SearcharxivSearch

arXiv subjects

Shota Okada

Publications and source records attributed to Shota Okada.

4 recordsLinked to original sources

Wireless data transmission in a 560-GHz band using low-phase-noise terahertz wave generated by photomixing of a pair of distributed feedback lasers injection-locking to Kerr micro-resonator soliton comb

The demand for higher data rates in next-generation mobile wireless communication systems (6G) has led to significant interest in terahertz (THz) waves as a high-frequency, broad modulation bandwidth carrier wave. In this study, we propose and demonstrate a wireless data transfer in the 560-GHz band using low-phase-noise THz waves generated by photomixing of a pair of distributed feedback lasers injection-locking to Kerr micro-resonator soliton comb. Experimental results showed near-error-free on-off keying (OOK) data transfer at 1 Gbit/s in the 560-GHz band, with a Q-factor of 6.23, surpassing the error-free limit. Also, modulation formats of binary phase shift keying (BPSK) and quadrature phase shift keying (QPSK) were successfully used, showing clear constellation diagrams and relatively low root mean squared error vector magnitude (rms EVM) values of 23.9% and 23.6%, respectively. Moreover, data transfer at 0.4 Gbit/s in 16 quadrature amplitude modulation (16QAM) demonstrated clear isolated symbols and achieved a low rms EVM value of 8.1%, complying with the IEEE 802.15.3d standard amendment. These demonstrations highlight the potential of using injection-locked DFB lasers with the Kerr micro-resonator soliton comb to achieve high-quality, high-speed wireless data transfer in the 560-GHz band. These findings contribute significantly to the advancement of wireless communication technology in the THz frequency range and pave the way for the realization of 6G wireless communication systems.

physics.optics

Terahertz wireless communication at 560-GHz band using Kerr micro-resonator soliton comb

Terahertz (THz) waves have attracted attention as carrier waves for next-generation wireless communications (6G). Electronic THz emitters are widely used in current mobile communications; however, they may face technical limitations in 6G with upper-frequency limits. We demonstrate wireless communication in a 560-GHz band by using a photonic THz emitter based on photomixing of a 560-GHz-spacing soliton microcomb in a uni-travelling carrier photodiode together with a THz receiver of Schottky barrier diode. The on-off keying data transfer with 2-Gbit/s achieves a Q-factor of 3.4, thus, satisfying the limit of forward error correction.

physics.optics

Low phase noise THz generation from a fiber-referenced Kerr microresonator soliton comb

THz oscillators generated via frequency-multiplication of microwaves are facing difficulty in achieving low phase noise. Photonics-based techniques, in which optical two tones are translated to a THz wave through opto-electronic conversion, are promising if the relative phase noise between the two tones is well suppressed. Here, a THz ($\approx$ 560 GHz) wave with a low phase noise is provided by a frequency-stabilized, dissipative Kerr microresonator soliton comb. The repetition frequency of the comb is stabilized to a long fiber in a two-wavelength delayed self-heterodyne interferometer, significantly reducing the phase noise of the THz wave. A measurement technique to characterize the phase noise of the THz wave beyond the limit of a frequency-multiplied microwave is also demonstrated, showing the superior phase noise of the THz wave to any other photonic THz oscillators (> 300 GHz).

physics.optics

Rapid, high-sensitivity detection of biomolecules using dual-comb biosensing: application to the SARS-CoV-2 nucleocapsid protein

Rapid, sensitive detection of biomolecules is important for improved testing methods for viruses as well as biomarkers and environmental hormones. For example, testing for SARS-CoV-2 is essential in the fight against the COVID-19 pandemic. Reverse-transcription polymerase chain reaction (RT-PCR) is the current standard for COVID-19 testing; however, it is hampered by the long testing process. Shortening the testing process while achieving high sensitivity would facilitate sooner quarantine and thus presumably prevention of the spread of SARS-CoV-2. Here, we aim to achieve rapid, sensitive detection of the SARS-CoV-2 nucleocapsid protein by enhancing the performance of optical biosensing with a dual-comb configuration of optical frequency combs. The virus-concentration-dependent optical spectrum shift is transformed into a photonic RF shift by frequency conversion between the optical and RF regions, facilitating mature electrical frequency measurements. Furthermore, active-dummy temperature-drift compensation enables very small changes in the virus-concentration-dependent signal to be extracted from the large, variable background signal. This dual-comb biosensing technique has the potential to reduce the COVID-19 testing time to 10 min while maintaining sensitivity close to that of RT-PCR. Furthermore, this system can be applied for sensing of not only viruses but also various biomolecules for clinical diagnosis, health care, and environmental monitoring.

q-bio.QM