SearcharxivSearch

arXiv subjects

Sho Uemura

Publications and source records attributed to Sho Uemura.

At least 19 recordsLinked to original sources

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

physics.ins-det

Light-tight skipper-CCDs for X-ray detection in space

Skipper Charge-Coupled Devices (skipper-CCDs) are pixelated silicon detectors with deep sub-electron resolution. Their radiation hardness and capability to reconstruct energy deposits with unprecedented precision make them a promising technology for space-based X-ray astronomy. In this scenario, optical and near-infrared photons may saturate the sensor, distorting the reconstructed signal. We present a light-tight shield for skipper-CCDs to suppress optical backgrounds while preserving X-ray detection efficiency. We deposited thin aluminum layers on the CCD surface using an e-beam evaporator and evaluated their blinding performance across wavelengths from 650 to 1000 nm using a monochromator, as well as the X-ray transmission using an $^{55}$Fe source. We find that 50 and 100 nm layers provide >99.6% light suppression, with no efficiency loss for 5.9 and 6.4 keV X-rays. In addition, we used Geant4 simulations to extend these results to a broader energy range and quantify the efficiency loss for different aluminum thicknesses. Results show that thin aluminum coatings are an effective, low-cost solution for optical suppression in skipper-CCDs intended for X-ray detection and space instrumentation.

astro-ph.IM

Searches for CEνNS and Physics beyond the Standard Model using Skipper-CCDs at CONNIE

The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) aims to detect the coherent scattering (CE$ν$NS) of reactor antineutrinos off silicon nuclei using thick fully-depleted high-resistivity silicon CCDs. Two Skipper-CCD sensors with sub-electron readout noise capability were installed at the experiment next to the Angra-2 reactor in 2021, making CONNIE the first experiment to employ Skipper-CCDs for reactor neutrino detection. We report on the performance of the Skipper-CCDs, the new data processing and data quality selection techniques and the event selection for CE$ν$NS interactions, which enable CONNIE to reach a record low detection threshold of 15 eV. The data were collected over 300 days in 2021-2022 and correspond to exposures of 14.9 g-days with the reactor-on and 3.5 g-days with the reactor-off. The difference between the reactor-on and off event rates shows no excess and yields upper limits at 95% confidence level for the neutrino interaction rates comparable with previous CONNIE limits from standard CCDs and higher exposures. Searches for new neutrino interactions beyond the Standard Model were performed, yielding an improvement on the previous CONNIE limit on a simplified model with light vector mediators. A first dark matter (DM) search by diurnal modulation was performed by CONNIE and the results represent the best limits on the DM-electron scattering cross-section, obtained by a surface-level experiment. These promising results, obtained using a very small-mass sensor, illustrate the potential of Skipper-CCDs to probe rare neutrino interactions and motivate the plans to increase the detector mass in the near future.

hep-ex

XCOM: Full Mesh Network Synchronization and Low-Latency Communication for QICK (Quantum Instrumentation Control Kit)

Quantum computing experiments and testbeds with large qubit counts have until recently been a privilege afforded only to large companies or quantum technologies where scaling to hundreds or thousands of qubits does not require a substantial increase in quantum control hardware (neutral atoms, trapped ions, or spin defects). Superconducting and spin qubit testbeds critically depend on scaling their control systems beyond what a single electronics board can provide. Multi-board control systems combining RF, fast DC control, bias, and readout require precise synchronization and communication across many hardware and firmware components. To address this, we present XCOM, a network that synchronizes QICK boards and the absolute clocks governing quantum program execution to within 100 ps, free of drift and loss of lock. XCOM also provides deterministic, all-to-all simultaneous data communication with latency below 185 ns. Like QICK itself, XCOM is compatible with a broad range of qubit technologies and is designed to scale to large systems.

