SearcharxivSearch

arXiv subjects

Steffen Mueller

Publications and source records attributed to Steffen Mueller.

3 recordsLinked to original sources

A Kalman Filter-Based Disturbance Observer for Steer-by-Wire Systems

Steer-by-Wire systems replace mechanical linkages, which provide benefits like weight reduction, design flexibility, and compatibility with autonomous driving. However, they are susceptible to high-frequency disturbances from unintentional driver torque, known as driver impedance, which can degrade steering performance. Existing approaches either rely on direct torque sensors, which are costly and impractical, or lack the temporal resolution to capture rapid, high-frequency driver-induced disturbances. We address this limitation by designing a Kalman filter-based disturbance observer that estimates high-frequency driver torque using only motor state measurements. We model the drivers passive torque as an extended state using a PT1-lag approximation and integrate it into both linear and nonlinear Steer-by-Wire system models. In this paper, we present the design, implementation and simulation of this disturbance observer with an evaluation of different Kalman filter variants. Our findings indicate that the proposed disturbance observer accurately reconstructs driver-induced disturbances with only minimal delay 14ms. We show that a nonlinear extended Kalman Filter outperforms its linear counterpart in handling frictional nonlinearities, improving estimation during transitions from static to dynamic friction. Given the study's methodology, it was unavoidable to rely on simulation-based validation rather than real-world experimentation. Further studies are needed to investigate the robustness of the observers under real-world driving conditions.

cs.RO

Design, Implementation and First Measurements with the Medipix Neutron Camera in CMS

The Medipix detector is the first device dedicated to measuring mixed-field radiation in the CMS cavern and able to distinguish between different particle types. Medipix2-MXR chips bump bonded to silicon sensors with various neutron conversion layers developed by the IEAP CTU in Prague were successfully installed for the 2008 LHC start-up in the CMS experimental and services caverns to measure the flux of various particle types, in particular neutrons. They have operated almost continuously during the 2010 run period, and the results shown here are from the proton run between the beginning of July and the end of October 2010. Clear signals are seen and different particle types have been observed during regular LHC luminosity running, and an agreement in the measured flux rate is found with the simulations. These initial results are promising, and indicate that these devices have the potential for further and future LHC and high energy physics applications as radiation monitoring devices for mixed field environments, including neutron flux monitoring. Further extensions are foreseen in the near future to increase the performance of the detector and its coverage for monitoring in CMS.

physics.ins-det

Radiation hardness of diamond and silicon sensors compared

The radiation hardness of silicon charged particle sensors is compared with single crystal and polycrystalline diamond sensors, both experimentally and theoretically. It is shown that for Si- and C-sensors, the NIEL hypothesis, which states that the signal loss is proportional to the Non-Ionizing Energy Loss, is a good approximation to the present data. At incident proton and neutron energies well above 0.1 GeV the radiation damage is dominated by the inelastic cross section, while at non-relativistic energies the elastic cross section prevails. The smaller inelastic nucleon-Carbon cross section and the light nuclear fragments imply that at high energies diamond is an order of magnitude more radiation hard than silicon, while at energies below 0.1 GeV the difference becomes significantly smaller.

physics.ins-det