SearcharxivSearch

arXiv subjects

Shuyi Fan

Publications and source records attributed to Shuyi Fan.

5 recordsLinked to original sources

Difference-in-Differences on a Censored Rating Scale Can Manufacture an Effect: Evidence from a Pre-Registered LLM-Judge Audit

Audits of LLM judges certify a bias by contrasting matched conditions, and the strongest designs difference twice: a within-item contrast between two candidate responses, differenced again across a manipulated attribute, read off a bounded rating scale. We show that this endpoint is not identified on the scale that reports it. Each term of the double difference is censored by its own share, so the observed statistic confounds differential preference with differential attenuation: a severity shift common to both responses manufactures an interaction whenever the two censor it unequally, as unequal distances from the bounds make them, exactly where good stimuli place them. We exhibit the failure inside a pre-registered audit of a frozen pedagogy judge, sealed before the first of its 990 calls. The registered primary endpoint, the effect of a stated learner profile on the judge's scaffolding preference, is null: $+0.085$ points (95\% BCa $[-0.167, +0.353]$, $p = 0.684$). The audit's one nominally significant interaction, $+0.378$ ($p = 0.002$), is not identified as preference: a construction containing zero differential preference reproduces 79 to 85\% of it from the observed severity shift and the scale floor alone. We derive the mechanism in closed form and show that its contribution is measurable from an audit's own ratings.

cs.CL

Rethinking LLM-Judged Helpfulness as a Pedagogy Signal: A Pre-Registered Audit Across Tutor Models

LLM tutoring poses a measurement problem: can a general-purpose helpfulness rubric distinguish direct answer-giving from pedagogical guidance? We audit this signal in a pre-registered study. Within each of three tutor bases, we compare conversational and pedagogical policies instantiated with the same underlying model and paired with one fixed weak simulated student. Deterministic detectors measure answer leakage and next-turn independent work. Claude Opus 4.8 is the frozen, condition-blind primary judge. After the Opus scores were fixed, GPT-5.6 Sol was prospectively specified for a post hoc robustness audit of the same 1,179 confirmatory answer-phase tutor turns under the frozen helpfulness and pedagogy rubrics. On the primary base under Opus, the policies do not differ significantly in helpfulness but are perfectly rank-separated under the pedagogy rubric (Cliff's $|\delta|{=}0.10$ vs. $1.0$). Across the two judges, pedagogy contrasts retain their direction where detected, whereas the helpfulness ordering is judge-contingent, reversing between judges on two of three bases. In an Opus-only ablation, seven primary-base policies span $2.3$ points in mean judged pedagogy within a $0.25$-point band of mean judged helpfulness. Separately, answer-revealing turns are followed by less independent student work on every base, a result that is judge-invariant by construction. In this controlled setting, general-purpose helpfulness is not a reliable pedagogy signal. Tutor evaluation should pair pedagogy-targeted rubrics with deterministic process measures.

cs.CL

Clinical Metadata Guided Limited-Angle CT Image Reconstruction

Limited-angle computed tomography (LACT) offers improved temporal resolution and reduced radiation dose for cardiac imaging, but suffers from severe artifacts due to truncated projections. To address the ill-posedness of LACT reconstruction, we propose a two-stage diffusion framework guided by structured clinical metadata. In the first stage, a transformer-based diffusion model conditioned exclusively on metadata, including acquisition parameters, patient demographics, and diagnostic impressions, generates coarse anatomical priors from noise. The second stage further refines the images by integrating both the coarse prior and metadata to produce high-fidelity results. Physics-based data consistency is enforced at each sampling step in both stages using an Alternating Direction Method of Multipliers module, ensuring alignment with the measured projections. Extensive experiments on both synthetic and real cardiac CT datasets demonstrate that incorporating metadata significantly improves reconstruction fidelity, particularly under severe angular truncation. Compared to existing metadata-free baselines, our method achieves superior performance in SSIM, PSNR, nMI, and PCC. Ablation studies confirm that different types of metadata contribute complementary benefits, particularly diagnostic and demographic priors under limited-angle conditions. These findings highlight the dual role of clinical metadata in improving both reconstruction quality and efficiency, supporting their integration into future metadata-guided medical imaging frameworks.

cs.CV

Large Language Model Evaluated Stand-alone Attention-Assisted Graph Neural Network with Spatial and Structural Information Interaction for Precise Endoscopic Image Segmentation

Accurate endoscopic image segmentation on the polyps is critical for early colorectal cancer detection. However, this task remains challenging due to low contrast with surrounding mucosa, specular highlights, and indistinct boundaries. To address these challenges, we propose FOCUS-Med, which stands for Fusion of spatial and structural graph with attentional context-aware polyp segmentation in endoscopic medical imaging. FOCUS-Med integrates a Dual Graph Convolutional Network (Dual-GCN) module to capture contextual spatial and topological structural dependencies. This graph-based representation enables the model to better distinguish polyps from background tissues by leveraging topological cues and spatial connectivity, which are often obscured in raw image intensities. It enhances the model's ability to preserve boundaries and delineate complex shapes typical of polyps. In addition, a location-fused stand-alone self-attention is employed to strengthen global context integration. To bridge the semantic gap between encoder-decoder layers, we incorporate a trainable weighted fast normalized fusion strategy for efficient multi-scale aggregation. Notably, we are the first to introduce the use of a Large Language Model (LLM) to provide detailed qualitative evaluations of segmentation quality. Extensive experiments on public benchmarks demonstrate that FOCUS-Med achieves state-of-the-art performance across five key metrics, underscoring its effectiveness and clinical potential for AI-assisted colonoscopy.

cs.CV

ResPF: Residual Poisson Flow for Efficient and Physically Consistent Sparse-View CT Reconstruction

Sparse-view computed tomography (CT) is a practical solution to reduce radiation dose, but the resulting ill-posed inverse problem poses significant challenges for accurate image reconstruction. Although deep learning and diffusion-based methods have shown promising results, they often lack physical interpretability or suffer from high computational costs due to iterative sampling starting from random noise. Recent advances in generative modeling, particularly Poisson Flow Generative Models (PFGM), enable high-fidelity image synthesis by modeling the full data distribution. In this work, we propose Residual Poisson Flow (ResPF) Generative Models for efficient and accurate sparse-view CT reconstruction. Based on PFGM++, ResPF integrates conditional guidance from sparse measurements and employs a hijacking strategy to significantly reduce sampling cost by skipping redundant initial steps. However, skipping early stages can degrade reconstruction quality and introduce unrealistic structures. To address this, we embed a data-consistency into each iteration, ensuring fidelity to sparse-view measurements. Yet, PFGM sampling relies on a fixed ordinary differential equation (ODE) trajectory induced by electrostatic fields, which can be disrupted by step-wise data consistency, resulting in unstable or degraded reconstructions. Inspired by ResNet, we introduce a residual fusion module to linearly combine generative outputs with data-consistent reconstructions, effectively preserving trajectory continuity. To the best of our knowledge, this is the first application of Poisson flow models to sparse-view CT. Extensive experiments on synthetic and clinical datasets demonstrate that ResPF achieves superior reconstruction quality, faster inference, and stronger robustness compared to state-of-the-art iterative, learning-based, and diffusion models.

eess.IV