SearcharxivSearch

arXiv subjects

Shifeng Sun

Publications and source records attributed to Shifeng Sun.

2 recordsLinked to original sources

Getting it right: Methods for risk ratios and risk differences cluster randomized trials with a small number of clusters

Most cluster randomized trials (CRTs) randomize fewer than 30-40 clusters in total. When performing inference for such ``small'' CRTs, it is important to use methods that appropriately account for the small sample size. When the generalized estimating equations (GEE) approach is used for analysis of ``small'' CRTs, the robust variance estimator from GEE is biased downward and therefore bias-corrected standard errors should be used. Moreover, in order to avoid inflated Type I error, an appropriate bias-corrected standard error should be paired with the t- rather than Z-statistic when making inference about a single-parameter intervention effect. Although several bias-correction methods (including Kauermann and Carroll (KC), Mancl and DeRouen (MD), Morel, Bokossa, and Neerchal (MBN), and the average of KC and MD (AVG)) have been evaluated for inference for odds ratios, their finite-sample behavior in ``small'' CRTs with few clusters has not been thoroughly investigated for risk ratios and risk differences. The current article aims to fill the gap by including analysis via binomial, Poisson and Gaussian models and for a broad spectrum of scenarios. Analysis is via binomial and Poisson models (using log and identity link for risk and differences measures, respectively). We additionally explore the use of Gaussian models with identity link for risk differences and adopt the "modified" approach for analysis with misspecified Poisson and Gaussian models. We consider a broad spectrum of scenarios including for rare outcomes, small cluster sizes, high intracluster correlations (ICCs), and high coefficients of variation (CVs) of cluster size.

stat.ME

A semi-empirical response function for Gamma-ray of Scintillation detector based on physical interaction mechanism

Scintillation detector has lower energy resolution for Gamma-ray as compared to semiconductor detector, better spectra analysis method is essential to traditional method. A model for describing the response function of scintillation detector over the range of incident Gamma-ray energies between 0.5 and 1.5 MeV has been established and applied to fitting radiation sources spectra. Each function form for describing the feature of Gamma-ray spectra are based on the analysis of fundamental interaction mechanism. These functions are combined to form a DRF model to fit experiment spectra by weighted least squares fitting method, parameters in this model are obtained simultaneously. Gaussian standard deviation can be calculated out by an individual procedure. Validity of the DRF model is demonstrated by fitting Co-60 and Cs-137 spectra measured by CsI(Tl) detector and comparing them to the normalized equivalent measured spectrum.

physics.ins-det