Searcharxiv⌕ Search

arXiv subjects

Shunsuke Daimon

Publications and source records attributed to Shunsuke Daimon.

23 records · Page 2Linked to original sources

Thermographic measurements of the spin Peltier effect in metal/yttrium-iron-garnet junction systems

The spin Peltier effect (SPE), heat-current generation due to spin-current injection, in various metal (Pt, W, and Au single layers and Pt/Cu bilayer)/ferrimagnetic insulator (yttrium iron garnet: YIG) junction systems has been investigated by means of a lock-in thermography (LIT) method. The SPE is excited by a spin current across the metal/YIG interface, which is generated by applying a charge current to the metallic layer via the spin Hall effect. The LIT method enables the thermal imaging of the SPE free from the Joule-heating contribution. Importantly, we observed spin-current-induced temperature modulation not only in the Pt/YIG and W/YIG systems but also in the Au/YIG and Pt/Cu/YIG systems, excluding the possible contamination by anomalous Ettingshausen effects due to proximity-induced ferromagnetism near the metal/YIG interface. As demonstrated in our previous study, the SPE signals are confined only in the vicinity of the metal/YIG interface; we buttress this conclusion by reducing a spatial blur due to thermal diffusion in an infrared emission layer on the sample surface used for the LIT measurements. We also found that the YIG-thickness dependence of the SPE is similar to that of the spin Seebeck effect measured in the same Pt/YIG sample, implying the reciprocal relation between them.

cond-mat.mtrl-sci↗

Concomitant enhancement of longitudinal spin Seebeck effect with thermal conductivity

We report a simultaneous measurement of a longitudinal spin Seebeck effect (LSSE) and thermal conductivity in a Pt/${\rm Y_{3}Fe_{5}O_{12}}$ (YIG)/Pt system in a temperature range from 10 to 300 K. By directly monitoring the temperature difference in the system, we excluded thermal artifacts in the LSSE measurements. It is found that both the LSSE signal and the thermal conductivity of YIG exhibit sharp peaks at the same temperature, differently from previous reports. The maximum LSSE coefficient is found to be $S{\rm_{LSSE}}>10\ μ{\rm V/K}$, one-order-of magnitude greater than the previously reported values. The concomitant enhancement of the LSSE and thermal conductivity of YIG suggests the strong correlation between magnon and phonon transport in the LSSE.

cond-mat.mtrl-sci↗

Thermal imaging of spin Peltier effect

When a charge current is applied to a junction comprising two different conductors, its temperature increases or decreases depending on the direction of the charge current. This phenomenon is called the Peltier effect, which is used in solid-state heat pumps and temperature controllers in electronics. Recently, in spintronics, a spin counterpart of the Peltier effect was observed. The "spin Peltier effect" modulates the temperature of a magnetic junction depending on the direction of a spin current. Here we report thermal imaging of the spin Peltier effect; using active thermography technique, we visualize the temperature modulation induced by a spin current injected into a magnetic insulator from an adjacent metal. The thermal images reveal characteristic distribution of spin-current-induced heat sources, resulting in the temperature change confined only in the vicinity of the metal/insulator interface. The finding of this anomalous temperature distribution allows us to estimate the actual magnitude of the temperature modulation induced by the spin Peltier effect, which is found to be more than one order of magnitude greater than that previously believed.

cond-mat.mes-hall↗

Critical suppression of spin Seebeck effect by magnetic fields

The longitudinal spin Seebeck effect (LSSE) in Pt/Y$_3$Fe$_5$O$_{12}$ (YIG) junction systems has been investigated at various magnetic fields and temperatures. We found that the LSSE voltage in a Pt/YIG-slab system is suppressed by applying high magnetic fields and this suppression is critically enhanced at low temperatures. The field-induced suppression of the LSSE in the Pt/YIG-slab system is too large at around room temperature to be explained simply by considering the effect of the Zeeman gap in magnon excitation. This result requires us to introduce magnon-frequency-dependent mechanism into the scenario of LSSE; low-frequency magnons dominantly contribute to the LSSE. The magnetic field dependence of the LSSE voltage was observed to change by changing the thickness of YIG, suggesting that the thermo-spin conversion by the low-frequency magnons is suppressed in thin YIG films due to the long characteristic lengths of such magnons.

cond-mat.mtrl-sci↗

Sign of inverse spin Hall voltages generated by ferromagnetic resonance and temperature gradients in yttrium iron garnet|platinum bilayers

We carried out a concerted effort to determine the absolute sign of the inverse spin Hall effect voltage generated by spin currents injected into a normal metal. We focus on yttrium iron garnet (YIG)|platinum bilayers at room temperature, generating spin currents by microwaves and temperature gradients. We find consistent results for different samples and measurement setups that agree with theory. We suggest a right-hand-rule to define a positive spin Hall angle corresponding to with the voltage expected for the simple case of scattering of free electrons from repulsive Coulomb charges.

cond-mat.mtrl-sci↗