Neural network interpretability for forecasting of aggregated renewable generation

With the rapid growth of renewable energy, lots of small photovoltaic (PV) prosumers emerge. Due to the uncertainty of solar power generation, there is a need for aggregated prosumers to predict solar power generation and whether solar power generation will be larger than load. This paper presents two interpretable neural networks to solve the problem: one binary classification neural network and one regression neural network. The neural networks are built using TensorFlow. The global feature importance and local feature contributions are examined by three gradient-based methods: Integrated Gradients, Expected Gradients, and DeepLIFT. Moreover, we detect abnormal cases when predictions might fail by estimating the prediction uncertainty using Bayesian neural networks. Neural networks, which are interpreted by gradient-based methods and complemented with uncertainty estimation, provide robust and explainable forecasting for decision-makers.

cs.LG↗

Physics-Informed Neural Networks for Non-linear System Identification for Power System Dynamics

Varying power-infeed from converter-based generation units introduces great uncertainty on system parameters such as inertia and damping. As a consequence, system operators face increasing challenges in performing dynamic security assessment and taking real-time control actions. Exploiting the widespread deployment of phasor measurement units (PMUs) and aiming at developing a fast dynamic state and parameter estimation tool, this paper investigates the performance of Physics-Informed Neural Networks (PINN) for discovering the frequency dynamics of future power systems. PINNs have the potential to address challenges such as the stronger non-linearities of low-inertia systems, increased measurement noise, and limited availability of data. The estimator is demonstrated in several test cases using a 4-bus system, and compared with state of the art algorithms, such as the Unscented Kalman Filter (UKF), to assess its performance.

eess.SY↗

Design of a Continuous Local Flexibility Market with Network Constraints

To the best of our knowledge, this paper proposes for the first time a design of a continuous local flexibility market that explicitly considers network constraints. Continuous markets are expected to be the most appropriate design option during the early stages of local flexibility markets, where insufficient liquidity can hinder market development. At the same time, increasingly loaded distribution systems require to explicitly consider network constraints in local flexibility market clearing in order to help resolve rather than aggravate local network problems, such as line congestion and voltage issues. This paper defines the essential design considerations, introduces the local flexibility market clearing algorithm, and -- aiming to establish a starting point for future research -- discusses design options and research challenges that emerge during this procedure which require further investigation.

math.OC↗

Towards Optimal Coordination between Regional Groups: HVDC Supplementary Power Control

With Europe dedicated to limiting climate change and greenhouse gas emissions, large shares of Renewable Energy Sources (RES) are being integrated in the national grids, phasing out conventional generation. The new challenges arising from the energy transition will require a better coordination between neighboring system operators to maintain system security. To this end, this paper studies the benefit of exchanging primary frequency reserves between asynchronous areas using the Supplementary Power Control (SPC) functionality of High-Voltage Direct-Current (HVDC) lines. First, we focus on the derivation of frequency metrics for asynchronous AC systems coupled by HVDC interconnectors. We compare two different control schemes for HVDC converters, which allow for unilateral or bilateral exchanges of reserves between neighboring systems. Second, we formulate frequency constraints and include them in a unit commitment problem to ensure the N-1 security criterion. A data-driven approach is proposed to better represent the frequency nadir constraint by means of cutting hyperplanes. Our results suggest that the exchange of primary reserves through HVDC can reduce up to 10% the cost of reserve procurement while maintaining the system N-1 secure.

eess.SY↗

Capturing Power System Dynamics by Physics-Informed Neural Networks and Optimization

This paper proposes a tractable framework to determine key characteristics of non-linear dynamic systems by converting physics-informed neural networks to a mixed integer linear program. Our focus is on power system applications. Traditional methods in power systems require the use of a large number of simulations and other heuristics to determine parameters such as the critical clearing time, i.e. the maximum allowable time within which a disturbance must be cleared before the system moves to instability. The work proposed in this paper uses physics-informed neural networks to capture the power system dynamic behavior and, through an exact transformation, converts them to a tractable optimization problem which can be used to determine critical system indices. By converting neural networks to mixed integer linear programs, our framework also allows to adjust the conservativeness of the neural network output with respect to the existing stability boundaries. We demonstrate the performance of our methods on the non-linear dynamics of converter-based generation in response to voltage disturbances.

eess.SY↗

Market Integration of HVDC Lines: Cost Savings from Loss Allocation and Redispatching

