SearcharxivSearch

arXiv subjects

Stefano Piacentini

Publications and source records attributed to Stefano Piacentini.

7 recordsLinked to original sources

EXPO: a quantum leap in fast, wide-band X-ray polarimetry for astrophysics

The Enhanced X-ray Polarimetry Observatory (EXPO) is a mission concept proposed to ESA as an M8 candidate, with a prospective launch in 2041. Building on the scientific success of IXPE, EXPO is designed to overcome its two main limitations, the narrow 2-8 keV energy band and the very slow repointing time, and to enable new scientific capabilities. A wide energy band and fast repointing are essential for investigating the hard X-ray emission of magnetars and black-hole binaries, particle acceleration in supernova remnants and pulsar-wind nebulae, radiative transfer in highly magnetized plasmas, X-ray reflection in accretion flows and active galactic nuclei, and the prompt and afterglow emission of gamma-ray bursts and magnetar flares. EXPO comprises five focusing X-ray telescopes and gas photoelectric polarimeters based on the Timepix ASIC family with InGrid amplification, enabling three-dimensional track imaging and operation in the 2-35 keV band through optimized low- and medium-energy detector configurations. The mirror modules use proven electroformed nickel technology with Au-C coatings and an XMM-like focal length of 7.5 m. The polarimeters are complemented by a coded-mask Wide Field Instrument (WFI), derived from SVOM/ECLAIRs for continuous monitoring of a 2 sr field of view; a Spectral Imaging Camera (SIC), based on stacked CMOS and CdTe detectors for broadband imaging spectroscopy and accurate spectro-polarimetric decomposition; and an Instrument Control Unit (ICU) for payload management, onboard WFI image reconstruction, transient identification, and autonomous spacecraft repointing requests. These capabilities extend X-ray polarimetry into the hard X-ray domain and open a new observational window on fast transients, time-domain astrophysics, and multi-messenger astronomy.

astro-ph.IM

Modeling the light response of an optically readout GEM based TPC for the CYGNO experiment

The use of gaseous Time Projection Chambers enables the detection and the detailed study of rare events due to particles interactions with the atoms of the gas with energy releases as low as a few keV. Due to this capability, these instruments are being developed for applications in the field of astroparticle physics, such as the study of dark matter and neutrinos. To readout events occurring in the sensitive volume with a high granularity, the CYGNO collaboration is developing a solution where the light generated during the avalanche processes occurring in a multiplication stage based on Gas Electron Multiplier (GEM) is read out by optical sensors with very high sensitivity and spatial resolution. To achieve a high light output, gas gain values of the order of $10^5\text{-}10^6$ are needed. Experimentally, a dependence of the detector response on the spatial density of the charge collected in the GEM holes has been observed, indicating a gain-reduction effect likely caused by space-charge buildup within the multiplication channels. This paper presents data collected with a prototype featuring a sensitive volume of about two liters, together with a model developed by the collaboration to describe and predict the gain dependence on charge density. A comparison with experimental data shows that the model accurately reproduces the gain behaviour over nearly one order of magnitude, with a percent-level precision.

physics.ins-det

Bayesian network 3D event reconstruction in the Cygno optical TPC for dark matter direct detection

The CYGNO experiment is developing a high-resolution gaseous Time Projection Chamber with optical readout for directional dark matter searches. The detector uses a helium-tetrafluoromethane (He:CF$_4$ 60:40) gas mixture at atmospheric pressure and a triple Gas Electron Multiplier amplification stage, coupled with a scientific camera for high-resolution 2D imaging and fast photomultipliers for time-resolved scintillation light detection. This setup enables 3D event reconstruction: photomultipliers signals provide depth information, while the camera delivers high-precision transverse resolution. In this work, we present a Bayesian Network-based algorithm designed to reconstruct the events using only the photomultipliers signals, yielding a full 3D description of the particle trajectories. The algorithm models the light collection process probabilistically and estimates spatial and intensity parameters on the Gas Electron Multiplier plane, where light emission occurs. It is implemented within the Bayesian Analysis Toolkit and uses Markov Chain Monte Carlo sampling for posterior inference. Validation using data from the CYGNO LIME prototype shows accurate reconstruction of localized and extended tracks. Results demonstrate that the Bayesian approach enables robust 3D description and, when combined with camera data, further improves the precision of track reconstruction. This methodology represents a significant step forward in directional dark matter detection, enhancing the identification of nuclear recoil tracks with high spatial resolution.

physics.ins-det

LIME -- a gas TPC prototype for directional Dark Matter search for the CYGNO experiment

