SearcharxivSearch

arXiv subjects

Simona Lombardo

Publications and source records attributed to Simona Lombardo.

16 recordsLinked to original sources

Experimental study of the first telescope with a toroidal curved detector

We describe a practical implementation of the anamorphically curved detector concept. In order to demonstrate its advantages, a telescope lab prototype was developed, built, and tested. It is based on a 4-mirror all-spherical unobscured design, similar to that proposed by D. Shafer. The telescope is open at F/#=5.5 and its extended field of view is 10.6x8 degrees. We explore the design parameter space to demonstrate the change in gain introduced by the curved detector and to substantiate the chosen parameters. If the image surface is curved to the shape of a toroid, the image quality reaches the diffraction limit over the entire field by design. The design was optimized to use standard concave spherical mirrors. The detector was curved down toroidally with an exquisite surface precision of approximately 11 micrometers Peak-to-Valley. The experimental tests of the prototype have shown that use of the toroidally curved detector allows to increase the contrast in the field corner by up to 0.3 units, which is in good agreement with the modeling results. We also propose a few prospective applications of the demonstrated concept.

astro-ph.IM

The detectability of high-redshift gamma-ray bursts near-infrared afterglows with CAGIRE

Context. Transient sky astronomy is entering a new era with the advent of the SVOM mission (Space Variable Objects Monitor), which was successfully launched on the 26th of June, 2024. The primary goal of SVOM is to monitor the hard X-ray sky searching for gamma-ray bursts (GRBs). On top of its on-board follow-up capabilities, SVOM will be backed by its ground segment composed of several facilities, of which the near-infrared imager CAGIRE. Mounted on the robotic telescope COLIBRI, it will be a unique instrument, able to perform fast follow-up of GRB afterglows in J and H bands, an ideal combination to catch high-redshift (z>6) and/or obscured GRBs. Aims. This paper aims at estimating the performances of CAGIRE for GRB near-infrared afterglow detection based on the characteristics of the detector and the specificities of the COLIBRI telescope. Quickly fading GRB afterglows pose challenges that should be addressed by adapting observing strategies to the capabilities of CAGIRE. Methods. We use an end-to-end image simulator to produce realistic CAGIRE images, taking into account results from the characterization of the ALFA detector used by CAGIRE. We implemented a GRB afterglow generator that simulates infrared lightcurves and spectra based on published observation of distant GRBs (z>6). Results. We retrieved the photometry of 9 GRB afterglows in various scenarios covered by CAGIRE. Catching afterglows as early as two minutes after burst allows the identification of a nIR counterpart in the brightest 4 events. When artificially redshifted even further away, these events remain detectable by CAGIRE up to z=9.6 in J band, and z=13.3 in H band, indicating the potential of CAGIRE to be a pioneer in the identification of the most distant GRBs to date.

astro-ph.HE

CAGIRE: a wide-field NIR imager for the COLIBRI 1.3 meter robotic telescope

The use of high energy transients such as Gamma Ray Bursts (GRBs) as probes of the distant universe relies on the close collaboration between space and ground facilities. In this context, the Sino-French mission SVOM has been designed to combine a space and a ground segment and to make the most of their synergy. On the ground, the 1.3 meter robotic telescope COLIBRI, jointly developed by France and Mexico, will quickly point the sources detected by the space hard X-ray imager ECLAIRs, in order to detect and localise their visible/NIR counterpart and alert large telescopes in minutes. COLIBRI is equipped with two visible cameras, called DDRAGO-blue and DDRAGO-red, and an infrared camera, called CAGIRE, designed for the study of high redshift GRBs candidates. Being a low-noise NIR camera mounted at the focus of an alt-azimutal robotic telescope imposes specific requirements on CAGIRE. We describe here the main characteristics of the camera: its optical, mechanical and electronics architecture, the ALFA detector, and the operation of the camera on the telescope. The instrument description is completed by three sections presenting the calibration strategy, an image simulator incorporating known detector effects, and the automatic reduction software for the ramps acquired by the detector. This paper aims at providing an overview of the instrument before its installation on the telescope.