In the Nordic region, many interconnectors are formed by HVDC links, as Scandinavia, Continental Europe and the Baltic region are non-synchronous AC systems. This paper presents two cost benefit analyses on the utilization of HVDC interconnectors in the Nordic countries: in the first we investigate the utilization of HVDC interconnectors for reserve procurement and, in the second, we assess the implementation of implicit grid losses on HVDC interconnectors in the day-ahead market. The first analysis is motivated by real events in 2018 where the inertia of the Nordic system dropped below a critical level and the most critical generating unit, a nuclear power plant in Sweden, was redispatched to guarantee the security of the system. In order to guarantee system security while reducing the costs of preventive actions, in summer 2020 new frequency products were introduced in the Nordic system: the Fast Frequency Reserves (FFR). HVDC lines, however, can perform similar tasks at lower costs. In our analysis, we are, thus, investigating the cost savings of using HVDC lines for frequency support using their Emergency Power Control (EPC) functionality, instead of redispatching or FFR. The second analysis is based on the proposition of Nordic Transmission System Operators (TSOs) to introduce linear HVDC loss factors in the market clearing. With our analysis, we show that linear loss factors can unfairly penalize one HVDC line over the other, and this can reduce social benefits and jeopardize revenues of merchant HVDC lines. In this regard, we propose piecewise-linear loss factors: a simple-to-implement but highly-effective solution. Moreover, we demonstrate how the introduction of HVDC loss factors is a partial solution, since it disproportionally increases the AC losses. Our results show that the additional inclusion of AC loss factors can eliminate this problem.

math.OC↗

Sharing Reserves through HVDC: Potential Cost Savings in the Nordic Countries

During summer 2018, the Nordic system's kinetic energy dropped below a critical level. As a consequence, Svenska kraftnät, the Swedish transmission system operator (TSO), requested the largest production unit to reduce its power output to guarantee system's security. This action resulted in a deviation from the generation dispatch determined by the market and in high costs for the Nordic TSOs. In this regard, this paper presents a tool for comparing mitigation strategies from an economic point of view and evaluates potential economic benefits of utilizing the Emergency Power Control (EPC) functionality of HVDC lines for the provision of fast reserves as a compliment to Frequency Containment Reserves (FCR). Moreover, the analysis is extended to the years 2020 and 2025 using inertia estimations from the Nordic TSOs. The findings of the paper suggest that the frequency of redispatching actions will increase in the future and that the cost of security for Nordic TSOs could be reduced by 70\% if HVDC links are used for frequency support.

eess.SY↗

Verification of Neural Network Behaviour: Formal Guarantees for Power System Applications

This paper presents for the first time, to our knowledge, a framework for verifying neural network behavior in power system applications. Up to this moment, neural networks have been applied in power systems as a black-box; this has presented a major barrier for their adoption in practice. Developing a rigorous framework based on mixed integer linear programming, our methods can determine the range of inputs that neural networks classify as safe or unsafe, and are able to systematically identify adversarial examples. Such methods have the potential to build the missing trust of power system operators on neural networks, and unlock a series of new applications in power systems. This paper presents the framework, methods to assess and improve neural network robustness in power systems, and addresses concerns related to scalability and accuracy. We demonstrate our methods on the IEEE 9-bus, 14-bus, and 162-bus systems, treating both N-1 security and small-signal stability.

eess.SY↗

Convex Relaxations of Chance Constrained AC Optimal Power Flow

High penetration of renewable energy sources and the increasing share of stochastic loads require the explicit representation of uncertainty in tools such as the optimal power flow (OPF). Current approaches follow either a linearized approach or an iterative approximation of non-linearities. This paper proposes a semidefinite relaxation of a chance constrained AC-OPF which is able to provide guarantees for global optimality. Using a piecewise affine policy, we can ensure tractability, accurately model large power deviations, and determine suitable corrective control policies for active power, reactive power, and voltage. We state a tractable formulation for two types of uncertainty sets. Using a scenario-based approach and making no prior assumptions about the probability distribution of the forecast errors, we obtain a robust formulation for a rectangular uncertainty set. Alternatively, assuming a Gaussian distribution of the forecast errors, we propose an analytical reformulation of the chance constraints suitable for semidefinite programming. We demonstrate the performance of our approach on the IEEE 24 and 118 bus system using realistic day-ahead forecast data and obtain tight near-global optimality guarantees.

eess.SY↗

Convex Relaxations of Probabilistic AC Optimal Power Flow for Interconnected AC and HVDC Grids

High Voltage Direct Current (HVDC) systems interconnect AC grids to increase reliability, connect offshore wind generation, and enable coupling of electricity markets. Considering the growing uncertainty in power infeed and the complexity introduced by additional controls, robust decision support tools are necessary. This paper proposes a chance constrained AC-OPF for AC and HVDC grids, which considers wind uncertainty, fully utilizes HVDC control capabilities, and uses the semidefinite relaxation of the AC-OPF. We consider a joint chance constraint for both AC and HVDC systems, we introduce a piecewise affine approximation to achieve tractability of the chance constraint, and we allow corrective control policies for HVDC converters and generators to be determined. An active loss penalty term in the objective function and a systematic procedure to choose the penalty weights allow us to obtain AC-feasible solutions. We introduce Benders decomposition to maintain scalability. Using realistic forecast data, we demonstrate our approach on a 53-bus and a 214-bus AC-DC system, obtaining tight near-global optimality guarantees. With a Monte Carlo analysis, we show that a chance constrained DC-OPF leads to violations, whereas our proposed approach complies with the joint chance constraint.

