Searcharxiv⌕ Search

arXiv subjects

Shreyas Sen

Publications and source records attributed to Shreyas Sen.

At least 19 recordsLinked to original sources

HDR-DTCP: High-Dynamic-Range Differential Tissue-Coupled Wireless Powering for Tunable Biphasic Stimulation in Injectable Implants

Next-generation implantable neurostimulators require efficient wireless power delivery in smaller, less invasive form factors, yet variations in tissue coupling, implantation conditions, and stimulation loads can alter received power (or requirements) and degrade energy-harvesting performance. This work presents high-dynamic-range (HDR) differential tissue-coupled powering (DTCP), termed HDR-DTCP, a body-coupled architecture in which noninvasive differential electrodes establish an AC electric field in tissue and a thread-like implant extracts power from the longitudinal potential gradient for on-chip harvesting and stimulation. Distributed coupling along the implant length, rather than receiver cross-section, enables minimally invasive injectable geometries, with harvested power scaling with implant length. A 65-nm complementary metal-oxide-semiconductor (CMOS) prototype integrates a reconfigurable four-stage energy harvester with automatic stage selection and a tunable constant-current biphasic stimulator, achieving 63.5\% peak power-conversion efficiency (PCE) at $-16.3$ dBm and $>50\%$ PCE over a 9-dB input-power range. Preliminary in-vivo validation of DTCP was done with a second application-specific integrated circuit (ASIC) on an injectable flexible substrate, capable of being delivered through a 14-gauge needle adjacent to the sciatic nerve of Sprague-Dawley rats (n=4). External copper-pad DTCP powering evoked repeatable hind-limb twitches and electromyography (EMG) response; ultrasound confirmed sub-millimeter nerve proximity, video-based paw-tip tracking captured the response, and 8-day post-implant dissection verified placement along the sciatic-nerve trajectory. Overall, this work provides an integrated wireless powering, energy-harvesting, and stimulation platform toward fully battery-free injectable neuromodulation implants.

eess.SP↗

Design-Space Exploration of Distributed Neural Networks in Low-Power Wearable Nodes

Wearable devices increasingly support intelligent applications such as augmented reality, continuous health monitoring, and vision-based interaction. However, the neural networks (NNs) required by these applications often exceed the memory and energy budgets of wearable nodes. Cloud offloading reduces local computation but increases communication demand and can introduce latency and privacy concerns. TinyML reduces model complexity, potentially sacrificing accuracy without resolving the memory demands of vision workloads. This paper presents DistNN, a hardware-software framework for distributed NN inference that partitions execution between an ultra-low-power (ULP) wearable node and a nearby resource-rich hub, such as a smartphone. The node processes early NN layers and sends intermediate feature maps to the hub, which executes the remaining layers. To choose the split point, we propose a platform-independent figure of merit (FoM) based on data volume (DV) and cumulative computation cost (CC). The FoM captures the central trade-off: earlier splits reduce node computation but increase communication, whereas later splits reduce transmitted data but increase node computation. We also derive conditions for a net node-side energy benefit from distribution and demonstrate that the target autoencoder (AE) workloads cannot run monolithically on representative wearable microcontrollers. To enable ULP execution, we synthesize a custom node using low-precision fixed-point arithmetic. Post-synthesis estimates place DistNN below the 10 mW node-power target, with average node-compute power approximately 11x lower than that of the recent ML ASIC baselines evaluated. Across convolutional NNs and AEs, DistNN preserves task quality, achieving a structural similarity index (SSIM) of approximately 0.90 for image reconstruction with low-precision node features and a resource-rich hub decoder.

cs.ET↗

BRIDGE-EEG: Bridging Self-Supervised Pretraining and Efficient Deployment for Cross-Dataset EEG Classification