astro-ph.IM

Flux reconstruction for the NIR camera CAGIRE at the focus of the Colibrí telescope

CAGIRE is the near infrared camera of the Colibrí robotic telescope, designed for the follow-up of SVOM alerts. It is based on the ALFA 2k x 2k detector, from the LYNRED French Company, operating in "Up the Ramp" mode. An observation consists in a series of short (1-2 minutes) exposures during which the pixels are read out every 1.3 second, while continuously accumulating charges proportionally to the received flux. We discuss here the preprocessing of CAGIRE data and a method that can be used to recover the flux received by each pixel from the slope of the ramp.

astro-ph.IM

3D printing for astronomical mirrors

3D printing, also called additive manufacturing, offers a new vision for optical fabrication in term of achievable optical quality and reduction of weight and cost. In this paper we describe two different ways to use this technique in the fabrication process. The first method makes use of 3D printing in the fabrication of warping harnesses for stress polishing, and we apply that to the fabrication of the WFIRST coronagraph off axis parabolas. The second method considers a proof of concept for 3D printing of lightweight X-Ray mirrors, targeting the next generation of X-rays telescopes. Stress polishing is well suited for the fabrication of the high quality off axis parabolas required by the coronagraph to image exoplanets.. Here we describe a new design of warping harness which can generate astigmatism and coma with only one actuator. The idea is to incorporate 3D printing in the manufacturing of the warping harness. The method depicted in this paper demonstrates that we reach the tight precision required at the mirrors surface. Moreover the error introduced by the warping harness fabricated by 3D printing does not impact the final error budget. Concerning the proof of concept project, we investigate 3D printing towards lightweight X-ray mirrors. We present the surface metrology of test samples fabricated by stereo lithography (SLA) and Selective Laser Sintering (SLS) with different materials. The lightweighting of the samples is composed of a series of arches. By complementing 3D printing with finite element analysis topology optimization we can simulate a specific optimum shape for the given input parameters and external boundary conditions. The next set of prototypes is designed taking to account the calculation of topology optimisation.

astro-ph.IM

Superpolished OAPs for WFIRST CGI

Exoplanet imaging requires super polished off-axis parabolas (OAP) with the utmost surface quality. In this paper we describe an innovative manufacturing process combining 3D printing and stress polishing, to create a warping harness capable of producing any off axis parabola profile with a single actuator. The warping harness is manufactured by 3D printing. This method will be applied to the production of the WFIRST coronagraph's off axis parabolas. The evolution of the warping harness design is presented, starting from a ring warping harness generating astigmatism, to an innovative thickness distribution harness optimised to generate an off axis parabola shape. Several design options are available for the prototyping phase, with their advantages and disadvantages which will be discussed.

astro-ph.IM

Next-generation telescopes with curved focal surface for ultra-low surface brightness surveys

In spite of major advances in both ground- and space-based instrumentation, the ultra-low-surface brightness universe (ULSB) still remains a largely unexplored volume in observational parameter space. ULSB observations provide unique constraints on a wide variety of objects, from the Zodiacal light all the way to the optical cosmological background radiation, through dust cirri, mass loss shells in giant stars, LSB galaxies and the intracluster light. These surface brightness levels (>28-29 mag arcsec^-2) are observed by maximising the efficiency of the surveys and minimising or removing the systematics arising in the measurement of surface brightness. Based on full-system photon Monte Carlo simulations, we present here the performance of a ground-based telescope aimed at carrying out ULSB observations, with a curved focal surface design. Its off-axis optical design maximises the field of view while minimising the focal ratio. No lenses are used, as their multiple internal scatterings increase the wings of the point spread function (PSF), and the usual requirement of a flat focal plane is relaxed through the use of curved CCD detectors. The telescope has only one unavoidable single refractive surface, the cryostat window, and yet it delivers a PSF with ultra-compact wings, which allows the detection, for a given exposure time, of surface brightness levels nearly three orders of magnitude fainter than any other current telescope.

