Searcharxiv⌕ Search

arXiv subjects

Shyam Sunder Nishad

Publications and source records attributed to Shyam Sunder Nishad.

2 recordsLinked to original sources

Design optimization and robustness analysis of rigid-link flapping mechanisms

Rigid link flapping mechanisms remain the most practical choice for flapping wing micro-aerial vehicles (MAVs) to carry useful payloads and onboard batteries for free flight due to their long-term durability and reliability. However, MAVs with these mechanisms require significant weight reduction to achieve high agility and maneuverability. One approach involves using single-DOF planar rigid linkages, which are rarely optimized dimensionally for high lift and low power, considering their sweeping kinematics and the unsteady aerodynamic effects. We integrated a mechanism simulator based on a quasistatic nonlinear finite element method with an unsteady vortex lattice method-based aerodynamic analysis tool within an optimization routine. We optimized three different mechanism topologies from the literature. Significant power savings were observed up to 34% in some cases, due to increased amplitude and higher lift coefficients resulting from optimized asymmetric sweeping velocity profiles. We also conducted a robustness analysis to quantify performance sensitivity to manufacturing tolerances. It provided a trade-off between performance and reliability and revealed the need for tight manufacturing tolerances and careful material selection. Finally, the analysis helped select the best mechanism topology, as we observed significant variation in sensitivity to manufacturing tolerances and peak input torque values across different topologies for a given design lift value. The presented unified computational tool can find application in flapping mechanism topology optimization, as it can simulate any generic single-DOF planar rigid linkage without supplying kinematics manually.

cs.RO↗

Comprehending finger flexor tendon pulley system using a computational analysis

Existing prosthetic/orthotic designs are rarely based on kinetostatics of a biological finger, especially its tendon-pulley system (TPS) which helps render a set of extraordinary functionalities. Studies on computational models or cadaver experiments do exist. However, they provide little information on TPS configurations that lead to lower tendon tension, bowstringing, and pulley stresses, all of which a biological finger may be employing after all. A priori knowledge of such configurations and associated trade-offs is helpful not only from the design viewpoint of, say, an exoskeleton but also for surgical reconstruction procedures. We present a parametric study to determine optimal TPS configurations for the flexor mechanism. A compliant, flexure-based computational model is developed and simulated using the pseudo rigid body method, with various combinations of pulley/tendon attachment point locations, pulley heights, and widths. Deductions are drawn from the data collected to recommend the most suitable configuration. Many aspects of the biological TPS configuration are explained through the presented analysis. We reckon that the analytical approach herein will be useful in arriving at customized (optimized) hand exoskeletal designs.

cs.RO↗