SearcharxivSearch

arXiv subjects

Shingo Kazama

Publications and source records attributed to Shingo Kazama.

6 recordsLinked to original sources

Development of a Hermetic Gaseous Xenon Detector for Suppressing External Radon Background

Radon-induced backgrounds, particularly from $^{222}$Rn and its beta-emitting progeny, present a critical challenge for next-generation liquid xenon (LXe) detectors aimed at probing dark matter down to the neutrino fog. To address this, we developed a compact hermetic gaseous xenon (GXe) detector. This device physically isolates the active volume from external radon sources by using a PTFE vessel sealed between two quartz flanges with mechanically compressed ePTFE gaskets. To quantify radon sealing performance, we implemented a dual-loop GXe circulation system and conducted a 670-hour radon-injection measurement campaign. Radon ingress into the hermetic detector was monitored using electrostatic radon detectors and photomultiplier tubes (PMTs). From these two independent measurements, the steady-state ratios of the radon concentrations inside the hermetic detector to those outside were estimated to be $ (1.1 \pm 0.1) \times 10^{-2} $ and $ (1.1 \pm 0.2) \times 10^{-2} $, corresponding to radon-leakage flows of $ (2.9 \pm 0.3) \times 10^{-11} $ and $ (2.6 \pm 0.4) \times 10^{-11} $ $ \thinspace $m$^{3}$ $ \thinspace $ $\mathrm{s}^{-1}$, respectively. An extrapolation to a 60-tonne LXe TPC such as XLZD suggests that the radon leakage could amount to $ 1.2 \times 10^{-2} $ $ \thinspace $mBq, which is negligible compared to the expected natural radon emanation inside the detector, typically 3$ \thinspace $mBq. These results demonstrate that flange-based mechanical sealing provides an effective solution for realizing radon-isolated inner detectors in large-scale LXe experiments.

physics.ins-det

Measurement of the Quantum Efficiency of Electrode Materials for VUV Photons in Liquid Xenon

Light dark matter searches using ionization signals in dual-phase liquid xenon (LXe) time projection chambers (TPCs) are limited by low-energy ionization backgrounds, including those from the photoelectric effect on the electrodes. To address this, we measured the quantum efficiency (QE) of various electrode materials for vacuum ultraviolet (VUV) photons in LXe, including platinum (Pt), stainless steel (SUS304), and magnesium fluoride (MgF$_{2}$)-coated aluminum (Al). Our results show that MgF$_{2}$-coated Al exhibits the lowest QE among the tested materials. The QE for VUV photons with a mean wavelength of 179.5~nm was measured to be $(7.2 \pm 2.3) \times 10^{-5}$, corresponding to a reduction by a factor of 4.4 compared to SUS304, a commonly used electrode material in direct dark matter experiments with LXe. These findings suggest that employing low-QE electrodes can help mitigate photoelectric-induced backgrounds, potentially improving the sensitivity of LXe TPCs in light dark matter searches.

physics.ins-det

Mineral Detection of Neutrinos and Dark Matter. A Whitepaper

Minerals are solid state nuclear track detectors - nuclear recoils in a mineral leave latent damage to the crystal structure. Depending on the mineral and its temperature, the damage features are retained in the material from minutes (in low-melting point materials such as salts at a few hundred degrees C) to timescales much larger than the 4.5 Gyr-age of the Solar System (in refractory materials at room temperature). The damage features from the $O(50)$ MeV fission fragments left by spontaneous fission of $^{238}$U and other heavy unstable isotopes have long been used for fission track dating of geological samples. Laboratory studies have demonstrated the readout of defects caused by nuclear recoils with energies as small as $O(1)$ keV. This whitepaper discusses a wide range of possible applications of minerals as detectors for $E_R \gtrsim O(1)$ keV nuclear recoils: Using natural minerals, one could use the damage features accumulated over $O(10)$ Myr$-O(1)$ Gyr to measure astrophysical neutrino fluxes (from the Sun, supernovae, or cosmic rays interacting with the atmosphere) as well as search for Dark Matter. Using signals accumulated over months to few-years timescales in laboratory-manufactured minerals, one could measure reactor neutrinos or use them as Dark Matter detectors, potentially with directional sensitivity. Research groups in Europe, Asia, and America have started developing microscopy techniques to read out the $O(1) - O(100)$ nm damage features in crystals left by $O(0.1) - O(100)$ keV nuclear recoils. We report on the status and plans of these programs. The research program towards the realization of such detectors is highly interdisciplinary, combining geoscience, material science, applied and fundamental physics with techniques from quantum information and Artificial Intelligence.

