SearcharxivSearch

arXiv subjects

Simone Savazzi

Publications and source records attributed to Simone Savazzi.

6 recordsLinked to original sources

Measurement of 80-200 MeV/n $^{16}$O nuclear cross-section on Carbon and Polyethylene targets with the nuclear emulsion detector of the FOOT experiment

Accurate knowledge of nuclear fragmentation cross-sections is essential for optimizing charged particle therapy. In this study, conducted within the framework of the FOOT (FragmentatiOn Of Target) experiment, we present the first measurements with a large angular acceptance of total charge-changing cross-section and the cross-section for the production of fragments (production cross-section) for $^{16}$O ions interacting with Carbon (C) and Polyethylene (C$_2$H$_4$) targets in the kinetic energy range of 80 to 200 MeV/nucleon. Measurements were performed using the Emulsion Cloud Chamber (ECC) technique, which combines high spatial resolution and angular acceptance, up to 45$^\circ$. The results are compared with Monte Carlo model predictions. Moreover, the total charge-changing and fragment production cross-sections for $^{16}$O on Hydrogen in the same energy range are derived.

nucl-ex

Prompt Gamma Timing for range verification with carbon ion irradiation: first experimental measurements and comparison with Geant4 Monte Carlo simulations

Prompt Gamma Timing (PGT) is a promising technique for in vivo range verification in particle therapy, exploiting the time-of-flight between primary particles and prompt gamma rays emitted by nuclear interactions. PGT distribution is highly sensitive to beam energy and target density, which, under controlled detector positioning, enables real-time monitoring of particle range, detection of morphological changes, and support for adaptive treatment strategies. This study investigates for the first time the application of PGT in carbon ion therapy. Measurements were performed using a dedicated detection system composed of a silicon strip sensor for primary ion timing and a LaBr3(Ce) read out by a SiPM for secondary radiation. Carbon ion beams with energies of 166.41, 268.86, and 398.84 MeV/u irradiated a homogeneous 30.0 cm PMMA target at CNAO. The secondary radiation detector was positioned at four off-beam positions to assess the robustness of the PGT technique. Simulations based on Geant4 were conducted for all configurations to evaluate agreement and predictive capability. A bin-by-bin comparison of experimental and simulated PGT intensities demonstrated strong agreement within the 95% confidence interval, with no incompatible bins at 166.41 MeV/u, at most 1% at 268.86 MeV/u, and up to 8% at 398.84 MeV/u, depending on detector position. Photons were identified as the dominant contribution to the detected signals, particularly for detector positions upstream with respect to the primary particle beam, minimizing signal contamination from neutrons and charged fragments. The validated experimental-simulation framework confirms the capability of the proposed PGT system to resolve energy-dependent differences and highlights its potential for detecting clinically relevant changes in the particle beam range, supporting further development toward real-time monitoring in carbon ion therapy.

physics.med-ph

Mixed Ion Beams Enable Simultaneous Treatment and Real-Time Imaging in Carbon Ion Therapy

Carbon ion therapy is one of the most advanced forms of radiotherapy, promising improved efficacy against resistant cancers. However, the high precision offered by the carbon ion Bragg peak requires precise knowledge of the beam range inside the patient. We report the first experimental realization of range monitoring and portal imaging with a mixed ion beam, where carbon ions are treating the tumor while helium ions simultaneously accelerated to the same velocity fully traverse the patient and provide treatment feedback. Using the GSI synchrotron, a beam of 12C3+ and 4He1+ ions is accelerated, exploiting their nearly identical charge-to-mass ratios. Stable extraction with controlled helium fractions down to 7% is demonstrated. Beam characterization reveals that the helium ion Bragg peak can be cleanly separated from the carbon ion fragment background which enables accurate detection of sub-millimeter Bragg peak displacements. Mixed-beam radiographs of a lung-cancer-like phantom offer target position detection to better than 0.5 mm accuracy. This establishes mixed beams as a powerful modality for real-time image guidance in carbon ion therapy, uniquely providing simultaneous treatment delivery, range probing, and portal imaging. By overcoming range uncertainty inside the patient, mixed beams will enable to fully exploit the precision of carbon ion therapy.

physics.med-ph

Prompt Gamma Timing in Carbon Therapy: First Experimental Results with the TIARA Detector

In the context of range monitoring for particle therapy, this study presents the first experimental results obtained with the TIARA detector using carbon-ion beams at the CNAO clinical center in Pavia, Italy. TIARA is based on the Prompt Gamma Timing (PGT) technique, which measures the time of flight (TOF) between incident ions and prompt gamma rays (PGs) emitted during nuclear interactions in the target. While the TIARA prototype has previously been validated with protons, carbons present a more challenging scenario due to their higher linear energy transfer, nuclear fragmentation products, and the continuous beam time structure of synchrotron accelerators. Experiments were performed by irradiating PMMA targets of different thicknesses with 200 MeV/u carbon beams. A coincidence time resolution of 279$\pm$35 ps FWHM was achieved, outperforming results previously obtained with protons at the same facility. A range accuracy of 4.74$\pm$0.36 mm at a 2$\sigma$ confidence level was measured at clinical intensity, when considering 5600 detected PGs, corresponding to the grouping of four irradiation spots of 2.4$\cdot$10$^6$ ions each. Overall, the results demonstrate that PGT-based range monitoring remains viable for carbon-ion beams, although increased background from secondary protons indicates that detector configuration adaptations are required.

physics.med-ph

Characterisation of a low-momentum high-rate muon beam monitor for the FAMU experiment at the CNAO-XPR beam facility

The FAMU experiment aims at an indirect measurement of the Zemach radius of the proton. The measurement is carried out on muonic hydrogen atoms produced through the low-momentum (50-60 MeV/c) muon beam a the RIKEN-RAL negative muon facility. The particle flux plays an important role in this measurement, as it is proportional to the number of muonic hydrogen atoms produced, which is the target of the FAMU experimental method. The beam monitor calibration technique and results, presented here, are meant to extract a reliable estimation of the muon flux during the FAMU data taking. These measurements were carried out at the CNAO synchrotron in Pavia, Italy, using proton beams and supported by Monte Carlo simulation of the detector in Geant4.

hep-ex

The FragmentatiOn Of Target Experiment (FOOT) and its DAQ system

The FragmentatiOn Of Target (FOOT) experiment aims to provide precise nuclear cross-section measurements for two different fields: hadrontherapy and radio-protection in space. The main reason is the important role the nuclear fragmentation process plays in both fields, where the health risks caused by radiation are very similar and mainly attributable to the fragmentation process. The FOOT experiment has been developed in such a way that the experimental setup is easily movable and fits the space limitations of the experimental and treatment rooms available in hadrontherapy treatment centers, where most of the data takings are carried out. The Trigger and Data Acquisition system needs to follow the same criteria and it should work in different laboratories and in different conditions. It has been designed to acquire the largest sample size with high accuracy in a controlled and online-monitored environment. The data collected are processed in real-time for quality assessment and are available to the DAQ crew and detector experts during data taking.

physics.ins-det