SearcharxivSearch

arXiv subjects

Si-Yuan Zhang

Publications and source records attributed to Si-Yuan Zhang.

6 recordsLinked to original sources

Progressively Exploring and Exploiting Inference Data to Break Fine-Grained Classification Barrier

Current fine-grained classification research primarily focuses on fine-grained feature learning. However, in real-world scenarios, fine-grained data annotation is challenging, and the features and semantics are highly diverse and frequently changing. These issues create inherent barriers between traditional experimental settings and real-world applications, limiting the effectiveness of conventional fine-grained classification methods. Although some recent studies have provided potential solutions to these issues, most of them still rely on limited supervised information and thus fail to offer effective solutions. In this paper, based on theoretical analysis, we propose a novel learning paradigm to break the barriers in fine-grained classification. This paradigm enables the model to progressively learn during inference, thereby leveraging cost-free data at inference time to more accurately represent fine-grained categories and adapt to dynamic semantic changes. On this basis, an efficient EXPloring and EXPloiting strategy and method (EXP2) is designed. Thereinto, useful inference data samples are explored according to class representations and exploited to optimize classifiers. Experimental results demonstrate the general effectiveness of our method, providing guidance for future in-depth understanding and exploration of real-world fine-grained classification.

cs.CV

Discrimination of pp solar neutrinos and $^{14}$C double pile-up events in a large-scale LS detector

As a unique probe, precision measurement of \textit{pp} solar neutrinos is important for studying the Sun's energy mechanism, monitoring thermodynamic equilibrium, and studying neutrino oscillation in the vacuum-dominated region. For a large-scale liquid scintillator detector, one bottleneck for \textit{pp} solar neutrino detection comes from pile-up events of intrinsic $^{14}$C decays. This paper presents a few approaches to discriminate \textit{pp} solar neutrinos and $^{14}$C pile-up events by considering the difference in their time and spatial distributions. In this work, a Geant4-based Monte Carlo simulation is constructed. Then multivariate analysis and deep learning technology were adopted respectively to investigate the capability of $^{14}$C pile-up reduction. As a result, the BDTG model and VGG network showed good performance in discriminating \textit{pp} solar neutrinos and $^{14}$C double pile-up events. Their signal significance can achieve 10.3 and 15.6 using only one day of statistics. In this case, the signal efficiency is 51.1\% for discrimination using the BDTG model when rejecting 99.18\% $^{14}$C double pile-up events, and the signal efficiency is 42.7\% for the case using the VGG network when rejecting 99.81\% $^{14}$C double pile-up events.

hep-ex

Reconstruction of Muon Bundle in the JUNO Central Detector

The Jiangmen Underground Neutrino Observatory (JUNO) is a multi-purpose neutrino experiment. One of the main goals is to determine the neutrino mass ordering by precisely measuring the energy spectrum of reactor antineutrinos. For reactor antineutrino detection, cosmogenic backgrounds such as $^9$Li/$^8$He and fast neutrons induced by cosmic muons should be rejected carefully by applying muon veto cuts, which requires good muon track reconstruction. With a 20~kton liquid scintillator detector, simulation shows the proportion of muon bundles to be around 8\% in the JUNO, while its reconstruction is rarely discussed in previous experiments. According to the charge response of the PMT array, this paper proposes an efficient algorithm for muon bundle track reconstruction. This is the first reconstruction of muon bundles in a large volume liquid scintillator detector. Additionally, the algorithm shows good performance and potential in reconstruction for both single muon and double muons. The spatial resolution of single muon reconstruction is 20~cm and the angular resolution is $0.5^\circ$. As for double muon reconstruction, the spatial resolution and angular resolution could be 30~cm and $1.0^\circ$, respectively. Moreover, this paper has also discussed muon classification and veto strategy.

physics.ins-det

Multitask 3D CBCT-to-CT Translation and Organs-at-Risk Segmentation Using Physics-Based Data Augmentation

