Searcharxiv⌕ Search

arXiv subjects

Simon Johannes Joham

Publications and source records attributed to Simon Johannes Joham.

4 recordsLinked to original sources

Zero-Shot Brain MRI Inpainting with 2.5D Unconditional Flow Priors

Generative inpainting of brain MRI volumes is essential for synthesizing healthy tissue in pathological regions, improving the accuracy and reliability of automated downstream brain analysis applications such as image registration, brain extraction, and segmentation. However, standard 3D approaches are computationally prohibitive, while efficient 2D slice-wise methods suffer from severe inter-slice discontinuities. Furthermore, traditional models rely on conditional training, requiring task-specific learning of masked inputs. We propose a zero-shot brain MRI inpainting framework utilizing 2.5D unconditional flow priors to capture spatial context along the superior-inferior axis without the overhead of full 3D convolutions. During training, our flow matching model learns the joint distribution of adjacent axial slice triplets, modeling the manifold of healthy brain anatomy while explicitly excluding pathological regions from the loss function. At inference, the model processes the input triplets autoregressively along the depth axis. We employ the Restora-Flow solver to constrain the unconditional prior using the input mask, achieving accurate zero-shot inpainting. Evaluations show our 2.5D strategy resolves the structural discontinuities of 2D baselines, synthesizing plausible healthy tissue while maintaining volumetric consistency across the axial, sagittal, and coronal planes. As a final step, we generate and average an ensemble of multiple stochastic reconstructions to form the final prediction. Quantitative results benchmarked on the official BraTS 2026 Inpainting Challenge validation set demonstrate the effectiveness of our proposed approach, yielding an SSIM of 0.816 $\pm$ 0.112, MSE of 0.007 $\pm$ 0.005, and PSNR of 22.923 $\pm$ 4.343. Code is available at https://github.com/imigraz/brats2026-inpainting.

cs.CV↗

Flow Matching for Conditional MRI-CT and CBCT-CT Image Synthesis

Generating synthetic CT (sCT) from MRI or CBCT plays a crucial role in enabling MRI-only and CBCT-based adaptive radiotherapy, improving treatment precision while reducing patient radiation exposure. To address this task, we adopt a fully 3D Flow Matching (FM) framework, motivated by recent work demonstrating FM's efficiency in producing high-quality images. In our approach, a Gaussian noise volume is transformed into an sCT image by integrating a learned FM velocity field, conditioned on features extracted from the input MRI or CBCT using a lightweight 3D encoder. We evaluated the method on the SynthRAD2025 Challenge benchmark, training separate models for MRI to sCT and CBCT to sCT across three anatomical regions: abdomen, head and neck, and thorax. Validation and testing were performed through the challenge submission system. The results indicate that the method accurately reconstructs global anatomical structures; however, preservation of fine details was limited, primarily due to the relatively low training resolution imposed by memory and runtime constraints. Future work will explore patch-based training and latent-space flow models to improve resolution and local structural fidelity.

cs.CV↗

Restora-Flow: Mask-Guided Image Restoration with Flow Matching

Flow matching has emerged as a promising generative approach that addresses the lengthy sampling times associated with state-of-the-art diffusion models and enables a more flexible trajectory design, while maintaining high-quality image generation. This capability makes it suitable as a generative prior for image restoration tasks. Although current methods leveraging flow models have shown promising results in restoration, some still suffer from long processing times or produce over-smoothed results. To address these challenges, we introduce Restora-Flow, a training-free method that guides flow matching sampling by a degradation mask and incorporates a trajectory correction mechanism to enforce consistency with degraded inputs. We evaluate our approach on both natural and medical datasets across several image restoration tasks involving a mask-based degradation, i.e., inpainting, super-resolution and denoising. We show superior perceptual quality and processing time compared to diffusion and flow matching-based reference methods.

cs.CV↗

Synthetic Augmentation for Anatomical Landmark Localization using DDPMs

Deep learning techniques for anatomical landmark localization (ALL) have shown great success, but their reliance on large annotated datasets remains a problem due to the tedious and costly nature of medical data acquisition and annotation. While traditional data augmentation, variational autoencoders (VAEs), and generative adversarial networks (GANs) have already been used to synthetically expand medical datasets, diffusion-based generative models have recently started to gain attention for their ability to generate high-quality synthetic images. In this study, we explore the use of denoising diffusion probabilistic models (DDPMs) for generating medical images and their corresponding heatmaps of landmarks to enhance the training of a supervised deep learning model for ALL. Our novel approach involves a DDPM with a 2-channel input, incorporating both the original medical image and its heatmap of annotated landmarks. We also propose a novel way to assess the quality of the generated images using a Markov Random Field (MRF) model for landmark matching and a Statistical Shape Model (SSM) to check landmark plausibility, before we evaluate the DDPM-augmented dataset in the context of an ALL task involving hand X-Rays.

cs.CV↗