Searcharxiv⌕ Search

arXiv subjects

Spyros Tzamarias

Publications and source records attributed to Spyros Tzamarias.

6 recordsLinked to original sources

Design, simulation and performance of the resistive-anode PICOSEC Micromegas detector

The PICOSEC Micromegas detector is a Micro-Pattern Gaseous Detector concept developed to achieve tens of picosecond timing resolution for charged particle detection by combining a Cherenkov radiator with a two-stage Micromegas amplification structure. To improve operational robustness, a resistive anode has been implemented using a DLC layer deposited on a Kapton substrate. While this design enhances detector stability, the resistive layer may influence rate capability, signal formation, and detector capacitance, altering timing performance. This work presents a comprehensive study of a resistive design, including an analytical model and finite-element simulations to quantify rate-dependent gain reduction due to ohmic voltage drop on the resistive layer. An analytical solution for the voltage across a finite-size resistive layer is derived, and a numerical model is developed to evaluate gain suppression under intense particle fluxes. The impact of the resistive layer on signal formation is investigated using time-dependent weighting fields and the Garfield++ simulation framework. The contribution of signal components induced by the resistive layer is quantified, and preservation of the signal leading edge is found for surface resistivities above 100 kohm per square. Single-channel resistive-anode prototypes were designed, constructed, and experimentally characterized. Laboratory measurements using single photoelectrons and power spectral density analysis show the predicted reduction in signal amplitude while preserving the leading edge. Muon beam tests with CsI and DLC photocathodes demonstrate a time resolution of 11.5 ps for CsI, comparable to 11.9 ps for the metallic-anode device, showing the suitability of the resistive design for precision timing applications.

physics.ins-det↗

Status of the Proton EDM Experiment (pEDM)

The Proton EDM Experiment (pEDM) is the first direct search for the proton electric dipole moment (EDM) with the aim of being the first experiment to probe the Standard Model (SM) prediction of any particle EDM. Phase-I of pEDM will achieve $10^{-29} e\cdot$cm, improving current indirect limits by four orders of magnitude. This will establish a new standard of precision in nucleon EDM searches and offer a unique sensitivity to better understand the Strong CP problem. The experiment is ideally positioned to explore physics beyond the Standard Model (BSM), with sensitivity to axionic dark matter via the signal of an oscillating proton EDM and across a wide mass range of BSM models from $\mathcal{O}(1\text{GeV})$ to $\mathcal{O}(10^3\text{TeV})$. Utilizing the frozen-spin technique in a highly symmetric storage ring that leverages existing infrastructure at Brookhaven National Laboratory (BNL), pEDM builds upon the technological foundation and experimental expertise of the highly successful Muon $g$$-$$2$ Experiments. With significant R\&D and prototyping already underway, pEDM is preparing a conceptual design report (CDR) to offer a cost-effective, high-impact path to discovering new sources of CP violation and advancing our understanding of fundamental physics. It will play a vital role in complementing the physics goals of the next-generation collider while simultaneously contributing to sustaining particle physics research and training early-career researchers during gaps between major collider operations.

hep-ex↗

A large area 100 channel Picosec Micromegas detector with sub 20 ps time resolution

The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to achieve time resolution below 25 ps. One of the crucial aspects in the development of the precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm$^2$ suffered from degraded timing resolution due to the non-uniformity of the preamplification gap. A new 100 cm$^2$ detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over measured pads and a time resolution below 25 ps. More recent measurements with a new thinner drift gap detector module and newly developed RF pulse amplifiers show that the resolution can be enhanced to a level of 17~ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

physics.ins-det↗

Towards robust PICOSEC Micromegas precise timing detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel non-resistive PICOSEC MM prototype with 10x10 cm^2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects; i.e. integration of resistive MM and carbon-based photocathodes; while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below 20 ps for an individual pad obtained with the 10x10 cm^2 area resistive PICOSEC MM of 20 MOhm/sq showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B4C) photocathode presented a time resolution below 35 ps; opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution.

physics.ins-det↗

Performance of the RF-detectors of the Astroneu Array

Since 2014, the University Campus of the Hellenic Open University (HOU) hosts the Astroneu array which is dedicated to the detection of Extensive Air Showers (EAS) induced by high energy Cosmic Rays (CR). The Astroneu array incorporates 9 large particle scintillation detectors and 6 antennas sensitive in the Radio Frequency (RF) range 1-200 MHz. The detectors are adjusted in three autonomous stations operating in an environment with strong electromagnetic background. As shown by previous studies, EAS radio detection in such environments is possible using innovative noise rejection methods, as well as advanced analysis techniques. In this work, we present the analysis of the collected radio data corresponding to an operational period of approximately four years. We present the performance of the Astroneu radio array in reconstructing the EAS axis direction using different RF detector geometrical layouts and a technique for the estimation of the shower core by comparing simulation and experimental data. Moreover, we measure the relative amplitudes of the two mechanisms that give rise to RF emission (Askaryan effect and Geomagnetic emission) and show that they are in good agreement with previous studies as well as with the simulation predictions.

astro-ph.IM↗

The storage ring proton EDM experiment

We describe a proposal to search for an intrinsic electric dipole moment (EDM) of the proton with a sensitivity of \targetsens, based on the vertical rotation of the polarization of a stored proton beam. The New Physics reach is of order $10^~3$TeV mass scale. Observation of the proton EDM provides the best probe of CP-violation in the Higgs sector, at a level of sensitivity that may be inaccessible to electron-EDM experiments. The improvement in the sensitivity to $θ_{QCD}$, a parameter crucial in axion and axion dark matter physics, is about three orders of magnitude.

hep-ph↗