In current clinical practice, noisy and artifact-ridden weekly cone-beam computed tomography (CBCT) images are only used for patient setup during radiotherapy. Treatment planning is done once at the beginning of the treatment using high-quality planning CT (pCT) images and manual contours for organs-at-risk (OARs) structures. If the quality of the weekly CBCT images can be improved while simultaneously segmenting OAR structures, this can provide critical information for adapting radiotherapy mid-treatment as well as for deriving biomarkers for treatment response. Using a novel physics-based data augmentation strategy, we synthesize a large dataset of perfectly/inherently registered planning CT and synthetic-CBCT pairs for locally advanced lung cancer patient cohort, which are then used in a multitask 3D deep learning framework to simultaneously segment and translate real weekly CBCT images to high-quality planning CT-like images. We compared the synthetic CT and OAR segmentations generated by the model to real planning CT and manual OAR segmentations and showed promising results. The real week 1 (baseline) CBCT images which had an average MAE of 162.77 HU compared to pCT images are translated to synthetic CT images that exhibit a drastically improved average MAE of 29.31 HU and average structural similarity of 92% with the pCT images. The average DICE scores of the 3D organs-at-risk segmentations are: lungs 0.96, heart 0.88, spinal cord 0.83 and esophagus 0.66. This approach could allow clinicians to adjust treatment plans using only the routine low-quality CBCT images, potentially improving patient outcomes. Our code, data, and pre-trained models will be made available via our physics-based data augmentation library, Physics-ArX, at https://github.com/nadeemlab/Physics-ArX.

eess.IV

Generalizable Cone Beam CT Esophagus Segmentation Using Physics-Based Data Augmentation

Automated segmentation of esophagus is critical in image guided/adaptive radiotherapy of lung cancer to minimize radiation-induced toxicities such as acute esophagitis. We developed a semantic physics-based data augmentation method for segmenting esophagus in both planning CT (pCT) and cone-beam CT (CBCT) using 3D convolutional neural networks. 191 cases with their pCT and CBCTs from four independent datasets were used to train a modified 3D-Unet architecture with a multi-objective loss function specifically designed for soft-tissue organs such as esophagus. Scatter artifacts and noise were extracted from week 1 CBCTs using power law adaptive histogram equalization method and induced to the corresponding pCT followed by reconstruction using CBCT reconstruction parameters. Moreover, we leverage physics-based artifact induced pCTs to drive the esophagus segmentation in real weekly CBCTs. Segmentations were evaluated using geometric Dice and Hausdorff distance as well as dosimetrically using mean esophagus dose and D5cc. Due to the physics-based data augmentation, our model trained just on the synthetic CBCTs was robust and generalizable enough to also produce state-of-the-art results on the pCTs and CBCTs, achieving 0.81 and 0.74 Dice overlap. Our physics-based data augmentation spans the realistic noise/artifact spectrum across patient CBCT/pCT data and can generalize well across modalities with the potential to improve the accuracy of treatment setup and response analysis.

eess.IV

Design and characterization of high energy micro-CT with a laser-based X-ray source

The increasingly demand for machining accuracy and product quality excites a great interest in high-resolution non-destructive testing (NDT) methods, but spatial resolution of conventional high-energy computed tomography (CT) is limited to sub-millimeter because of large X-ray spot size. Therefore, we propose a novel high-resolution high-energy CT based on laser-driven X-ray source and prove its feasibility to allow high-spatial-resolution tomographic imaging of dense objects. A numerical model is developed with a consideration of realistic factors including parameter fluctuations, statistical noise and detecting efficiency. By using modulation transfer functions, the system performance is quantitatively characterized and optimized in terms of source characteristics, detector aperture, geometrical configuration and projection parameters. As a result, the simulated tomography for a high-density object (up to 19.35g/cm3) achieves a basic spatial resolution of 64.9μm. This concept expands the prospects of laser-based compact X-ray sources and shows a great potential to achieve high-perspectivity micro-CT imaging for various industrial applications.

physics.ins-det