The growing use of electroencephalography (EEG) motivates automated analysis that is accurate, transferable, and deployable on constrained hardware. Recent EEG foundation models learn general representations from large-scale pretraining, but their size and computational cost limit edge and wearable deployment. We introduce BRIDGE-EEG, an efficient multi-task EEG classification pipeline that preserves the benefits of pretraining while reducing model size. A unified preprocessing scheme maps heterogeneous recordings with different channel counts, montages, and sampling rates to a device-agnostic 62-channel time--frequency representation. We pretrain an SE-ResNet18 teacher (11.84 M parameters) with SimCLR on unlabeled EEG from five heterogeneous datasets, then compress it into SE-ResNet8 (1.56 M) and SE-ResNet4 (0.48 M) students using task-agnostic and task-specific distillation. We evaluate six benchmarks spanning abnormality detection, motor imagery, and emotion recognition. For abnormality detection and emotion recognition, the students achieve accuracy comparable to or better than several recent EEG foundation models with 10--1,000$\times$ more parameters. Motor imagery shows a remaining representation gap, highlighting the importance of pretraining diversity. Inference profiling on a server GPU, desktop CPU, and NVIDIA Jetson Orin Nano shows up to 3.0$\times$ lower edge energy per inference (15.64 mJ vs. 46.67 mJ). The compact models further support future deployment on MCU-class wearables.

cs.HC↗

Bidirectional Wireless Communication for Weakly Coupled Implantable Brain-Computer Interfaces

Implantable brain-computer interfaces (BCIs) promise transformative societal impact, from restoring lost motor, sensory, and speech function in patients with paralysis, stroke, sclerosis, and sensory deficits to serving as a high-bandwidth conduit between human cognition and machine intelligence. Realizing these visions requires moving from laboratory prototypes to chronic clinical systems that support thousands to millions of electrodes, several millimeters to centimeters deep beneath the brain surface, under strict heating and size limits. Almost every clinically relevant implant therefore operates in a weakly coupled regime, with coupling coefficients of $10^{-3}$ to $10^{-1}$ across centimetres of lossy tissue. In this regime, the wireless channel sets the limits of power-transfer efficiency, communication bandwidth, and energy per bit. We review the recent progress of bidirectional wireless links across inductive, mid-field, RF, ultrasonic, magnetoelectric, optical, UWB, and electro-quasistatic modalities, and benchmark them against the clinical axes of depth, size, and data rate. Within an approximately 10 mW communication budget set by the approximately $1^\circ$C tissue-heating ceiling, narrowband high-Q links are well suited for power transfer and low-speed data, but at 1-10 nJ/b cannot reach the greater than 10 Mbps to tens of Gbps uplinks that thousand- to million-channel interfaces demand, even with aggressive on-implant compression. This calls for sub-10 pJ/b and ultimately sub-1 pJ/b wireless links, where wideband techniques, such as ultra-wideband (UWB) and brain-channel communication (BCC), are suitable. We close with a quantitative framework for analyzing such wireless links and a co-design roadmap across electromagnetics, circuits, packaging, security, and regulation, toward secure, networked, million-channel brain interfaces.

eess.SY↗

From Muscle to Text with MyoText: sEMG to Text via Finger Classification and Transformer-Based Decoding

Surface electromyography (sEMG) provides a direct neural interface for decoding muscle activity and offers a promising foundation for keyboard-free text input in wearable and mixed-reality systems. Previous sEMG-to-text studies mainly focused on recognizing letters directly from sEMG signals, forming an important first step toward translating muscle activity into text. Building on this foundation, we present MyoText, a hierarchical framework that decodes sEMG signals to text through physiologically grounded intermediate stages. MyoText first classifies finger activations from multichannel sEMG using a CNN-BiLSTM-Attention model, applies ergonomic typing priors to infer letters, and reconstructs full sentences with a fine-tuned T5 transformer. This modular design mirrors the natural hierarchy of typing, linking muscle intent to language output and reducing the search space for decoding. Evaluated on 30 users from the emg2qwerty dataset, MyoText outperforms baselines by achieving 85.4% finger-classification accuracy, 5.4% character error rate (CER), and 6.5% word error rate (WER). Beyond accuracy gains, this methodology establishes a principled pathway from neuromuscular signals to text, providing a blueprint for virtual and augmented-reality typing interfaces that operate entirely without physical keyboards. By integrating ergonomic structure with transformer-based linguistic reasoning, MyoText advances the feasibility of seamless, wearable neural input for future ubiquitous computing environments.

