SearcharxivSearch

arXiv subjects

Silvia Capelli

Publications and source records attributed to Silvia Capelli.

4 recordsLinked to original sources

Measurement of the $^{99}$Tc $β$ spectrum with Silicon Drift Detectors

The need for reliable calculations of Nuclear Matrix Elements is compelling for the next generation of neutrinoless double-beta decay experiments. This requires nuclear models to be validated against experimental data, such as non-unique forbidden $β$ decays, which have been found sensitive to details in nuclear calculations, most importantly to the renormalization of the axial and vector currents. %, parametrized as a quenching of $g_A$ and $g_V$. We report here a measurement of the 2$^{nd}$ forbidden $^{99}$Tc $β$ spectrum performed for the first time with Silicon Drift Detectors, state-of-the-art semiconductor detectors for low-energy spectroscopy. We designed a novel hybrid spectrometer using a LYSO crystal read by a SiPM to precisely calibrate our main detector and to accurately measure the background. We then compared our measured spectrum with one obtained using cryogenic calorimeters, as well as with predictions from the Realistic Shell Model. Starting from Realistic Shell Model calculations performed with Bare decay operators, we carried out a Bayesian analysis to extract the average quenching factors required to reproduce both the measured spectral shape and the experimental half-life, obtaining $q_{g_A}=0.40(1)$ and $q_{g_V}=0.47(1)$. These values quantify the average renormalization of the axial and vector currents, respectively, and were compared with those predicted by RSM calculations employing Effective decay operators, thereby providing a benchmark for assessing the ability of the model to describe the second-forbidden $β$ decay of $^{99}\mathrm{Tc}$. More broadly, this comparison tests the reliability of the theoretical framework also used to predict $0νββ$ nuclear matrix elements.

nucl-ex

Broadband parametric amplification in DARTWARS

Superconducting parametric amplifiers offer the capability to amplify feeble signals with extremely low levels of added noise, potentially reaching quantum-limited amplification. This characteristic makes them essential components in the realm of high-fidelity quantum computing and serves to propel advancements in the field of quantum sensing. In particular, Traveling-Wave Parametric Amplifiers (TWPAs) may be especially suitable for practical applications due to their multi-Gigahertz amplification bandwidth, a feature lacking in Josephson Parametric Amplifiers (JPAs), despite the latter being a more established technology. This paper presents recent developments of the DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) project, focusing on the latest prototypes of Kinetic Inductance TWPAs (KITWPAs). The project aims to develop a KITWPA capable of achieving $20\,$ dB of amplification. To enhance the production yield, the first prototypes were fabricated with half the length and expected gain of the final device. In this paper, we present the results of the characterization of one of the half-length prototypes. The measurements revealed an average amplification of approximately $9\,$dB across a $2\,$GHz bandwidth for a KITWPA spanning $17\,$mm in length.

quant-ph

Electron spectrometry with SDDs: a GEANT4 based method for detector response reconstruction

Electron spectrometry is traditionally challenging due to the difficulty of correctly reconstructing the original energy of the detected electrons. Silicon Drift Detectors, extensively used for X-ray spectrometry, are a promising technology for the precise measurement of electrons energy. The ability to correctly model the detector entrance window response to the energy deposited by electrons is a critical aspect of this application. We hereby describe a MonteCarlo-based approach to this problem, together with characterization and validation measurements performed with electron beams from a Scanning Electron Microscope.

physics.ins-det

A flexible scintillation light apparatus for rare event searches

Compelling experimental evidences of neutrino oscillations and their implication that neutrinos are massive particles have given neutrinoless double beta decay a central role in astroparticle physics. In fact, the discovery of this elusive decay would be a major breakthrough, unveiling that neutrino and antineutrino are the same particle and that the lepton number is not conserved. It would also impact our efforts to establish the absolute neutrino mass scale and, ultimately, understand elementary particle interaction unification. All current experimental programs to search for neutrinoless double beta decay are facing with the technical and financial challenge of increasing the experimental mass while maintaining incredibly low levels of spurious background. The new concept described in this paper could be the answer which combines all the features of an ideal experiment: energy resolution, low cost mass scalability, isotope choice flexibility and many powerful handles to make the background negligible. The proposed technology is based on the use of arrays of silicon detectors cooled to 120 K to optimize the collection of the scintillation light emitted by ultra-pure crystals. It is shown that with a 54 kg array of natural CaMoO4 scintillation detectors of this type it is possible to yield a competitive sensitivity on the half-life of the neutrinoless double beta decay of 100Mo as high as ~10E24 years in only one year of data taking. The same array made of 40CaMoO4 scintillation detectors (to get rid of the continuous background coming from the two neutrino double beta decay of 48Ca) will instead be capable of achieving the remarkable sensitivity of ~10E25 years on the half-life of 100Mo neutrinoless double beta decay in only one year of measurement.

physics.ins-det