quant-ph

SQuaD: Smart Quantum Detection for Photon Recognition and Dark Count Elimination

Quantum detectors of single photons are an essential component for quantum information processing across computing, communication and networking. Today's quantum detection system, which consists of single photon detectors, timing electronics, control and data processing software, is primarily used for counting the number of single photon detection events. However, it is largely incapable of extracting other rich physical characteristics of the detected photons, such as their wavelengths, polarization states, photon numbers, or temporal waveforms. This work, for the first time, demonstrates a smart quantum detection system, SQuaD, which integrates a field programmable gate array (FPGA) with a neural network model, and is designed to recognize the features of photons and to eliminate detector dark-count. The SQuaD is a fully integrated quantum system with high timing-resolution data acquisition, onboard multi-scale data analysis, intelligent feature recognition and extraction, and feedback-driven system control. Our \name experimentally demonstrates 1) reliable photon counting on par with the state-of-the art commercial systems; 2) high-throughput data processing for each individual detection events; 3) efficient dark count recognition and elimination; 4) up to 100\% accurate feature recognition of photon wavelength and polarization. Additionally, we deploy the SQuaD to an atomic (erbium ion) photon emitter source to realize noise-free control and readout of a spin qubit in the telecom band, enabling critical advances in quantum networks and distributed quantum information processing.

quant-ph

PhotonIDs: ML-Powered Photon Identification System for Dark Count Elimination

Reliable single photon detection is the foundation for practical quantum communication and networking. However, today's superconducting nanowire single photon detector(SNSPD) inherently fails to distinguish between genuine photon events and dark counts, leading to degraded fidelity in long-distance quantum communication. In this work, we introduce PhotonIDs, a machine learning-powered photon identification system that is the first end-to-end solution for real-time discrimination between photons and dark count based on full SNSPD readout signal waveform analysis. PhotonIDs ~demonstrates: 1) an FPGA-based high-speed data acquisition platform that selectively captures the full waveform of signal only while filtering out the background data in real time; 2) an efficient signal preprocessing pipeline, and a novel pseudo-position metric that is derived from the physical temporal-spatial features of each detected event; 3) a hybrid machine learning model with near 98% accuracy achieved on photon/dark count classification. Additionally, proposed PhotonIDs ~ is evaluated on the dark count elimination performance with two real-world case studies: (1) 20 km quantum link, and (2) Erbium ion-based photon emission system. Our result demonstrates that PhotonIDs ~could improve more than 31.2 times of signal-noise-ratio~(SNR) on dark count elimination. PhotonIDs ~ marks a step forward in noise-resilient quantum communication infrastructure.

quant-ph

Charge Trap Analysis in a SENSEI Skipper-CCD: Understanding Low-Energy Backgrounds in Rare-Event Searches

Skipper Charge-Coupled Devices (Skipper-CCDs) are ultra-low-threshold detectors capable of detecting energy deposits in silicon at the eV scale. Increasingly used in rare-event searches, one of the major challenges in these experiments is mitigating low-energy backgrounds. In this work, we present results on trap characterization in a silicon Skipper-CCD produced in the same fabrication run as the SENSEI experiment at SNOLAB. Lattice defects contribute to backgrounds in rare-event searches through single-electron charge trapping. To investigate this, we employ the charge-pumping technique at different temperatures to identify dipoles produced by traps in the CCD channel. We fully characterize a fraction of these traps and use this information to extrapolate their contribution to the single-electron background in SENSEI. We find that this subpopulation of traps does not contribute significantly but more work is needed to assess the impact of the traps that can not be characterized.

hep-ex

SENSEI: A Search for Diurnal Modulation in sub-GeV Dark Matter Scattering

Dark matter particles with sufficiently large interactions with ordinary matter can scatter in the Earth's atmosphere and crust before reaching an underground detector. This Earth-shielding effect can induce a directional dependence in the dark matter flux, leading to a sidereal daily modulation in the signal rate. We perform a search for such a modulation using data from the SENSEI experiment, targeting MeV-scale dark matter. We achieve an order-of-magnitude improvement in sensitivity over previous direct-detection bounds for dark-matter masses below 1 MeV, assuming the Standard Halo Model with a Maxwell--Boltzmann velocity distribution, and constrain the amplitude of a general daily modulation signal to be below 6.8 electrons per gram per day.