astro-ph.IM

Development of Dual-phase Xenon TPC with a Quartz Chamber for Direct Dark Matter Search

The idea of a hermetic quartz chamber in a dual-phase xenon time projection chamber (TPC) has the potential to improve the detector sensitivity for direct dark matter searches in the future. A major challenge facing TPC detectors in future dark matter experiments will be the reduction of the internal background such as $^{222}$Rn and the deterioration of the ionization signal due to electronegative impurities. The hermetic quartz chamber can isolate the TPC's sensitive volume from external interference and is thus expected to prevent contamination caused by the radioactive and electronegative impurities, which originate from outer detector materials. At the Kamioka Observatory in Japan, we developed a TPC with a quartz chamber that contains a $ϕ48 \times 58$ mm volume of liquid xenon. At this development stage, we did not aim at the perfect hermeticity of the quartz chamber. Our aim here is twofold: first, to demonstrate via the use of a calibration source that the presence of quartz materials in the TPC does not impact its operation; and second, to perform quantitative measurements of the TPC's characteristics. We successfully measured electron drift velocities of 1.2--1.7 mm/$μ$s in liquid xenon under electric fields ranging from 75--384 V/cm, and also observed small S2 signals produced by a single ionized electron with a light yield of 16.5 $\pm$ 0.5 PE. These results were consistent with the expected values; therefore, our demonstrations provide a proof of principle for TPCs incorporating a quartz chamber.

physics.ins-det

Detection capability of Migdal effect for argon and xenon nuclei with position sensitive gaseous detectors

Migdal effect is attracting interests because of the potential to enhance the sensitivities of direct dark matter searches to the low mass region. In spite of its great importance, the Migdal effect has not been experimentally observed yet. A realistic experimental approach towards the first observation of the Migdal effect in the neutron scattering was studied with Monte Carlo simulations. In this study, potential background rate was studied together with the event rate of the Migdal effect by a neutron source. It was found that a table-top sized $\sim (30\rm cm )^3$ position-sensitive gaseous detector filled with argon or xenon target gas can detect characteristic signatures of the Migdal effect with sufficient rates (O($10^2\sim10^3$) events/day). A simulation result of a simple experimental set-up showed two significant background sources, namely the intrinsic neutrons and the neutron induced gamma-rays. These background rates were found to be much higher than those of the Migdal effect in the neutron scattering. As a consequence of this study, it is concluded that the experimental observation of the Migdal effect in the neutron scattering can be realized with a good understanding and reduction of the background.

physics.ins-det

A Dual-phase Xenon TPC for Scintillation and Ionisation Yield Measurements in Liquid Xenon

A small-scale, two-phase (liquid/gas) xenon time projection chamber (Xurich II) was designed, constructed and is under operation at the University of Zurich. Its main purpose is to investigate the microphysics of particle interactions in liquid xenon at energies below 50 keV, which are relevant for rare event searches using xenon as target material. Here we describe in detail the detector, its associated infrastructure, and the signal identification algorithm developed for processing and analysing the data. We present the first characterisation of the new instrument with calibration data from an internal 83m-Kr source. The zero-field light yield is 15.0 and 14.0 photoelectrons/keV at 9.4 keV and 32.1 keV, respectively, and the corresponding values at an electron drift field of 1 kV/cm are 10.8 and 7.9 photoelectrons/keV. The charge yields at these energies are 28 and 31 electrons/keV, with the proportional scintillation yield of 24 photoelectrons per one electron extracted into the gas phase, and an electron lifetime of 200 $μ$s. The relative energy resolution, $σ/E$, is 11.9 % and 5.8 % at 9.4 keV and 32.1 keV, respectively using a linear combination of the scintillation and ionisation signals. We conclude with measurements of the electron drift velocity at various electric fields, and compare these to literature values.

astro-ph.IM