Searcharxiv⌕ Search

arXiv subjects

Sophie Djordjevic

Publications and source records attributed to Sophie Djordjevic.

3 recordsLinked to original sources

A primary quantum current standard based on the Josephson and the quantum Hall effects

The new definition of the ampere calls for a quantum current standard able to deliver a flow of elementary charges, $e$, controlled with a relative uncertainty of $10^{-8}$. Despite many efforts, nanodevices handling electrons one by one have never demonstrated such an accuracy for a net flow. The alternative route based on applying Ohm's law to the Josephson voltage and quantum Hall standards recently reached the target uncertainty in the milliampere range, but this was at the expense of the application of error corrections. Here, we present a new programmable quantum current generator, which combines both quantum standards and a superconducting cryogenic amplifier in a quantum electrical circuit enabling the current scaling without errors. Thanks to a full quantum instrumentation, we demonstrate the accuracy of the generated currents, in the microampere range, at quantized values, $\pm(n/p)ef_\mathrm{J}$, with relative uncertainties less than $10^{-8}$, where $n$ and $p$ are integer control parameters and $f_\mathrm{J}$ is the Josephson frequency. This experiment sets the basis of a universal quantum realization of the electrical units, for example able of improving high-value resistance measurements and bridging the gap with other quantum current sources.

cond-mat.mes-hall↗

Improvements of the programmable quantum current generator for better traceability of electrical current measurements

A programmable quantum current generator based on the application of Ohm's law to quantum voltage and resistance standards has demonstrated a realization of the ampere from the elementary charge with a $10^{-8}$ relative uncertainty [J. Brun-Picard et al. PRX 6, 041051, 2016]. Here, we report on improvements of the device leading to a noise reduction of the generated quantized current. The improved quantum current generator is used to calibrate different ammeters with lower measurement uncertainties. Besides, measurements of its quantized current using a calibrated Ultrastable Low-Noise Current Amplifier (ULCA) have shown that the realizations of the ampere at PTB (Physikalisch-Technische Bundesanstalt) and LNE (Laboratoire national de métrologie et d'essais) in the range $\pm50$ $μ$A agreed to -3.7 parts in $10^{7}$ with a combined standard uncertainty of 3.1 parts in $10^{7}$ (coverage factor $k_\mathrm{c}=1$).

physics.ins-det↗

Validation of the ultrastable low-noise current amplifier as travelling standard for small direct currents

An interlaboratory comparison of small-current generation and measurement capability is presented with the ultrastable low-noise current amplifier (ULCA) acting as travelling standard. Various measurements at direct currents between 0.16 nA and 13 nA were performed to verify the degree of agreement between the three national metrology institutes involved in the study. Consistency well within one part per million (ppm) was found. Due to harsh environmental conditions during shipment, the ULCA's transfer accuracy had been limited to about +/-0.4 ppm. Supplemental measurements performed at PTB indicate that further improvements in accuracy are possible. Relative uncertainties of 0.1 ppm are achieved by applying on-site calibration of the ULCA with a suitable cryogenic current comparator.

physics.ins-det↗