hep-ex

DarkNESS: A skipper-CCD NanoSatellite for Dark Matter Searches

The Dark matter Nanosatellite Equipped with Skipper Sensors (DarkNESS) deploys a recently developed skipper-CCD architecture with sub-electron readout noise in low Earth orbit (LEO) to investigate potential signatures of dark matter (DM). The mission addresses two interaction channels: electron recoils from strongly interacting sub-GeV DM and X-rays produced through decaying DM. Orbital observations avoid attenuation that limits ground-based measurements, extending sensitivity reach for both channels. The mission proceeds toward launch following laboratory validation of the instrument. A launch opportunity has been secured through Firefly Aerospace's DREAM 2.0 program, awarded to the University of Illinois Urbana-Champaign (UIUC). This will constitute the first use of skipper-CCDs in space and evaluate their suitability for low-noise X-ray and single-photon detection in future space observatories.

astro-ph.IM

Readout Optimization of Multi-Amplifier Sensing Charge-Coupled Devices for Single-Quantum Measurement

The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise reduction is achieved by taking multiple measurements of the charge in each pixel. These multiple measurements come at the cost of extra readout time, which has been a limitation for the broader adoption of this technology in particle physics, quantum imaging, and astronomy applications. This work presents recent results of a novel sensor architecture that uses multiple non-destructive floating-gate amplifiers in series to achieve sub-electron readout noise in a thick, fully-depleted silicon detector to overcome the readout time overhead of the Skipper-CCD. This sensor is called the Multiple-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier, and the measurements from multiple amplifiers can be combined to further reduce the readout noise. We will show results obtained for sensors with 8 and 16 amplifiers per readout stage in new readout operations modes to optimize its readout speed. The noise reduction capability of the new techniques will be demonstrated in terms of its ability to reduce the noise by combining the information from the different amplifiers, and to resolve signals in the order of a single photon per pixel. The first readout operation explored here avoids the extra readout time needed in the MAS-CCD to read a line of the sensor associated with the extra extent of the serial register. The second technique explore the capability of the MAS-CCD device to perform a region of interest readout increasing the number of multiple samples per amplifier in a targeted region of the active area of the device.

astro-ph.IM

SENSEI: First Direct-Detection Results on sub-GeV Dark Matter from SENSEI at SNOLAB

We present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. We employ a bias-mitigation technique of hiding approximately 46% of our total data and aggressively mask images to remove backgrounds. Given a total exposure after masking of 100.72 gram-days from well-performing sensors, we observe 55 two-electron events, 4 three-electron events, and no events containing 4 to 10 electrons. The two-electron events are consistent with pileup from one-electron events. Among the 4 three-electron events, 2 appear in pixels that are likely impacted by detector defects, although not strongly enough to trigger our "hot-pixel" mask. We use these data to set world-leading constraints on sub-GeV dark matter interacting with electrons and nuclei.

astro-ph.CO

DarkNESS: developing a skipper-CCD instrument to search for Dark Matter from Low Earth Orbit

The DarkNESS (Dark Matter Nano-satellite Equipped with Skipper Sensors) mission aims to deploy a skipper-CCD CubeSat Observatory to search for dark matter (DM) from Low Earth Orbit. This mission will employ novel skipper-CCDs to investigate O(keV) X-rays from decaying DM, as well as electron recoils from strongly-interacting sub-GeV DM. The DarkNESS mission will be the first space deployment of skipper-CCDs, and the DarkNESS team is developing a skipper-CCD instrument that is compatible with the CubeSat platform. DarkNESS has recently progressed from laboratory validation to a Critical Design Review (CDR) phase, with a launch opportunity anticipated in late 2025. The implementation of the DarkNESS skipper-CCD payload on the CubeSat platform will pave the way for future demonstrators of space-based imagers for X-ray and single-electron counting applications.