astro-ph.IM

Design and modelling of spectrographs with holographic gratings on freeform surfaces

In the present paper we demonstrate the approach of using a holographic grating on a freeform surface for advanced spectrographs design. We discuss the surface and groove pattern description used for ray-tracing. Moreover, we present a general procedure of diffraction efficiency calculation, which accounts for the change of hologram recording and operation conditions across the surface. The primary application of this approach is the optical design of the POLLUX spectropolarimeter for the LUVOR mission project where a freeform holographic grating operates simultaneously as a cross-disperser and a camera with high resolution and high dispersion. The medium ultraviolet channel design of POLLUX is considered in detail as an example. Its resolving power reaches [126,000-133,000] in the region of 118.5-195 nm. Also, we show a possibility to use a similar element working in transmission to build an unobscured double-Schmidt spectrograph. The spectral resolving power reaches 4000 in the region 350-550 nm and remains stable along the slit.

astro-ph.IM

Curved detectors developments and characterization: application to astronomical instruments

Many astronomical optical systems have the disadvantage of generating curved focal planes requiring flattening optical elements to project the corrected image on flat detectors. The use of these designs in combination with a classical flat sensor implies an overall degradation of throughput and system performances to obtain the proper corrected image. With the recent development of curved sensor this can be avoided. This new technology has been gathering more and more attention from a very broad community, as the potential applications are multiple: from low-cost commercial to high impact scientific systems, to mass-market and on board cameras, defense and security, and astronomical community. We describe here the first concave curved CMOS detector developed within a collaboration between CNRS- LAM and CEA-LETI. This fully-functional detector 20 Mpix (CMOSIS CMV20000) has been curved down to a radius of Rc = 150 mm over a size of 24x32 mm^2 . We present here the methodology adopted for its characterization and describe in detail all the results obtained. We also discuss the main components of noise, such as the readout noise, the fixed pattern noise and the dark current. Finally we provide a comparison with the flat version of the same sensor in order to establish the impact of the curving process on the main characteristics of the sensor.

astro-ph.IM

Design of optical systems with toroidal curved detectors

We consider using toroidal curved detectors to improve the performance of imaging optical systems. We demonstrate that some optical systems have an anamorphic field curvature. We consider an unobscured re-imaging three-mirror anastigmat as an example (f'=960 mm, F/5.3, FoV 4x4 degrees). By assuming that the image is focused on a toroidal detector surface and perform re-optimization, it becomes possible to obtain a notable gain in the image quality - up to 40 % in terms of the spot RMS radius. Through analytic computations and finite-element analysis, we demonstrate that this toroidal shape can be obtained by bending of a thinned detector in a relatively simple setup.

astro-ph.IM

POLLUX: a UV spectropolarimeter for the LUVOIR space telescope project

The present paper describes the current baseline optical design of POLLUX, a high-resolution spectropolarimeter for the future LUVOIR mission. The instrument will operate in the ultraviolet (UV) domain from 90 to 390 nm in both spectropolarimetric and pure spectroscopic modes. The working range is split between 3 channels -- far (90-124.5 nm), medium (118.5-195 nm) and near (195-390 nm) UV. Each of the channels is composed of a polarimeter followed by an echelle spectrograph consisting of a classical off-axis paraboloid collimator, echelle grating with a high grooves frequency and a cross-disperser grating operating also as a camera. The latter component integrates some advanced technologies: it is a blazed grating with a complex grooves pattern formed by holographic recording, which is manufactured on a freeform surface. One of the key features underlying the current design is the large spectral length of each order ~6 nm, which allows to record wide spectral lines without any discontinuities. The modelling results show that the optical design will provide the required spectral resolving power higher than R ~ 120,000 over the entire working range for a point source object with angular size of 30 mas. It is also shown that with the 15-m primary mirror of the LUVOIR telescope the instrument will provide an effective collecting area up to 38 569 cm 2. Such a performance will allow to perform a number of groundbreaking scientific observations. Finally, the future work and the technological risks of the design are discussed in details.

