Searcharxiv⌕ Search

arXiv subjects

Steffen Görner

Publications and source records attributed to Steffen Görner.

2 recordsLinked to original sources

In Vivo Wideband MR Elastography for Assessing Age-Related Viscoelastic Changes of the Human Brain

Magnetic Resonance Elastography (MRE) noninvasively maps brain biomechanics and is highly sensitive to alterations associated with aging and neurodegenerative disease. Most implementations use a single frequency or a narrow frequency band, limiting the analysis of frequency-dependent viscoelastic parameters. We developed a dual-actuator wideband MRE (5-50 Hz) protocol and acquired wavefields at 13 frequencies in 24 healthy adults (young: 23-39 years; older: 50-63 years). Shear wave speed (SWS) maps were generated as a proxy for stiffness, and SWS dispersion was modeled using Newtonian, Kelvin-Voigt, and power-law rheological models. Whole-brain stiffness declined with age, with the strongest effect observed at low frequencies (5-16 Hz: -0.24%/year; p=0.019) compared with mid (20-35 Hz: -0.12%/year; p=0.030) and high frequencies (40-50 Hz: -0.10%/year; p=0.165). Compared to older brains, younger adults showed 14.3% higher baseline stiffness in the power-law model (p=0.001) and 8.5-9.0% higher viscosity according to the Newtonian and Kelvin-Voigt model (p<0.05). White and cortical gray matter exhibited similar age-related decreases, while deep gray matter showed an increase in the power-law exponent (+0.001/year; p=0.036), suggesting a transition toward more fluid-like properties associated with aging. Wideband MRE revealed frequency-dependent and region-specific biomechanical alterations with aging, with the strongest effects observed at low frequencies. Extending brain MRE into the low frequency regime potentially enhances sensitivity to solid-fluid interactions. Therefore, low frequency MRE may serve as an early biomechanical marker of microstructural brain changes due to aging and neurodegeneration.

physics.med-ph↗

Liquid-liver phantom: mimicking the viscoelastic dispersion of human liver for elastography in ultrasound and MRI

Different clinical elastography devices show different liver-stiffness values in the same subject, hindering comparison of values and establishment of system-independent thresholds for disease detection. Therefore, authorities request standardized phantoms that address the viscosity-related dispersion of stiffness over frequency. A linear polymerized polyacrylamide phantom (PAAm) was calibrated to the viscoelastic properties of healthy human liver in vivo. Shear-wave speed as a surrogate of stiffness was quantified between 5 Hz and 3000 Hz frequency-range by shear rheometry, ultrasound-based time-harmonic elastography, clinical MR elastography (MRE), and tabletop MRE. Imaging parameters for ultrasound were close to those of liver in vivo. Reproducibility, aging behavior and temperature dependency were assessed and fulfilled requirements for quantitative elastography. In addition, the phantom was used to characterize the frequency bandwidth of shear-wave speed of several clinical elastography methods. The liquid-liver phantom has favorable properties for standardization and development of liver elastography: first, it can be used across clinical and experimental elastography devices in ultrasound and MRI. Second, being a liquid, it can easily be adapted in size and shape to specific technical requirements, and by adding inclusions and scatterers. Finally, since the phantom is based on non-crosslinked linear PAA constituents, it is easy to produce, indicating potential widespread use among researchers and vendors to standardize liver-stiffness measurements.

physics.bio-ph↗