astro-ph.IM

SENSEI at SNOLAB: Single-Electron Event Rate and Implications for Dark Matter

We present results from data acquired by the SENSEI experiment at SNOLAB after a major upgrade in May 2023, which includes deploying 16 new sensors and replacing the copper trays that house the CCDs with a new light-tight design. We observe a single-electron event rate of $(1.39 \pm 0.11) \times 10^{-5}$ e$^-$/pix/day, corresponding to $(39.8 \pm 3.1)$ e$^-$/gram/day. This is an order-of-magnitude improvement compared to the previous lowest single-electron rate in a silicon detector and the lowest for any photon detector in the near-infrared-ultraviolet range. We use these data to obtain a 90% confidence level upper bound of $1.53 \times 10^{-5}$ e$^-$/pix/day and to set constraints on sub-GeV dark matter candidates that produce single-electron events. We hypothesize that the data taken at SNOLAB in the previous run, with an older tray design for the sensors, contained a larger rate of single-electron events due to light leaks. We test this hypothesis using data from the SENSEI detector located in the MINOS cavern at Fermilab.

astro-ph.CO

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k x 1k, 15 $μ$m pixel, fully-depleted, p-channel devices that have been thinned to ~250 $μ$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., single-sample readout noise < 4.3 e- rms/pixel, the ability to achieve multi-sample readout noise $\ll$ 1 e- rms/pixel, full-well capacities ~40,000-65,000 e-, low dark current and charge transfer inefficiency (~2 x 10$^{-4}$ e-/pixel/s and 3.44 x 10$^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim$ 80% between 450 nm and 980 nm ($\gtrsim$ 90% between 600 nm and 900 nm). We optimized the readout sequence timing to achieve sub-electron noise (~0.5 e- rms/pixel) in a region of 2k x 4k pixels and photon-counting noise (~0.22 e- rms/pixel) in a region of 220 x 4k pixels, each with a readout time of $\lesssim$ 17 min. We observed two quasars (HB89 1159+123 and QSO J1621-0042) at redshift z ~ 3.5, two high-redshift galaxy clusters (CL J1001+0220 and SPT-CL J2040-4451), an emission line galaxy at z = 0.3239, a candidate member star of the Boötes II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observations of the quasar HB89 1159+123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvements for SIFS observations in the low-background, readout-noise-dominated regime. We outline scientific studies that will leverage the SIFS-Skipper CCD data and new detector architectures that utilize the Skipper floating gate amplifier with faster readout times.

astro-ph.IM

Dual-sided Charge-Coupled Devices

Existing Charge-Coupled Devices (CCDs) operate by detecting either the electrons or holes created in an ionization event. We propose a new type of imager, the Dual-Sided CCD, which collects and measures both charge carriers on opposite sides of the device via a novel dual-buried channel architecture. We show that this dual detection strategy provides exceptional dark-count rejection and enhanced timing capabilities. These advancements have wide-ranging implications for dark-matter searches, near-IR/optical spectroscopy, and time-domain X-ray astrophysics.

physics.ins-det

Skipper-CCD Sensors for the Oscura Experiment: Requirements and Preliminary Tests

Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2-10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru. In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.

physics.ins-det

Searching for millicharged particles with 1 kg of Skipper-CCDs using the NuMI beam at Fermilab

Oscura is a planned light-dark matter search experiment using Skipper-CCDs with a total active mass of 10 kg. As part of the detector development, the collaboration plans to build the Oscura Integration Test (OIT), an engineering test with 10% of the total mass. Here we discuss the early science opportunities with the OIT to search for millicharged particles (mCPs) using the NuMI beam at Fermilab. mCPs would be produced at low energies through photon-mediated processes from decays of scalar, pseudoscalar, and vector mesons, or direct Drell-Yan productions. Estimates show that the OIT would be a world-leading probe for mCPs in the MeV mass range.

hep-ex

Experimental advances with the QICK (Quantum Instrumentation Control Kit) for superconducting quantum hardware

The QICK is a standalone open source qubit controller that was first introduced in 2022. In this follow-up work, we present recent experimental use cases that the QICK uniquely enabled for superconducting qubit systems. These include multiplexed signal generation and readout, mixer-free readout, pre-distorted fast flux pulses, and phase-coherent pulses for parametric operations, including high-fidelity parametric entangling gates. We explain in detail how the QICK was used to enable these experiments.

quant-ph