cs.LG↗

From the Two-Capacitor Paradox to Electromagnetic Side-Channel Mitigation in Digital Circuits

The classical two-capacitor paradox of the lost energy is revisited from an electronic circuit security stand-point. The paradox has been solved previously by various researchers, and the energy lost during the charging of capacitors has been primarily attributed to the heat and radiation. We analytically prove this for various standard resistor-capacitor (RC) and resistor-inductor-capacitor (RLC) circuit models. From the perspective of electronic system security, electromagnetic (EM) side-channel analysis (SCA) has recently gained significant prominence with the growth of resource-constrained, internet connected devices. This article connects the energy lost due to capacitor charging to the EM SCA leakage in electronic devices, leading to the recovery of the secret encryption key embedded within the device. Finally, with an understanding of how lost energy relates to EM radiation, we propose adiabatic charging as a solution to minimize EM leakage, thereby paving the way towards low-overhead EM SCA resilience.

cs.CR↗

Near Field Electric (NFE): Energy-efficient, High-speed Communication at Decimeter-range

Near-field technologies enable contactless payments, building access, automotive keyless entry, and supply chain tracking. Existing approaches face fundamental trade-offs: magnetic-based methods (NFC/NFMI) achieve low power but are limited to sub-megabit rates, while millimeter-wave techniques provide gigabits/sec connectivity at higher power consumption and only centimeter-scale ranges. We demonstrate that near-field electric (NFE) communication breaks this trade-off via capacitive coupling enabled by confined electric fields. NFE simultaneously achieves ultra-low power ($<$1 mW per transceiver), high-speed data throughput ($>$3 Mbps), and configurable decimeter-range (5-30 cm) capabilities previously considered mutually exclusive. Systematic measurements across multiple orientations and configurations show NFE can support decimeter communication coverage. The power consumption of 0.4 mW at the transmitter (Tx) and 0.6 mW at the receiver (Rx), when combined is up to $\sim$24$\times$ lower than NFC and $\sim$3$\times$ lower than NFMI while achieving significantly higher data rates, and a couple of orders of magnitude lower power than mm-wave based technique. Testing with symmetrical electrodes across eight orientations validated consistent performance and robustness for practical deployments. Extended-range experiments achieved stable 2 Mbps throughput at 3.5 meters using conductive media, demonstrating NFE's unique ability to leverage environmental conductors. Optimized device design can facilitate achieving an extended range for Body-assisted NFE up to 1 m. Results establish NFE as foundational for next-generation wireless applications where security, low power, and throughput converge, enabling dense IoT deployments, secure payment systems, and high-speed device-to-device communication previously limited by the power-performance trade-off.

eess.SP↗

Improving deep neural network performance through sampling

Energy efficient sampling with probabilistic neurons or p-bits has been demonstrated in the context of Boltzmann machines and it is natural to ask if these approaches can be extended to the field of generative AI where energy costs have become prohibitively large. However, this very active field is dominated by feedforward deep neural networks (DNNs) which primarily use multi-bit deterministic neurons with no role for sampling. In this paper we first show that it is feasible to obtain superior accuracy through the use of multiple samples generated by probabilistic networks. This possibility raises the question of which option is energetically preferable for improving accuracy: generating more samples, or adding more bits to a single deterministic sample. We provide a simple expression that can be used to estimate these energy tradeoffs and illustrate it with results for different algorithms and architectures.

cond-mat.dis-nn↗

SSL-SE-EEG: A Framework for Robust Learning from Unlabeled EEG Data with Self-Supervised Learning and Squeeze-Excitation Networks

