Searcharxiv⌕ Search

arXiv subjects

Soraia Ventura

Publications and source records attributed to Soraia Ventura.

2 recordsLinked to original sources

Expert-level detection of low-voltage intervals in EEG as a robust biomarker of neonatal encephalopathy

Background: Discontinuity in neonatal EEG is a critical marker of brain dysfunction but can be difficult to quantify visually. Inter-burst intervals (IBIs) are a key characteristic of discontinuity, yet their definition does not easily translate to AI detection. Objectives: To introduce low-voltage intervals (LVIs), defined exclusively by amplitude and duration, as a context-independent alternative to IBIs, develop an AI detection method for LVIs, and assess their clinical utility as a marker of brain injury. Methods: We developed a ConvNeXt model to detect LVIs and compared its performance with existing methods. We then tested the clinical relevance of detected LVIs across four applications: 1) grading background EEG abnormalities on an open benchmark dataset, 2) classifying clinical hypoxic-ischaemic encephalopathy (HIE) grades and comparing with a normal EEG dataset, 3) seizure prediction, and 4) association with seizure burden. Results: For training and validation, 654 hours of per-channel EEG from 123 neonates were reviewed and 51,162 LVIs were annotated. On held-out validation, ConvNeXt had an AUC of 0.996 and a Matthews correlation coefficient of 0.926. Model-reader agreement exceeded inter-reader agreement ($Δκ= 0.025$, 95% CI: 0.007 to 0.045, $p<0.001$), attaining expert-level equivalence. On a combined dataset of 444 neonates, percentage LVI showed a strong association with EEG grades (Spearman's $ρ=0.801$), a moderate association with HIE grades ($ρ=0.384$), a weaker association with seizure burden ($ρ=0.244$), and a strong seizure prediction capacity (AUC $=0.872$). Conclusion: AI detection of LVIs achieves expert-level equivalence, whereas quantitative features do not. Automated LVI quantification provides a robust clinical biomarker of neonatal encephalopathy associated with background EEG activity, HIE severity, and seizure risk.

cs.LG↗

Scaling convolutional neural networks achieves expert-level seizure detection in neonatal EEG

Background: Neonatal seizures are a neurological emergency that require urgent treatment. They are hard to diagnose clinically and can go undetected if EEG monitoring is unavailable. EEG interpretation requires specialised expertise which is not widely available. Algorithms to detect EEG seizures can address this limitation but have yet to reach widespread clinical adoption. Methods: Retrospective EEG data from 332 neonates was used to develop and validate a seizure-detection model. The model was trained and tested with a development dataset ($n=202$) that was annotated with over 12k seizure events on a per-channel basis. This dataset was used to develop a convolutional neural network (CNN) using a modern architecture and training methods. The final model was then validated on two independent multi-reviewer datasets ($n=51$ and $n=79$). Results: Increasing dataset and model size improved model performance: Matthews correlation coefficient (MCC) and Pearson's correlation ($r$) increased by up to 50% with data scaling and up to 15% with model scaling. Over 50k hours of annotated single-channel EEG was used for training a model with 21 million parameters. State-of-the-art was achieved on an open-access dataset (MCC=0.764, $r=0.824$, and AUC=0.982). The CNN attains expert-level performance on both held-out validation sets, with no significant difference in inter-rater agreement among the experts and among experts and algorithm ($Δκ< -0.095$, $p>0.05$). Conclusion: With orders of magnitude increases in data and model scale we have produced a new state-of-the-art model for neonatal seizure detection. Expert-level equivalence on completely unseen data, a first in this field, provides a strong indication that the model is ready for further clinical validation.

cs.LG↗