SearcharxivSearch

arXiv subjects

Stefan Walser

Publications and source records attributed to Stefan Walser.

7 recordsLinked to original sources

Properties of quantum emitters in different hBN sample types particularly suited for nanophotonic integration

Single photon emitters in two-dimensional (2D) hexagonal boron nitride (hBN) are promising solid-state quantum emitters for photonic applications and quantum networks. Despite their favorable properties, much is still unknown about their characteristics and their atomic origin. We focus on two different kinds of hBN samples that particularly lend themselves for integration with nanophotonic devices, multilayer nanoflakes produced by liquid phase exfoliation (LPE) and a layer-engineered sample from hBN grown by chemical vapour deposition (CVD). We investigate their inherent defects and fit their emission properties to computationally simulated optical properties of likely carbon-related defects. Thereby we compare and elucidate the properties in different sample types particularly suited for photonic quantum networks and narrow down the origin of emitters found in these samples. Our work is thus an important step towards harnessing the full potential of single photon emitters in hBN.

quant-ph

Strategies for implementing quantum error correction in molecular rotation

The rotation of trapped molecules offers a promising platform for quantum technologies and quantum information processing. In parallel, quantum error correction codes that can protect quantum information encoded in rotational states of a single molecule have been developed. These codes are currently an abstract concept, as no implementation strategy is yet known. Here, we present a step towards experimental implementation of one family of such codes, namely absorption-emission codes. We first construct architecture-agnostic check and correction operators. These operators are then decomposed into elements of the quantum logic spectroscopy toolbox that is available for molecular ions. We then describe and analyze a measurement-based sequential as well as an autonomous implementation strategy in the presence of thermal background radiation, a major noise source for rotation in polar molecules. The presented strategies and methods might enable robust sensing or even fault-tolerant quantum computing using the rotation of individual molecules.

quant-ph

Photodissociation spectra of single trapped CaOH+ molecular ions

Molecular ions that are generated by chemical reactions with trapped atomic ions can serve as an accessible testbed for developing molecular quantum technologies. On the other hand, they are also a hindrance to scaling up quantum computers based on atomic ions as unavoidable reactions with background gas destroy the information carriers. Here, we investigate the single- and two-photon dissociation processes of single $\text{CaOH}^+$ molecular ions co-trapped in $\text{Ca}^+$ ion crystals using a femtosecond laser system. We report the photodissociation cross section spectra of $\text{CaOH}^+$ for single-photon processes at $λ=$245 - 275$\,$nm and for two-photon processes at $λ=$500 - 540$\,$nm. Measurements are interpreted with quantum-chemical calculations, which predict the photodissociation threshold for $\text{CaOH}^+\to \text{Ca}^++\text{OH}$ at 265$\,$nm. This result can serve as a basis for dissociation-based spectroscopy for studying the internal structure of $\text{CaOH}^+$. The result also gives a prescription for recycling $\text{Ca}^+$ ions in large-scale trapped $\text{Ca}^+$ quantum experiments from undesired $\text{CaOH}^+$ ions formed in the presence of background water vapor.

physics.atom-ph

Non-invasive urinary bladder volume estimation with artefact-suppressed bio-impedance measurements

Urine output is a vital parameter to gauge kidney health. Current monitoring methods include manually written records, invasive urinary catheterization or ultrasound measurements performed by highly skilled personnel. Catheterization bears high risks of infection while intermittent ultrasound measures and manual recording are time consuming and might miss early signs of kidney malfunction. Bioimpedance (BI) measurements may serve as a non-invasive alternative for measuring urine volume in vivo. However, limited robustness have prevented its clinical translation. Here, a deep learning-based algorithm is presented that processes the local BI of the lower abdomen and suppresses artefacts to measure the bladder volume quantitatively, non-invasively and without the continuous need for additional personnel. A tetrapolar BI wearable system called ANUVIS was used to collect continuous bladder volume data from three healthy subjects to demonstrate feasibility of operation, while clinical gold standards of urodynamic (n=6) and uroflowmetry tests (n=8) provided the ground truth. Optimized location for electrode placement and a model for the change in BI with changing bladder volume is deduced. The average error for full bladder volume estimation and for residual volume estimation was -29 +/-87.6 ml, thus, comparable to commercial portable ultrasound devices (Bland Altman analysis showed a bias of -5.2 ml with LoA between 119.7 ml to -130.1 ml), while providing the additional benefit of hands-free, non-invasive, and continuous bladder volume estimation. The combination of the wearable BI sensor node and the presented algorithm provides an attractive alternative to current standard of care with potential benefits in providing insights into kidney function.

eess.SP

Active Interaction Force Control for Contact-Based Inspection with a Fully Actuated Aerial Vehicle

This paper presents and validates active interaction force control and planning for fully actuated and omnidirectional aerial manipulation platforms, with the goal of aerial contact inspection in unstructured environments. We present a variable axis-selective impedance control which integrates direct force control for intentional interaction, using feedback from an on-board force sensor. The control approach aims to reject disturbances in free flight, while handling unintentional interaction, and actively controlling desired interaction forces. A fully actuated and omnidirectional tilt-rotor aerial system is used to show capabilities of the control and planning methods. Experiments demonstrate disturbance rejection, push-and-slide interaction, and force controlled interaction in different flight orientations. The system is validated as a tool for non-destructive testing of concrete infrastructure, and statistical results of

cs.RO

Wavelength-scale errors in optical localization due to spin-orbit coupling of light

The precise determination of the position of point-like emitters and scatterers using far-field optical imaging techniques is of utmost importance for a wide range of applications in medicine, biology, astronomy, and physics. Although the optical wavelength sets a fundamental limit to the image resolution of unknown objects, the position of an individual emitter can in principle be estimated from the image with arbitrary precision. This is used, e.g., in stars' position determination and in optical super-resolution microscopy. Furthermore, precise position determination is an experimental prerequisite for the manipulation and measurement of individual quantum systems, such as atoms, ions, and solid state-based quantum emitters. Here we demonstrate that spin-orbit coupling of light in the emission of elliptically polarized emitters can lead to systematic, wavelength-scale errors in the estimate of the emitter's position. Imaging a single trapped atom as well as a single sub-wavelength-diameter gold nanoparticle, we demonstrate a shift between the emitters' measured and actual positions which is comparable to the optical wavelength. Remarkably, for certain settings, the expected shift can become arbitrarily large. Beyond their relevance for optical imaging techniques, our findings apply to the localization of objects using any type of wave that carries orbital angular momentum relative to the emitter's position with a component orthogonal to the direction of observation.

quant-ph

An Omnidirectional Aerial Manipulation Platform for Contact-Based Inspection

This paper presents an omnidirectional aerial manipulation platform for robust and responsive interaction with unstructured environments, toward the goal of contact-based inspection. The fully actuated tilt-rotor aerial system is equipped with a rigidly mounted end-effector, and is able to exert a 6 degree of freedom force and torque, decoupling the system's translational and rotational dynamics, and enabling precise interaction with the environment while maintaining stability. An impedance controller with selective apparent inertia is formulated to permit compliance in certain degrees of freedom while achieving precise trajectory tracking and disturbance rejection in others. Experiments demonstrate disturbance rejection, push-and-slide interaction, and on-board state estimation with depth servoing to interact with local surfaces. The system is also validated as a tool for contact-based non-destructive testing of concrete infrastructure.

cs.RO