Electroencephalography (EEG) plays a crucial role in brain-computer interfaces (BCIs) and neurological diagnostics, but its real-world deployment faces challenges due to noise artifacts, missing data, and high annotation costs. We introduce SSL-SE-EEG, a framework that integrates Self-Supervised Learning (SSL) with Squeeze-and-Excitation Networks (SE-Nets) to enhance feature extraction, improve noise robustness, and reduce reliance on labeled data. Unlike conventional EEG processing techniques, SSL-SE-EEG} transforms EEG signals into structured 2D image representations, suitable for deep learning. Experimental validation on MindBigData, TUH-AB, SEED-IV and BCI-IV datasets demonstrates state-of-the-art accuracy (91% in MindBigData, 85% in TUH-AB), making it well-suited for real-time BCI applications. By enabling low-power, scalable EEG processing, SSL-SE-EEG presents a promising solution for biomedical signal analysis, neural engineering, and next-generation BCIs.

eess.SP↗

Effect of nearby Metals on Electro-Quasistatic Human Body Communication

In recent decades Human Body Communication has emerged as a promising alternative to traditional radio wave communication, utilizing the body's conductive properties for low-power connectivity among wearables. This method harnesses the human body as an energy-efficient channel for data transmission within the electro-quasistatic frequency range, enabling advancements in human-machine interaction. While prior work has noted the role of parasitic return paths in such capacitively coupled systems, the influence of surrounding metallic objects on these paths, which are critical for EQS wireless signaling, has not been fully explored. This paper fills that gap with a structured study of how various conducting objects, from non-grounded (floating) metals and grounded metals to enclosed metallic environments such as elevators and cars, affect the body-communication channel. We present a theoretical framework supported by finite element method simulations and experiments with wearable devices. Results show that metallic objects within 20 cm of devices can reduce transmission loss by about 10 dB. When a device ground connects to a grounded metallic object, channel gain can increase by at least 20 dB. Contact area during touch-based interactions with grounded metals produces contact-impedance dependent high-pass channel characteristics. Proximity to metallic objects introduces variability within a critical distance, with grounded metals producing a larger overall effect than floating metals. These findings improve understanding of body-centric communication links and inform design for healthcare, consumer electronics, defense, and industrial applications.

eess.SP↗

Keystroke Detection by Exploiting Unintended RF Emission from Repaired USB Keyboards

Electronic devices and cables inadvertently emit RF emissions as a byproduct of signal processing and/or transmission. Labeled as electromagnetic emanations, they form an EM side-channel for data leakage. Previously, it was believed that such leakage could be contained within a facility since they are weak signals with a short transmission range. However, in the preliminary version of this work [1], we found that the traditional cable repairing process forms a tiny monopole antenna that helps emanations transmit over a long range. Experimentation with three types of cables revealed that emanations from repaired cables remain detectable even at >4 m and can penetrate a 14 cm thick concrete wall. In this extended version, we show that such emanation can be exploited at a long distance for information extraction by detecting keystrokes typed on a repaired USB keyboard. By collecting data for 70 different keystrokes at different distances from the target in 3 diverse environments (open space, a corridor outside an office room, and outside a building) and developing an efficient detection algorithm, ~100% keystroke detection accuracy has been achieved up to 12 m distance, which is the highest reported accuracy at such a long range for USB keyboards in the literature. The effect of two experimental factors, interference and human-body coupling, has been investigated thoroughly. Along with exploring the vulnerability, multi-layer external metal shielding during the repairing process as a possible remedy has been explored. This work exposes a new attack surface caused by hardware modification, its exploitation, and potential countermeasures.

cs.CR↗

Predicting and Understanding College Student Mental Health with Interpretable Machine Learning

