Topology-Aware Graph Neural Network-based State Estimation for PMU-Unobservable Power Systems

Traditional optimization-based techniques for time-synchronized state estimation (SE) often suffer from high online computational burden, limited phasor measurement unit (PMU) coverage, and presence of non-Gaussian measurement noise. Although conventional learning-based models have been developed to overcome these challenges, they are negatively impacted by topology changes and real-time data loss. This paper proposes a novel deep geometric learning approach based on graph neural networks (GNNs) to estimate the states of PMU-unobservable power systems. The proposed approach combines graph convolution and multi-head graph attention layers inside a customized end-to-end learning framework to handle topology changes and real-time data loss. An upper bound on SE error as a function of topology change is also derived. Experimental results for different test systems demonstrate superiority of the proposed customized GNN-SE (CGNN-SE) over traditional optimization-based techniques as well as conventional learning-based models in presence of topology changes, PMU failures, bad data, non-Gaussian measurement noise, and large system implementation.

eess.SY

Analytical Verification of Performance of Deep Neural Network Based Time-Synchronized Distribution System State Estimation

Recently, we demonstrated success of a time-synchronized state estimator using deep neural networks (DNNs) for real-time unobservable distribution systems. In this letter, we provide analytical bounds on the performance of that state estimator as a function of perturbations in the input measurements. It has already been shown that evaluating performance based on only the test dataset might not effectively indicate a trained DNN's ability to handle input perturbations. As such, we analytically verify robustness and trustworthiness of DNNs to input perturbations by treating them as mixed-integer linear programming (MILP) problems. The ability of batch normalization in addressing the scalability limitations of the MILP formulation is also highlighted. The framework is validated by performing time-synchronized distribution system state estimation for a modified IEEE 34-node system and a real-world large distribution system, both of which are incompletely observed by micro-phasor measurement units.

cs.LG

Time-Synchronized State Estimation Using Graph Neural Networks in Presence of Topology Changes

Recently, there has been a major emphasis on developing data-driven approaches involving machine learning (ML) for high-speed static state estimation (SE) in power systems. The emphasis stems from the ability of ML to overcome difficulties associated with model-based approaches, such as handling of non-Gaussian measurement noise. However, topology changes pose a stiff challenge for performing ML-based SE because the training and test environments become different when such changes occur. This paper circumvents this challenge by formulating a graph neural network (GNN)-based time-synchronized state estimator that considers the physical connections of the power system during the training itself. The results obtained using the IEEE 118-bus system indicate that the GNN-based state estimator outperforms both the model-based linear state estimator and a data-driven deep neural network-based state estimator in the presence of non-Gaussian measurement noise and topology changes, respectively.

eess.SY

Two-level Robust State Estimation for Multi-Area Power Systems Under Bounded Uncertainties

This paper introduces a two-level robust approach to estimate the unknown states of a large-scale power system while the measurements and network parameters are subjected to uncertainties. The bounded data uncertainty (BDU) considered in the power network is a structured uncertainty which is inevitable in practical systems due to error in transmission lines, inaccurate modelling, unmodeled dynamics, parameter variations, and other various reasons. In the proposed approach, the corresponding network is first decomposed into smaller subsystems (areas), and then a two-level algorithm is presented for state estimation. In this algorithm, at the first level, each area uses a weighted least squares (WLS) technique to estimate its own states based on a robust hybrid estimation utilizing phasor measurement units (PMUs), and at the second level, the central coordinator processes all the results from the subareas and gives a robust estimation of the entire system. The simulation results for IEEE 30-bus test system verifies the accuracy and performance of the proposed multi-area robust estimator.

eess.SY

State and Topology Estimation for Unobservable Distribution Systems using Deep Neural Networks

Time-synchronized state estimation for reconfigurable distribution networks is challenging because of limited real-time observability. This paper addresses this challenge by formulating a deep learning (DL)-based approach for topology identification (TI) and unbalanced three-phase distribution system state estimation (DSSE). Two deep neural networks (DNNs) are trained for time-synchronized DNN-based TI and DSSE, respectively, for systems that are incompletely observed by synchrophasor measurement devices (SMDs) in real-time. A data-driven approach for judicious SMD placement to facilitate reliable TI and DSSE is also provided. Robustness of the proposed methodology is demonstrated by considering non-Gaussian noise in the SMD measurements. A comparison of the DNN-based DSSE with more conventional approaches indicates that the DL-based approach gives better accuracy with smaller number of SMDs.