The CYGNO experiment aims at the development of a large gaseous TPC with GEM-based amplification and an optical readout by means of PMTs and scientific CMOS cameras for 3D tracking down to O(keV) energies, for the directional detection of rare events such as low mass Dark Matter and solar neutrino interactions. The largest prototype built so far towards the realisation of the CYGNO experiment demonstrator is the 50 L active volume LIME, with 4 PMTs and a single sCMOS imaging a 33$\times$33 cm\textsuperscript{2} area for 50 cm drift, that has been installed in underground Laboratori Nazionali del Gran Sasso in February 2022. We will illustrate LIME performances as evaluated overground in Laboratori Nazionali di Frascati by means of radioactive X-ray sources, and in particular the detector stability, energy response and energy resolution. We will discuss the MC simulation developed to reproduce the detector response and show the comparison with actual data. We will furthermore examine the background simulation worked out for LIME underground data taking and illustrate the foreseen expected measurement and results in terms of natural and materials intrinsic radioactivity characterisation and measurement of the LNGS underground natural neutron flux. The results that will be obtained by underground LIME installation will be paramount in the optimisation of the CYGNO demonstrator, since this is foreseen to be composed by multiple modules with the same LIME dimensions and characteristics.

physics.ins-det

The CYGNO Experiment

The search for a novel technology able to detect and reconstruct nuclear and electron recoil events with the energy of a few keV has become more and more important now that large regions of high-mass dark matter (DM) candidates have been excluded. Moreover, a detector sensitive to incoming particle direction will be crucial in the case of DM discovery to open the possibility of studying its properties. Gaseous time projection chambers (TPC) with optical readout are very promising detectors combining the detailed event information provided by the TPC technique with the high sensitivity and granularity of latest-generation scientific light sensors. The CYGNO experiment (a CYGNus module with Optical readout) aims to exploit the optical readout approach of multiple-GEM structures in large volume TPCs for the study of rare events as interactions of low-mass DM or solar neutrinos. The combined use of high-granularity sCMOS cameras and fast light sensors allows the reconstruction of the 3D direction of the tracks, offering good energy resolution and very high sensitivity in the few keV energy range, together with a very good particle identification useful for distinguishing nuclear recoils from electronic recoils. This experiment is part of the CYGNUS proto-collaboration, which aims at constructing a network of underground observatories for directional DM search. A one cubic meter demonstrator is expected to be built in 2022/23 aiming at a larger scale apparatus (30 m$^3$--100 m$^3$) at a later stage.

physics.ins-det

Migdal effect and photon Bremsstrahlung: improving the sensitivity to light dark matter of liquid argon experiments

The search for dark matter weakly interacting massive particles with noble liquids has probed masses down and below a GeV/c^2. The ultimate limit is represented by the experimental threshold on the energy transfer to the nuclear recoil. Currently, the experimental sensitivity has reached a threshold equivalent to a few ionization electrons. In these conditions, the contribution of a Bremsstrahlung photon or a so-called Migdal electron due to the sudden acceleration of a nucleus after a collision might be sizable. In the present work, we use a Bayesian approach to study how these effects can be exploited in experiments based on liquid argon detectors. In particular, taking inspiration from the DarkSide-50 public spectra, we develop a simulated experiment to show how the Migdal electron and the Bremsstrahlung photon allow to push the experimental sensitivity down to masses of 0.1 GeV/c^2, extending the search region for dark matter particles of previous results. For these masses we estimate the effect of the Earth shielding that, for strongly interacting dark matter, makes any detector blind. Finally, we show how the sensitivity scales for higher exposure.

hep-ph

Annual modulations from secular variations: not relaxing DAMA?

In a recent paper [arXiv:2002.00459], Buttazzo et al. show how the annually modulated rate of the DAMA experiments can be possibly interpreted as an artefact due to the interplay between a time-dependent background and the method to account for it. In this work, we compare this hypothesis against the sinusoidal dark matter signal as proposed by the DAMA collaboration. We produce in a Bayesian approach a quantitative comparison of how much the experimental observations are in support of each hypothesis. Our conclusions are that the odds against the hypothesis of a time varying background being responsible for the annual modulation are decreased by a Bayes factor larger than 10^8 after considering the public available data of the DAMA/NaI and DAMA/LIBRA experiments. In this work we also elaborate on general aspects of the analysis procedure. Indeed, in order to optimise the background subtraction procedure, the DAMA collaboration only considers data-taking cycles with a duration of roughly one year. We argue that any data-taking cycle is informative, and we propose a procedure to include this effect, as well as the possibility to include a slowly varying component for the background.

hep-ex