajectories, which significantly increases the screening sensitivity. For $\alpha$ particles from the sample surface, we observe that our proposed detector can reach a sensitivity higher than 100 $\mu$Bq$\cdot$m$^{-2}$ within two days.

physics.ins-det

Horizontal Position Reconstruction in PandaX-II

Dual-phase noble-gas time projection chambers (TPCs) have improved the sensitivities for dark matter direct search in past decades. The capability of TPCs to reconstruct 3-D vertexes of keV scale recoilings is one of the most advantageous features. In this work, we develop two horizontal position reconstruction algorithms for the PandaX-II dark matter search experiment using the dual-phase liquid xenon TPC. Both algorithms are optimized by the $^{83m}$Kr calibration events and use photon distribution of ionization signals among photomultiplier tubes to infer the positions. According to the events coming from the gate electrode, the uncertainties in the horizontal positions are 3.4 mm (3.9 mm) in the analytical (simulation-based) algorithm for an ionization signal with several thousand photon electrons in the center of the TPC

physics.ins-det

Constraining self-interacting dark matter with the full dataset of PandaX-II

Self-interacting Dark Matter (SIDM) is a leading candidate proposed to solve discrepancies between predictions of the prevailing cold dark matter theory and observations of galaxies. Many SIDM models predict the existence of a light force carrier that mediate strong dark matter self-interactions. If the mediator couples to the standard model particles, it could produce characteristic signals in dark matter direct detection experiments. We report searches for SIDM models with a light mediator using the full dataset of the PandaX-II experiment, based on a total exposure of 132 tonne-days. No significant excess over background is found, and our likelihood analysis leads to a strong upper limit on the dark matter-nucleon coupling strength. We further combine the PandaX-II constraints and those from observations of the light element abundances in the early universe, and show that direct detection and cosmological probes can provide complementary constraints on dark matter models with a light mediator.

hep-ex

Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources

We have developed a low-energy electron recoil (ER) calibration method with $^{220}$Rn for the PandaX-II detector. $^{220}$Rn, emanated from natural thorium compounds, was fed into the detector through the xenon purification system. From 2017 to 2019, we performed three dedicated calibration campaigns with different radon sources. We studied the detector response to $\alpha$, $\beta$, and $\gamma$ particles with focus on low energy ER events. During the runs in 2017 and 2018, the amount of radioactivity of $^{222}$Rn were on the order of 1\% of that of $^{220}$Rn and thorium particulate contamination was negligible, especially in 2018. We also measured the background contribution from $^{214}$Pb for the first time in PandaX-II with the help from a $^{222}$Rn injection. Calibration strategy with $^{220}$Rn and $^{222}$Rn will be implemented in the upcoming PandaX-4T experiment and can be useful for other xenon-based detectors as well.

physics.ins-det

PandaX-II Constraints on Spin-Dependent WIMP-Nucleon Effective Interactions

We present PandaX-II constraints on candidate WIMP-nucleon effective interactions involving the nucleon or WIMP spin, including, in addition to standard axial spin-dependent (SD) scattering, various couplings among vector and axial currents, magnetic and electric dipole moments, and tensor interactions. The data set corresponding to a total exposure of 54-ton-days is reanalyzed to determine constraints as a function of the WIMP mass and isospin coupling. We obtain WIMP-nucleon cross section bounds of $\rm 1.6 \times 10^{-41} cm^2$ and $\rm 9.0 \times 10^{-42} cm^2$ ($90\%$ c.l.) for neutron-only SD and tensor coupling, respectively, for a mass $M_\mathrm{WIMP} \sim {\rm 40~GeV}/c^2$. The SD limits are the best currently available for $M_\mathrm{WIMP} > {\rm 40~GeV}/c^2$. We show that PandaX-II has reached a sensitivity sufficient to probe a variety of other candidate spin-dependent interactions at the weak scale.

hep-ex

Dark matter direct search sensitivity of the PandaX-4T experiment

The PandaX-4T experiment, a four-ton scale dark matter direct detection experiment, is being planned at the China Jinping Underground Laboratory. In this paper we present a simulation study of the expected background in this experiment. In a 2.8-ton fiducial mass and the signal region between 1 to 10 keV electron equivalent energy, the total electron recoil background is found to be 4.9x10^{-5} /(kg day keV). The nuclear recoil background in the same region is 2.8x10^{-7}/(kg day keV). With an exposure of 5.6 ton-years, the sensitivity of PandaX-4T could reach a minimum spin-independent dark matter-nucleon cross section of 6x10^{-48} cm^{2} at a dark matter mass of 40 GeV/c^{2}.

physics.ins-det

Constraining Dark Matter Models with a Light Mediator from PandaX-II Experiment

We search for nuclear recoil signals of dark matter models with a light mediator in PandaX-II, a direct detection experiment in China Jinping underground Laboratory. Using data collected in 2016 and 2017 runs, corresponding to a total exposure of 54 ton day, we set upper limits on the zero-momentum dark matter-nucleon cross section. These limits have a strong dependence on the mediator mass when it is comparable to or below the typical momentum transfer. We apply our results to constrain self-interacting dark matter models with a light mediator mixing with standard model particles, and set strong limits on the model parameter space for the dark matter mass ranging from $5~{\rm GeV}$ to $10~{\rm TeV}$.

hep-ph

Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment

We report a new search of weakly interacting massive particles (WIMPs) using the combined low background data sets in 2016 and 2017 from the PandaX-II experiment in China. The latest data set contains a new exposure of 77.1 live day, with the background reduced to a level of 0.8$\times10^{-3}$ evt/kg/day, improved by a factor of 2.5 in comparison to the previous run in 2016. No excess events were found above the expected background. With a total exposure of 5.4$\times10^4$ kg day, the most stringent upper limit on spin-independent WIMP-nucleon cross section was set for a WIMP with mass larger than 100 GeV/c$^2$, with the lowest exclusion at 8.6$\times10^{-47}$ cm$^2$ at 40 GeV/c$^2$.

astro-ph.CO

Exploring the dark matter inelastic frontier with 79.6 days of PandaX-II data

We report here the results of searching for inelastic scattering of dark matter (initial and final state dark matter particles differ by a small mass splitting) with nucleon with the first 79.6-day of PandaX-II data (Run 9). We set the upper limits for the spin independent WIMP-nucleon scattering cross section up to a mass splitting of 300 keV/c$^2$ at two benchmark dark matter masses of 1 and 10 TeV/c$^2$.

hep-ex