Mental health issues among college students have reached critical levels, significantly impacting academic performance and overall wellbeing. Predicting and understanding mental health status among college students is challenging due to three main factors: the necessity for large-scale longitudinal datasets, the prevalence of black-box machine learning models lacking transparency, and the tendency of existing approaches to provide aggregated insights at the population level rather than individualized understanding. To tackle these challenges, this paper presents I-HOPE, the first Interpretable Hierarchical mOdel for Personalized mEntal health prediction. I-HOPE is a two-stage hierarchical model that connects raw behavioral features to mental health status through five defined behavioral categories as interaction labels. We evaluate I-HOPE on the College Experience Study, the longest longitudinal mobile sensing dataset. This dataset spans five years and captures data from both pre-pandemic periods and the COVID-19 pandemic. I-HOPE achieves a prediction accuracy of 91%, significantly surpassing the 60-70% accuracy of baseline methods. In addition, I-HOPE distills complex patterns into interpretable and individualized insights, enabling the future development of tailored interventions and improving mental health support. The code is available at https://github.com/roycmeghna/I-HOPE.

cs.LG↗

A Computational Harmonic Detection Algorithm to Detect Data Leakage through EM Emanation

Unintended electromagnetic emissions, called EM emanations, can be exploited to recover sensitive information, posing security risks. Metal shielding, used by defense organizations to prevent data leakage, is costly and impractical for widespread use. This issue is particularly significant for IoT devices due to their sheer volume and varied deployment environments. Therefore, there is a research need for an automated detection method to monitor facilities and address data leakage promptly. To resolve this challenge, in the preliminary version of this work [1], a CNN-based detection method was proposed using HDMI cable emanations that provided ~95% accuracy up to 22.5 m but had limitations due to training data. In this extended version, we augment the initial study by collecting and characterizing emanation data from IoT devices, everyday electronics, and cables. We propose a harmonic-based emanation detection method by developing a computational harmonic detection algorithm. The proposed method addresses the limitations of the CNN-based method and provides ~100% accuracy not only for HDMI emanation (compared to ~95% in the earlier CNN method) but also for all other tested devices and cables. Finally, it has also been tested in different environments to prove its efficacy in practical scenarios.

cs.CR↗

Writing a Good Security Paper for ISSCC (2025)

Security is increasingly more important in designing chips and systems based on them, and the International Solid-State Circuits Conference (ISSCC), the leading conference for presenting advances in solid-state circuits and semiconductor technology, is committed to hardware security by establishing the security subcommittee since 2024. In the past two years, the authors of this paper reviewed submissions as members of the Security Subcommittee, a part of International Technical Program Committee (ITPC). This paper aims to encourage high-quality submissions to grow this field in the overall scope of the ISSCC.

cs.CR↗

Rudraksh: A compact and lightweight post-quantum key-encapsulation mechanism

Resource-constrained devices such as wireless sensors and Internet of Things (IoT) devices have become ubiquitous in our digital ecosystem. These devices generate and handle a major part of our digital data. However, due to the impending threat of quantum computers on our existing public-key cryptographic schemes and the limited resources available on IoT devices, it is important to design lightweight post-quantum cryptographic (PQC) schemes suitable for these devices. In this work, we explored the design space of learning with error-based PQC schemes to design a lightweight key-encapsulation mechanism (KEM) suitable for resource-constrained devices. We have done a scrupulous and extensive analysis and evaluation of different design elements, such as polynomial size, field modulus structure, reduction algorithm, and secret and error distribution of an LWE-based KEM. Our explorations led to the proposal of a lightweight PQC-KEM, Rudraksh, without compromising security. Our scheme provides security against chosen ciphertext attacks (CCA) with more than 100 bits of Core-SVP post-quantum security and belongs to the NIST-level-I security category (provide security at least as much as AES-128). We have also shown how ASCON can be used for lightweight pseudo-random number generation and hash function in the lattice-based KEMs instead of the widely used Keccak for lightweight design. Our FPGA results show that Rudraksh currently requires the least area among the PQC KEMs of similar security. Our implementation of Rudraksh provides a $\sim3\times$ improvement in terms of the area requirement compared to the state-of-the-art area-optimized implementation of Kyber, can operate at $63\%$-$76\%$ higher frequency with respect to high-throughput Kyber, and improves time-area-product $\sim2\times$ compared to the state-of-the-art compact implementation of Kyber published in HPEC 2022.