astro-ph.IM

Curved detectors for wide field imaging systems: impact on tolerance analysis

In the present paper we consider quantitative estimation of the tolerances widening in optical systems with curved detectors. The gain in image quality allows to loosen the margins for manufacturing and assembling errors. On another hand, the requirements for the detector shape and positioning become more tight. We demonstrate both of the effects on example of two optical designs. The first one is a rotationally-symmetrical lens with focal length of 25 mm, f-ratio of 3.5 and field of view equal to 72$^\circ$, working in the visible domain. The second design is a three-mirror anastigmat telescope with focal length of 250 mm, f-ratio of 2.0 and field of view equal to $4^\circ \times 4^\circ$. In both of the cases use of curved detectors allow to increase the image quality and substantially decrease the requirements for manufacturing precision

astro-ph.IM

Advanced optical designs of curved detectors-based two-mirrors unobscured telescopes

In the present paper we consider a family of unobscured telescope designs with curved detectors. They are based on classical two-mirror schemes -- Ritchey-Chretien, Gregorian and Couder telescopes. It is shown that all the designs provide nearly diffraction limited image quality in the visible domain for $.4^\circ \times .4^\circ$ field of view with the f-number of 7. We also provide a brief ghost analysis and point on special features of the systems with curved detectors. Finally, the detector surface shape obtained in each case is analyzed and its' technological feasibility is demonstrated.

astro-ph.IM

Spectrographs with holographic gratings on freeform surfaces: design approach and application for the LUVOIR mission

In the present paper we demonstrate the approach to use a holographic grating on a freeform surface for advanced spectrographs design. On the example POLLUX spectropolarimeter medium-UV channel we chow that such a grating can operate as a cross-disperser and a camera mirror at the same time. It provides the image quality high enough to reach the spectral resolving power of 126 359-133 106 between 11.5 and 195 nm, which is higher than the requirement. Also we show a possibility to use a similar element working in transmission to build an unobscured double-Schmidt spectrograph. The spectral resolving power reaches 2750 for a long slit. It is also shown that the parameters of both the gratings are feasible with the current technologies.

astro-ph.IM

A fast, wide-field and distortion-free telescope with curved detectors for surveys at ultra-low surface brightness

We present the design of an all-reflective, bi-folded Schmidt telescope aimed at surveys of extended astronomical objects with extremely-low surface brightness. The design leads to a high image quality without any diffracting spider, along with a large aperture and field of view, with a small central obstruction which barely alters the PSF. As an example, we present the design of a high-quality, 36 cm diameter, fast ( f /2.5) telescope working in the visible with a large field of view (1.6°x 2.6°). The telescope can operate with a curved detector (or with a flat detector with a field flattener) and a set of filters. The entrance mirror is anamorphic and replaces the classical Schmidt entrance corrector plate. We show that this anamorphic primary mirror can be manufactured through stress polishing, avoiding high spatial frequency errors, and tested with a simple interferometer scheme. This prototype is intended to serve as a fast-track scientific and technological pathfinder for the future space-based MESSIER mission.

astro-ph.IM

A flux calibration device for the SuperNova Integral Field Spectrograph (SNIFS)

Observational cosmology employing optical surveys often require precise flux calibration. In this context we present SNIFS Calibration Apparatus (SCALA), a flux calibration system developed for the SuperNova Integral Field Spectrograph (SNIFS), operating at the University of Hawaii 2.2 m telescope. SCALA consists of a hexagonal array of 18 small parabolic mirrors distributed over the face of, and feeding parallel light to, the telescope entrance pupil. The mirrors are illuminated by integrating spheres and a wavelength-tunable (from UV to IR) light source, generating light beams with opening angles of 1 degree. These nearly parallel beams are flat and flux-calibrated at a subpercent level, enabling us to calibrate our "telescope + SNIFS system" at the required precision.

astro-ph.IM