eess.SY↗

Second-Order Cone Relaxations of the Optimal Power Flow for Active Distribution Grids

Convex relaxations of the AC Optimal Power Flow (OPF) problem are essential not only for identifying the globally optimal solution but also for enabling the use of OPF formulations in Bilevel Programming and Mathematical Programs with Equilibrium Constraints (MPEC), which are required for solving problems such as the coordination between transmission and distribution system operator (TSO/DSO) or optimal network investment. Focusing on active distribution grids and radial networks, this paper introduces a framework that collects and compares, for the first time to our knowledge, the performance of the most promising convex OPF formulations for practical applications. Our goal is to establish a solid basis that will inform the selection of the most appropriate algorithm for different applications. This paper (i) introduces a unified mathematical and simulation framework, (ii) extends existing methods to retain exactness in a wider number of cases and (iii) consider reactive power injections. We conduct simulations on the IEEE 34 and 123 radial test feeders with distributed energy resources (DERs), using yearly solar irradiation and load data.

math.OC↗

Multi-Terminal DC Fault Identification for MMC-HVDC Systems based on Modal Analysis -- A Localized Protection Scheme

We propose a localized protection scheme based on modal analysis in multi-terminal modular multilevel converter (MMC) based high voltage DC (HVDC) systems. The paper addresses the issues of localized protection scheme based DC fault identification, such as differentiating between external and internal faults, classification of type of fault contingency i.e., pole to pole (\textit{PTP}) or pole to ground (\textit{PTG}) for high impedance faults (HIFs) in the system. The scheme works on equivalent network of multi-terminal MMC-HVDC system for a DC fault, using phase-modal transformation to analyse line-mode and zero-mode voltage across the current limiting reactor (CLR) for different possible contingencies in the presence of fault resistance. The protection scheme is validated to be reliable for HIFs and in the presence of White Gaussian Noise (WGN) in measurement. The scheme operation is validated to be intact for varying fault location, fault resistances and system transients.

eess.SY↗

Learning Optimal Power Flow: Worst-Case Guarantees for Neural Networks

This paper introduces for the first time a framework to obtain provable worst-case guarantees for neural network performance, using learning for optimal power flow (OPF) problems as a guiding example. Neural networks have the potential to substantially reduce the computing time of OPF solutions. However, the lack of guarantees for their worst-case performance remains a major barrier for their adoption in practice. This work aims to remove this barrier. We formulate mixed-integer linear programs to obtain worst-case guarantees for neural network predictions related to (i) maximum constraint violations, (ii) maximum distances between predicted and optimal decision variables, and (iii) maximum sub-optimality. We demonstrate our methods on a range of PGLib-OPF networks up to 300 buses. We show that the worst-case guarantees can be up to one order of magnitude larger than the empirical lower bounds calculated with conventional methods. More importantly, we show that the worst-case predictions appear at the boundaries of the training input domain, and we demonstrate how we can systematically reduce the worst-case guarantees by training on a larger input domain than the domain they are evaluated on.

cs.AI↗

North Sea Wind Power Hub: System Configurations, Grid Implementation and Techno-economic Assessment

In 2017, Energinet and TenneT, the Danish and Dutch Transmission System Operators (TSOs), have announced the North Sea Wind Power Hub (NSWPH) project. The project aims at increasing by 36 GW the North Sea offshore wind capacity, with an artificial island collecting all the power produced by wind turbines and several HVDC links transmitting this power to the onshore grids. This project brings together new opportunities and new challenges, both from a technical and economic point of view. In this regard, this paper presents three analyses regarding the design and operation of such an offshore system. First, we perform a techno-economic assessment of different grid configurations for the collection of the power produced by wind farms and its transmission to the hub. In this analysis, two frequencies and two voltage levels for the operation of the offshore grid are investigated. Our findings show that the nominal-frequency high-voltage option is the more suitable, as low-frequency does not bring any advantage and low-voltage would results in higher costs. The second analysis is related to the differences in operating the system with low- or zero-inertia; different dynamic studies are performed for each configuration to identify proper control actions and their stability properties. Comparing the outcomes of the simulations, we observed that voltage and frequency oscillations are better damped in the zero-inertia system; however, the risk of propagating offshore faults in the connected onshore grids is mitigated with the inclusion of the synchronous condensers. Lastly, a comparison of ElectroMagnetic Transient (EMT) and phasor-mode (also known as RMS) models is presented, in order to understand their appropriateness of simulating low- and zero- inertia systems. The results show that phasor approximation modelling can be used, as long as eigen-frequencies in power network are well damped.

