SearcharxivSearch

arXiv subjects

Shiming Zou

Publications and source records attributed to Shiming Zou.

5 recordsLinked to original sources

Development of a sub-100 ps Time-of-Flight detector with SiPM-readout scintillator for measurement of cosmic muon velocity

Accurate Time-of-Flight (TOF) measurement with sub-100 picosecond resolution is a critical requirement for particle identification in future high-energy physics experiments, such as the Belle II $K_{L}$ and Muon (KLM) detector upgrade. Achieving this precision with large-area Silicon Photomultipliers (SiPMs) is challenging due to the inherent junction capacitance, which degrades signal rise time. In this work, we developed and evaluated a high-time-resolution cosmic ray detector based on plastic scintillators and customized SiPM arrays. To optimize the readout for block-shaped scintillators, we systematically compared different sensor topologies. We demonstrate that a multi-face readout topology, utilizing low-capacitance 4-series (4S) SiPM modules coupled to four faces of the scintillator, achieves an excellent coincidence time resolution of approximately 68 ps, outperforming the $\sim$100 ps resolution of the concentrated 4-series 3-parallel (4S3P) hybrid topology. Furthermore, to validate the system's practical performance, we successfully measured well-known cosmic ray observables, specifically the relativistic muon velocity via TOF reconstruction. These results highlight the potential of the multi-face 4S configuration as a high-precision solution for future TOF detector upgrades.

physics.ins-det

Development of a time calibration system for the KLM upgrade in the Belle II experiment

To meet the stringent time calibration requirements for the Belle II experiment upgrade, particularly for its large-size KL and Muon Detector comprising tens of thousands of scintillator channels with time resolutions better than 100 ps, we developed a compact and high-speed time calibration system. The system utilizes a laser diode as its light source, integrated with a fast pulse laser drive circuit that employs high-speed switching GaN FETs and gate drivers. A prototype was constructed and rigorously evaluated using scintillators, achieving timing resolutions of about 13 ps for a single calibration channel. Furthermore, internal deviations among calibration channels were analyzed, with most measurements remaining within 250 ps. These results highlight the system's precision, scalability, and suitability for large-scale particle physics experiments.

physics.ins-det

R&D of KLM Upgrade for Direct Measurement of Neutral Hadron Momentum via Time-of-Flight in Belle II

Accurate momentum determination of a neutral hadron, such as a KL meson or a neutron, remains a significant challenge in particle physics and nuclear physics experiments. The Belle II experiment presents an opportunity to address this challenge through an upgrade incorporating Time-of-Flight (TOF) capability for its large KL and Muon Detector (KLM). We investigate the feasibility of momentum determination via TOF measurement. To achieve high time resolution for the KLM upgrade, we conduct research and development of cost-effective plastic scintillators in collaboration with GaoNengKeDi Company, and technology utilizing silicon photomultipliers(SiPMs) arrays. A bulk attenuation length of 120 \pm 7 cm has been achieved with a 135 cm-long sample, along with a time resolution of 70 \pm 7 ps at its midpoint. A 50 cm-long scintillator demonstrates an exceptional time resolution of 47 \pm 2 ps. These results highlight the potential of the proposed technology for improving neutral hadron momentum measurements in an upgraded Belle II KLM detector.

physics.ins-det

Scintillation and Timing Performance of a 3at% Yttrium-Doped Barium Fluoride Crystal

We report the scintillation and timing performance of a new developed 200 * 20 mm * 20 mm large size barium fluoride crystal doped with 3at% yttrium (BaF2:Y) to enhance the application for high time resolution. This doping effectively suppresses the slow scintillation component while maintaining most of the fast component, as confirmed by X-ray excited luminescence measurements. The BaF2:Y crystal demonstrated a transmittance of near 90% in the visible spectrum and a light response uniformity parameter of delta = (-2.74 +- 1.15)% when coupled with the tail end. The actual yttrium content varied from 2.1at% near the seed end to 3.7at% at the tail end. The assembled large BaF2:Y detector with silicon photomultipliers exhibited a time resolution of (82.2 +- 2.6) ps using constant fraction discrimination method in a cosmic ray test and (140.1 +- 3.8) ps using a low fixed threshold method in a beam test at Shanghai Synchrotron Radiation Facility with an 1.35 GeV electron beam. These results indicate the significant potential of BaF2:Y crystal for various applications, such as detectors for particle physics and nuclear physics.

physics.ins-det

Design and test for the CEPC muon subdetector based on extruded scintillator and SiPM

A combination of scintillator, wavelength shifting (WLS) fiber, and silicon photomultiplier (SiPM) shows an excellent performance in the `$K_{L}$ and $\mu$ detector (KLM)' of the Belle II experiment. In this study, we present the R&D efforts for a similar detection technology utilizing a new scintillator and SiPM. This technology can be applied to a muon detector for the proposed CEPC experiment. The R&D encompasses the investigation of the performance of a new 150 cm-long scintillator, the NDL SiPM with a sensitive surface of $\times$ 3 mm, or the Hamamatsu MPPC with a sensitive surface of 1.3 mm $\times$ 1.3 mm. Additionally, it includes the construction of a detector strip and the methods employed to achieve excellent light collection. Cosmic ray tests reveal efficient photon collections by NDL SiPM or MPPC, with efficiencies well above 90% using a threshold of 8 p.e.. The time resolutions for hits at the far end of a scintillator strip are better than 1.7 ns. The observed performance lays the foundation for advancing R&D including prototype modules aiming for reference Technical Design Report of CEPC detector recently.

physics.ins-det