Evaluation of Silicon-Based Photon-Counting CT for Coronary Stenosis Quantification with Realistic Coronary Artery Phantoms

Objective: To quantify the impact of high-resolution deep silicon photon-counting CT (dSi-PCCT) on coronary stenosis quantification in anatomically realistic calcified coronary artery phantoms using Micro-CT as ground truth. Methods: Twelve vessel sections representing four calcification geometries (Type I-IV) and three luminal iodine concentrations (10, 15, and 20 mg/mL) were scanned under static conditions using energy-integrating detector CT (EID-CT), dSi-PCCT, and Micro-CT. Images were registered to Micro-CT and segmented using an automated threshold-based pipeline. The primary analysis compared longitudinal profiles of Micro-CT-referenced percent area stenosis and segmented vessel area. A secondary analysis evaluated ellipse-derived percent area stenosis and percent vessel-area deviation at the maximum-calcification cross-section. Results: dSi-PCCT reduced whole-profile mean absolute error in Micro-CT-referenced percent area stenosis from 3.10% with EID-CT to 1.62% (p=0.027) and reduced segmented vessel-area error from 0.55 to 0.31 mm2 (p=0.001). In the secondary analysis, absolute deviations in ellipse-derived percent area stenosis ranged from 0.1% to 6.5% for dSi-PCCT and from 0.8% to 24.2% for EID-CT (p<0.001). Mean absolute differences in percent vessel-area deviation from Micro-CT were also lower with dSi-PCCT than with EID-CT (15.0% vs 26.6%, p<0.001). Conclusion: Under static, resolution-optimized conditions, dSi-PCCT improved task-based coronary stenosis quantification and vessel delineation relative to EID-CT, supporting further evaluation in dynamic phantoms and clinical CCTA.

physics.med-ph

A coronary artery phantom for task-based CT performance assessment and a comparative study of clinical CT, photon counting CT, and micro CT

While drastic improvements in CT technology have occurred in the past 25 years, spatial resolution is one area where progress has been limited until recently. New photon counting CT systems, are capable of much better spatial resolution than their (energy integrating) predecessors. These improvements have the potential to improve the evaluation obstructive coronary artery disease by enabling more accurate delineation between calcified plaque and coronary vessel lumen. A new set of vessel phantoms has been designed and manufactured for quantifying this improvement. Comparisons are made between an existing clinical CT system, a prototype photon counting system, with images from a micro CT system being used as the gold standard. Scans were made of the same objects on all three systems. The resulting images were registered and the luminal cross section areas were compared. Luminal cross-sections near calcified plaques were reduced due to blooming, but this effect was much less pronounced in images from the prototype photon counting system as compared to the images from the clinical CT system.

physics.med-ph