Searcharxiv⌕ Search

arXiv subjects

Stephan Schlamminger

Publications and source records attributed to Stephan Schlamminger.

25 records · Page 2Linked to original sources

A nonlinearity in permanent-magnet systems used in watt balances

Watt balances are used to measure the Planck constant and will be used in the future to realize mass at the kilogram level. They increasingly rely on permanent magnet systems to generate the magnetic flux. It has been known that the weighing current might effect the magnetization state of the permanent magnetic system used in these systems causing a systematic bias that can lead to an error in the result if not accounted for. In this article a simple model explaining the effect of the weighing current on the yoke of the magnet is developed. This model leads to a nonlinear dependence of the magnetic flux density in the gap that is proportional to the squared value of the coil current. The effect arises from changing the reluctance of the yoke by the additional field produced by the coil. Our analysis shows that the effect depends on the width of the air gap, the magnetic flux density in the air gap, and the $BH$ curve of the yoke material. Suggestions to reduce the nonlinear effect are discussed.

physics.class-ph↗

Determination of the Planck constant using a watt balance with a superconducting magnet system at the National Institute of Standards and Technology

For the past two years, measurements have been performed with a watt balance at the National Institute of Standards and Technology (NIST) to determine the Planck constant. A detailed analysis of these measurements and their uncertainties has led to the value $h=6.626\,069\,79(30)\times 10^{-34}\,$J$\,$s. The relative standard uncertainty is $ 45\times 10^{-9}$. This result is $141\times 10^{-9}$ fractionally higher than $h_{90}$. Here $h_{90}$ is the conventional value of the Planck constant given by $h_{90}\equiv 4 /( K_{\mathrm{J-90}}^2R_{\mathrm{K-90}})$, where $K_{\mathrm{J-90}}$ and $R_{\mathrm{K-90}}$ denote the conventional values of the Josephson and von Klitzing constants, respectively.

physics.class-ph↗

Picoradian deflection measurement with an interferometric quasi-autocollimator using weak value amplification

We present an "interferometric quasi-autocollimator" that employs weak value amplification to measure angular deflections of a target mirror. The device has been designed to be insensitive to all translations of the target. We present a conceptual explanation of the amplification effect used by the device. An implementation of the device demonstrates sensitivities better than 10 picoradians per root hertz between 10 and 200 hertz.

physics.ins-det↗

Removal of zero-point drift from AB data and the statistical cost

Often the result of a scientific experiment is given by the difference of measurements in two configurations, denoted by A and B. Since the measurements are not obtained simultaneously, drift of the zero-point can bias the result. In practice measurement patterns are used to minimize this bias. The time sequence AB followed by BA, for example, would cancel a linear drift in the average difference A-B. We propose taking data with an alternating series ABAB.., and removing drift with a post-hoc analysis. We present an analysis method that removes bias from the result for drift up to polynomial order p. A statistical cost function c(N) is introduced to compare the uncertainty in the end result with that from using a raw data average. For a data set size N>30 the statistical cost is negligible. For N<30 the cost is plotted as a function of N and filter order p and the trade off between the size of the data set and p is discussed.

physics.data-an↗

Indirect Evidence for Lévy Walks in Squeeze Film Damping

Molecular flow gas damping of mechanical motion in confined geometries, and its associated noise, is important in a variety of fields, including precision measurement, gravitational wave detection, and MEMS devices. We used two torsion balance instruments to measure the strength and distance-dependence of `squeeze film' damping. Measured quality factors derived from free decay of oscillation are consistent with gas particle superdiffusion in Lévy walks and inconsistent with those expected from traditional Gaussian random walk particle motion. The distance-dependence of squeeze film damping observed in our experiments is in agreement with a parameter-free Monte Carlo simulation. The squeeze film damping of the motion of a plate suspended a distance d away from a parallel surface scales with a fractional power between 1/d and 1/d^2.

gr-qc↗

Temporal Extent of Surface Potentials between Closely Spaced Metals

Variations in the electrostatic surface potential between the proof mass and electrode housing in the space-based gravitational wave mission LISA is one of the largest contributors of noise at frequencies below a few mHz. Torsion balances provide an ideal testbed for investigating these effects in conditions emulative of LISA. Our apparatus consists of a Au coated Cu plate brought near a Au coated Si plate pendulum suspended from a thin W wire. We have measured a white noise level of $30, \uVhz$ above approximately 0.1, mHz, rising at lower frequencies, for the surface potential variations between these two closely spaced metals.

gr-qc↗

Outgassing, Temperature Gradients and the Radiometer Effect in LISA: A Torsion Pendulum Investigation

Thermal modeling of the LISA gravitational reference sensor (GRS) includes such effects as outgassing from the proof mass and its housing and the radiometer effect. Experimental data in conditions emulating the LISA GRS are required to confidently predict the GRS performance. Outgassing and the radiometer effect are similar in characteristics and are difficult to decouple experimentally. The design of our torsion balance allows us to investigate differential radiation pressure, the radiometer effect, and outgassing on closely separated conducting surfaces with high sensitivity. A thermally controlled split copper plate is brought near a freely hanging plate-torsion pendulum.We have varied the temperature on each half of the copper plate and have measured the resulting forces on the pendulum. We have determined that to first order the current GRS model for the radiometer effect, outgassing, and radiation pressure are mostly consistent with our torsion balance measurements and therefore these thermal effects do not appear to be a large hindrance to the LISA noise budget. However, there remain discrepancies between the predicted dependence of these effects on the temperature of our apparatus.

gr-qc↗