SearcharxivSearch

arXiv subjects

Shuping Li

Publications and source records attributed to Shuping Li.

3 recordsLinked to original sources

A Rigorous Derivation of the Vlasov-Navier-Stokes Model from Multicomponent Boltzmann Equations

The rigorous justification of the Vlasov-Navier-Stokes system remains an outstanding open problem, both as a mean-field limit of an $N$-particle fluid-interacting system and as a hydrodynamic limit derived from multiphase Boltzmann equations. Inspired by the work of Bernard, Desvillettes, Golse, and Ricci [{\it Commun. Math. Sci.}, {\bf 15}(6), 1703-1741, 2017], we present a rigorous derivation of the incompressible Vlasov-Navier-Stokes system from the two-component Boltzmann system for elastic hard-sphere collisions. To this end, we establish the well-posedness of the rescaled multicomponent Boltzmann system for small initial data. Specifically, we obtain estimates for the solution that hold uniformly with respect to both the thermal speed ratio $\varepsilon$ and the mass ratio $\eta$. Furthermore, under the Vlasov-Navier-Stokes scaling assumption $O(1)\varepsilon^3 \leqslant \eta \leqslant o(1)\varepsilon^2$ as $\varepsilon \rightarrow 0$, we establish the weak convergence of the solution to the fluid-kinetic coupled limit system.

math.AP

DelistBench: Evaluating Search-Enabled LLMs for Auditable Corporate-Event Database Completion

Financial institutions need an independent way to detect missing, stale, and misclassified corporate-event records in vendor databases. We introduce Search-to-Record, a database-assurance task in which search-enabled large language models reconstruct institution-defined event records from public sources for a known security universe and historical cutoff, and DelistBench, a 1,200-record benchmark for security-level delisting announcements. We evaluate five models in paired closed-book and web-enabled conditions. Web access raises announcement-date accuracy within seven days by 34.0 to 48.0 percentage points and event-status accuracy by approximately 2.8 to 21.7 points; the best system achieves 81.5% overall joint accuracy within seven days. Economy web systems achieve 75.9-78.3% overall joint accuracy within seven days at 4.5-6.6% of the API cost of the most expensive web system. Risk-based triage identifies low-error subsets, although the highest-coverage operating point still sends 27.3% of the balanced test set to review. The evaluation identifies web retrieval as the main source of timing gains and shows that low-cost systems can approach the best system's accuracy. Together, Search-to-Record, DelistBench, and the evaluation provide concrete deployment guidance: calibrate triage to local event prevalence and market mix, preserve positive-event recall, and route positive and ambiguous cases to targeted review.

cs.CL

Simultaneous Monitoring of Multiple People's Vital Sign Leveraging a Single Phased-MIMO Radar

Vital sign monitoring plays a critical role in tracking the physiological state of people and enabling various health-related applications (e.g., recommending a change of lifestyle, examining the risk of diseases). Traditional approaches rely on hospitalization or body-attached instruments, which are costly and intrusive. Therefore, researchers have been exploring contact-less vital sign monitoring with radio frequency signals in recent years. Early studies with continuous wave radars/WiFi devices work on detecting vital signs of a single individual, but it still remains challenging to simultaneously monitor vital signs of multiple subjects, especially those who locate in proximity. In this paper, we design and implement a time-division multiplexing (TDM) phased-MIMO radar sensing scheme for high-precision vital sign monitoring of multiple people. Our phased-MIMO radar can steer the mmWave beam towards different directions with a micro-second delay, which enables capturing the vital signs of multiple individuals at the same radial distance to the radar. Furthermore, we develop a TDM-MIMO technique to fully utilize all transmitting antenna (TX)-receiving antenna (RX) pairs, thereby significantly boosting the signal-to-noise ratio. Based on the designed TDM phased-MIMO radar, we develop a system to automatically localize multiple human subjects and estimate their vital signs. Extensive evaluations show that under two-subject scenarios, our system can achieve an error of less than 1 beat per minute (BPM) and 3 BPM for breathing rate (BR) and heartbeat rate (HR) estimations, respectively, at a subject-to-radar distance of $1.6~m$. The minimal subject-to-subject angle separation is $40°$, corresponding to a close distance of $0.5~m$ between two subjects, which outperforms the state-of-the-art.

eess.SP