SearcharxivSearch

arXiv subjects

Stephen J. Payne

Publications and source records attributed to Stephen J. Payne.

7 recordsLinked to original sources

Stokes flows in a two-dimensional bifurcation

The flow network model is an established approach to approximate pressure-flow relationships in a bifurcating network, and has been widely used in many contexts. Existing models typically assume unidirectional flow and exploit Poiseuille's law, and thus neglect the impact of bifurcation geometry and finite-sized objects on the flow. We determine the impact of bifurcation geometry and objects by computing Stokes flows in a two-dimensional (2D) bifurcation using the LARS (Lightning-AAA Rational Stokes) algorithm, a novel mesh-free algorithm for solving 2D Stokes flow problems utilising an applied complex analysis approach based on rational approximation of the Goursat functions. We compute the flow conductances of bifurcations with different channel widths, bifurcation angles, curved boundary geometries, and fixed circular objects. We quantify the difference between the computed conductances and their Poiseuille's law approximations to demonstrate the importance of incorporating detailed bifurcation geometry into existing flow network models. We parameterise the flow conductances of 2D bifurcation as functions of the dimensionless parameters of bifurcation geometry and a fixed object using a machine learning approach, which is simple to use and provides more accurate approximations than Poiseuille's law. Finally, the details of the 2D Stokes flows in bifurcations are presented.

physics.flu-dyn

A tidal lung simulation to quantify lung heterogeneity with the Inspired Sinewave Test

We have created a lung simulation to quantify lung heterogeneity from the results of the inspired sinewave test (IST). The IST is a lung function test that is non-invasive, non-ionising and does not require patients' cooperation. A tidal lung simulation is developed to assess this test and also a method is proposed to calculate lung heterogeneity from IST results. A sensitivity analysis based on the Morris method and linear regression were applied to verify and to validate the simulation. Additionally, simulated emphysema and pulmonary embolism conditions were created using the simulation to assess the ability of the IST to identify these conditions. Experimental data from five pigs (pre-injured vs injured) were used for validation. This paper contributes to the development of the IST. Firstly, our sensitivity analysis reveals that the IST is highly accurate with an underestimation of about 5% of the simulated values. Sensitivity analysis suggested that both instability in tidal volume and extreme expiratory flow coefficients during the test cause random errors in the IST results. Secondly, the ratios of IST results obtained at two tracer gas oscillation frequencies can identify lung heterogeneity (ELV60/ELV180 and Qp60/Qp180). There was dissimilarity between simulated emphysema and pulmonary embolism (p < 0:0001). In the animal model, the control group had ELV60/ELV180 = 0.58 compared with 0.39 in injured animals (p < 0.0001).

physics.med-ph

Increased blood pressure variability upon standing up improves reproducibility of cerebral autoregulation indices

Dynamic cerebral autoregulation, that is the transient response of cerebral blood flow to changes in arterial blood pressure, is currently assessed using a variety of different time series methods and data collection protocols. In the continuing absence of a gold standard for the study of cerebral autoregulation it is unclear to what extent does the assessment depend on the choice of a computational method and protocol. We use continuous measurements of blood pressure and cerebral blood flow velocity in the middle cerebral artery from the cohorts of 18 normotensive subjects performing sit-to-stand manoeuvre. We estimate cerebral autoregulation using a wide variety of black-box approaches (ARI, Mx, Sx, Dx, FIR and ARX) and compare them in the context of reproducibility and variability. For all autoregulation indices, considered here, the ICC was greater during the standing protocol, however, it was significantly greater (Fisher's Z-test) for Mx (p < 0.03), Sx (p<0.003)$ and Dx (p<0.03). In the specific case of the sit-to-stand manoeuvre, measurements taken immediately after standing up greatly improve the reproducibility of the autoregulation coefficients. This is generally coupled with an increase of the within-group spread of the estimates.

q-bio.QM

Effects of non-physiological blood pressure artefacts on measures of cerebral autoregulation

Cerebral autoregulation refers to regulation mechanisms that aim to maintain cerebral blood flow approximately constant. It is often assessed by autoregulation index (ARI), which uses arterial blood pressure and cerebral blood flow velocity time series to produce a ten-scale index of autoregulation performance (0 denoting the absence of and 9 the strongest autoregulation). Unfortunately, data are rarely free from various artefacts. Here, we consider four of the most common non-physiological blood pressure artefacts (saturation, square wave, reduced pulse pressure and impulse) and study their effects on ARI for a range of different artefact sizes. We show that a sufficiently large saturation and square wave always result in ARI reaching the maximum value of 9. The pulse pressure reduction and impulse artefact lead to a more diverse behaviour. Finally, we characterised the critical size of artefacts, defined as the minimum artefact size that, on average, leads to a 10\% deviation of ARI

q-bio.TO

Bayesian inference in non-Markovian state-space models with applications to fractional order systems

Battery impedance spectroscopy models are given by fractional order (FO) differential equations. In the discrete-time domain, they give rise to state-space models where the latent process is not Markovian. Parameter estimation for these models is therefore challenging, especially for non-commensurate FO models. In this paper, we propose a Bayesian approach to identify the parameters of generic FO systems. The computational challenge is tackled with particle Markov chain Monte Carlo methods, with an implementation specifically designed for the non-Markovian setting. The approach is then applied to estimate the parameters of a battery non-commensurate FO equivalent circuit model. Extensive simulations are provided to study the practical identifiability of model parameters and their sensitivity to the choice of prior distributions, the number of observations, the magnitude of the input signal and the measurement noise.

math.OC

Structural Identifiability Analysis of Fractional Order Models with Applications in Battery Systems

This paper presents a method for structural identifiability analysis of fractional order systems by using the coefficient mapping concept to determine whether the model parameters can uniquely be identified from input-output data. The proposed method is applicable to general non-commensurate fractional order models. Examples are chosen from battery fractional order equivalent circuit models (FO-ECMs). The battery FO-ECM consists of a series of parallel resistors and constant phase elements (CPEs) with fractional derivatives appearing in the CPEs. The FO-ECM is non-commensurate if more than one CPE is considered in the model. Currently, estimation of battery FO-ECMs is performed mainly by fitting in the frequency domain, requiring costly electrochemical impedance spectroscopy equipment. This paper aims to analyse the structural identifiability of battery FO-ECMs directly in the time domain. It is shown that FO-ECMs with finite numbers of CPEs are structurally identifiable. In particular, the FO-ECM with a single CPE is structurally globally identifiable.

math.OC

Mathematical model of the interaction between baroreflex and cerebral autoregulation

Baroreflex (BR) and cerebral autoregulation (CA) are two important mechanisms regulating blood pressure and flow. However, the functional relationship between BR and CA in humans is unknown. Since BR impairment is an adverse prognostic indicator for both cardiac and cerebrovascular diseases it would be of clinical interest to better understand the relationship between BR and CA. Motivated by this observation we develop a simple mathematical framework aiming to simulate the effects of BR on the cerebral blood flow dynamics.

q-bio.TO