eess.SY↗

HVDC Loss Factors in the Nordic Power Market

In the Nordic countries (Sweden, Norway, Finland and Denmark), many interconnectors are formed by long High-Voltage Direct-Current (HVDC) lines. Every year, the operation of such interconnectors costs millions of Euros to Transmission System Operators (TSOs) due to the high amount of losses that are not considered while clearing the market. To counteract this problem, Nordic TSOs (Svenska kraftnät - Sweden, Statnett - Norway, Fingrid - Finland, Energinet - Denmark) have proposed to introduce linear HVDC loss factors in the market clearing algorithm. The assessment of such a measure requires a detailed model of the system under investigation. In this paper we develop and introduce a detailed market model of the Nordic countries and we analyze the impact of different loss factor formulations. We show that linear loss factors penalize one HVDC line over the other, and this can jeopardize revenues of merchant HVDC lines. In this regard, we propose piecewise-linear loss factors: a simple to implement but highly effective solution. Moreover, we demonstrate how the introduction of only HVDC loss factors is a partial solution, since it disproportionately increases the AC losses. Our results show that the inclusion of AC loss factors can eliminate this problem.

math.OC↗

Efficient Creation of Datasets for Data-Driven Power System Applications

Advances in data-driven methods have sparked renewed interest for applications in power systems. Creating datasets for successful application of these methods has proven to be very challenging, especially when considering power system security. This paper proposes a computationally efficient method to create datasets of secure and insecure operating points. We propose an infeasibility certificate based on separating hyperplanes that can a-priori characterize large parts of the input space as insecure, thus significantly reducing both computation time and problem size. Our method can handle an order of magnitude more control variables and creates balanced datasets of secure and insecure operating points, which is essential for data-driven applications. While we focus on N-1 security and uncertainty, our method can extend to dynamic security. For PGLib-OPF networks up to 500 buses and up to 125 control variables, we demonstrate drastic reductions in unclassified input space volumes and computation time, create balanced datasets, and evaluate an illustrative data-driven application.

eess.SY↗

Inexact Convex Relaxations for AC Optimal Power Flow: Towards AC Feasibility

Convex relaxations of AC optimal power flow (AC-OPF) problems have attracted significant interest as in several instances they provably yield the global optimum to the original non-convex problem. If, however, the relaxation is inexact, the obtained solution is not AC-feasible. The quality of the obtained solution is essential for several practical applications of AC-OPF, but detailed analyses are lacking in existing literature. This paper aims to cover this gap. We provide an in-depth investigation of the solution characteristics when convex relaxations are inexact, we assess the most promising AC feasibility recovery methods for large-scale systems, and we propose two new metrics that lead to a better understanding of the quality of the identified solutions. We perform a comprehensive assessment on 96 different test cases, ranging from 14 to 3120 buses, and we show the following: (i) Despite an optimality gap of less than 1%, several test cases still exhibit substantial distances to both AC feasibility and local optimality and the newly proposed metrics characterize these deviations. (ii) Penalization methods fail to recover an AC-feasible solution in 15 out of 45 cases, and using the proposed metrics, we show that most failed test instances exhibit substantial distances to both AC-feasibility and local optimality. For failed test instances with small distances, we show how our proposed metrics inform a fine-tuning of penalty weights to obtain AC-feasible solutions. (iii) The computational benefits of warm-starting non-convex solvers have significant variation, but a computational speedup exists in over 75% of the cases.

math.OC↗

Zero-inertia Systems: Sufficient Conditions for Phasor Modeling

Time-domain simulations are a critical tool for power system operators. Depending on the instability mechanism under consideration and the system characteristics, such as the time constants of controllers, either phasor or Electro-Magnetic Transient (EMT) models should be employed. On the one hand, EMT models provide a detailed-modeling of the system dynamics, thus increase the reliability of stability analysis; on the other end, using these models increase the computational times of simulations, slowing down the security assessment process. To decrease computational time, system operators could resort to phasor-mode simulations for a (hopefully large) subset of disturbances. This paper investigates the appropriateness of phasor-approximation models on simulating events related to power supply and balance stability in zero-inertia systems. First, the stability boundaries, which each model is able to identify, are analyzed; then sufficient conditions for control parameters are derived, which allow using phasor-approximation models to monitor power sharing among grid-forming converter-based resources. Time-domain simulations are performed in PowerFactory DigSilent to verify the results.

eess.SY↗