SearcharxivSearch

arXiv subjects

Shuhao Que

Publications and source records attributed to Shuhao Que.

3 recordsLinked to original sources

PM-EKF: A Physiological Model-Based Extended Kalman Filter for Daily-Life Physical Activity Energy Expenditure Estimation

Monitoring physical activity energy expenditure (PAEE) in daily life is essential for characterizing individual health and metabolic status. Although indirect calorimetry provides gold-standard PAEE measurements, it is impractical for continuous daily-life monitoring. Consequently, wearable sensing approaches using inertial measurement units (IMUs) and heart rate (HR) sensors have attracted substantial interest. However, most existing IMU- and HR-based methods are purely data-driven and offer limited physiological interpretability. In this work, we propose a simplified physiological model that explicitly links body movement during activities of daily living to the underlying metabolic gas-exchange processes governing PAEE. The model is formulated as a nonlinear state-space system and embedded within an Extended Kalman Filter (EKF), enabling principled handling of measurement noise, model uncertainty, and system nonlinearities. The proposed framework provides personalized, interpretable PAEE estimates without employing black-box models. Our model was validated using a dataset, including 9 subjects with around 50 minutes of measurements per subject, collected in our lab simulating a free-living condition. Using the respiratory data measured by COSMED K5 as reference and explained variance (R^2) as evaluation metric, our model's predicted PAEE yielded median (min-max) R^2 = 0.72 (0.60--0.87), using three IMUs (pelvis and two thighs) for capturing the body-center-of-mass motion and measured HR for the time-varying cardiac output. Our model outperformed a linear regression (LR) model (R^2 = 0.52 (0.23--0.92)) and CNN-LSTM model (R^2 = 0.65 (0.46--0.78)) on the same dataset. Notably, excluding the sensory HR measurement did not significantly degrade PAEE estimation of all three models, indicating that IMU-captured mechanical workload dominated PAEE estimation performance in our protocol.

eess.SY

Synthetic Data Guided Feature Selection for Robust Activity Recognition in Older Adults

Physical activity during hip fracture rehabilitation is essential for mitigating long-term functional decline in geriatric patients. However, it is rarely quantified in clinical practice. Existing continuous monitoring systems with commercially available wearable activity trackers are typically developed in middle-aged adults and therefore perform unreliably in older adults with slower and more variable gait patterns. This study aimed to develop a robust human activity recognition (HAR) system to improve continuous physical activity recognition in the context of hip fracture rehabilitation. 24 healthy older adults aged over 80 years were included to perform activities of daily living (walking, standing, sitting, lying down, and postural transfers) under simulated free-living conditions for 75 minutes while wearing two accelerometers positioned on the lower back and anterior upper thigh. Model robustness was evaluated using leave-one-subject-out cross-validation. The synthetic data demonstrated potential to improve generalization across participants. The resulting feature intervention model (FIM), aided by synthetic data guidance, achieved reliable activity recognition with mean F1-scores of 0.896 for walking, 0.927 for standing, 0.997 for sitting, 0.937 for lying down, and 0.816 for postural transfers. Compared with a control condition model without synthetic data, the FIM significantly improved the postural transfer detection, i.e., an activity class of high clinical relevance that is often overlooked in existing HAR literature. In conclusion, these preliminary results demonstrate the feasibility of robust activity recognition in older adults. Further validation in hip fracture patient populations is required to assess the clinical utility of the proposed monitoring system.

cs.CV

Accelerometry-based Energy Expenditure Estimation During Activities of Daily Living: A Comparison Among Different Accelerometer Compositions

Physical activity energy expenditure (PAEE) can be measured from breath-by-breath respiratory data, which can serve as a reference. Alternatively, PAEE can be predicted from the body movements, which can be measured and estimated with accelerometers. The body center of mass (COM) acceleration reflects the movements of the whole body and thus serves as a good predictor for PAEE. However, the wrist has also become a popular location due to recent advancements in wrist-worn devices. Therefore, in this work, using the respiratory data measured by COSMED K5 as the reference, we evaluated and compared the performances of COM-based settings and wrist-based settings. The COM-based settings include two different accelerometer compositions, using only the pelvis accelerometer (pelvis-acc) and the pelvis accelerometer with two accelerometers from two thighs (3-acc). The wrist-based settings include using only the left wrist accelerometer (l-wrist-acc) and only the right wrist accelerometer (r-wrist-acc). We implemented two existing PAEE estimation methods on our collected dataset, where 9 participants performed activities of daily living while wearing 5 accelerometers (i.e., pelvis, two thighs, and two wrists). These two methods include a linear regression (LR) model and a CNN-LSTM model. Both models yielded the best results with the COM-based 3-acc setting (LR: $R^2$ = 0.41, CNN-LSTM: $R^2$ = 0.53). No significant difference was found between the 3-acc and pelvis-acc settings (p-value = 0.278). For both models, neither the l-wrist-acc nor the r-wrist-acc settings demonstrated predictive power on PAEE with $R^2$ values close to 0, significantly outperformed by the two COM-based settings (p-values $<$ 0.05). No significant difference was found between the two wrists (p-value = 0.329).

cs.LG