cs.CR↗

Body-Resonance Human Body Communication

Seamless interaction between Humans and AI-empowered battery-operated miniaturized electronic devices, exponentially transforming the wearable technology industry while forming an anthropomorphic artificial nervous system for distributed computing around the human body, demands high-speed low-power connectivity. If interconnected via radio frequency (RF) based wireless communication techniques, that being radiative, incur substantial absorption losses from the body during non-line-of-sight scenarios and consume higher power (more than 10s of mW). Although as a promising alternative with its non-radiative nature that resulted in 100X improvement in energy efficiency (sub-10 pJ/bit) and better signal confinement, Electro-Quasistatic Human Body Communication (EQS HBC) incurs moderate path loss (60-70 dB), limited data rate (less than 20 Mbps), making it less suitable for applications demanding fast connectivity like HD audio-video streaming, AR-VR-based products, distributed computing with wearable AI devices. Hence, to meet the requirement of energy-efficient connectivity at 100s of Mbps between wearables, we propose Body-Resonance (BR) HBC, which operates in the near-intermediate field and utilizes the transmission-line-like behavior of the body channel to offer 30X improvement in channel capacity. Our work sheds new light on the wireless communication system for wearables with potential to increase the channel gain by 20 dB with a 10X improvement in bandwidth compared to the EQS HBC for communication over on-body channels (whole-body coverage area). Experimentally demonstrating BR HBC, we presented low-loss (40-50 dB) and wide-band (hundreds of MHz) body channels that are 10X less leaky than radiative wireless communication, hence, can revolutionize the design of wireless communication system for several applications with wearables from healthcare, defense, to consumer electronics.

eess.SP↗

A 0.03${mm}^2$ 100-250MHz Charge-Pump or Amplifier-Less Integrating Sub-Sampling PLL for Ultra-low Power Communication and Computing

Clock generation is an essential part of wireless or wireline communication modules. To facilitate recent advancements in wireline-like communication and in-sensor computing modules at relatively lower data rates, ultra-low power, and accurate clock generation are of the utmost importance. This paper presents a unique implementation of integrating sub-sampling phase locked loop, which alleviates the usage of additional gain elements in the PLL and reduces the noise injection in the system. In this design, the ring oscillator-based PLL can operate a wide frequency range of 100-250MHz while consuming 0.03mm2 of area and 131.8$μW$ of power at 250MHz. The area-normalized figure of merit (FOM) of the integrating SSPLL is found to be -236, while showing a reference spur of -43.2dB.

eess.SP↗

R-STELLAR: A Resilient Synthesizable Signature Attenuation SCA Protection on AES-256 with built-in Attack-on-Countermeasure Detection

Side channel attacks (SCAs) remain a significant threat to the security of cryptographic systems in modern embedded devices. Even mathematically secure cryptographic algorithms, when implemented in hardware, inadvertently leak information through physical side channel signatures such as power consumption, electromagnetic (EM) radiation, light emissions, and acoustic emanations. Exploiting these side channels significantly reduces the search space of the attacker. In recent years, physical countermeasures have significantly increased the minimum traces to disclosure (MTD) to 1 billion. Among them, signature attenuation is the first method to achieve this mark. Signature attenuation often relies on analog techniques, and digital signature attenuation reduces MTD to 20 million, requiring additional methods for high resilience. We focus on improving the digital signature attenuation by an order of magnitude (MTD 200M). Additionally, we explore possible attacks against signature attenuation countermeasure. We introduce a Voltage drop Linear region Biasing (VLB) attack technique that reduces the MTD to over 2000 times less than the previous threshold. This is the first known attack against a physical side-channel attack (SCA) countermeasure. We have implemented an attack detector with a response time of 0.8 milliseconds to detect such attacks, limiting SCA leakage window to sub-ms, which is insufficient for a successful attack.

cs.CR↗