Searcharxiv⌕ Search

arXiv subjects

Steve B. Jiang

Publications and source records attributed to Steve B. Jiang.

39 records · Page 3Linked to original sources

GPU-based ultra fast dose calculation using a finite pencil beam model

Online adaptive radiation therapy (ART) is an attractive concept that promises the ability to deliver an optimal treatment in response to the inter-fraction variability in patient anatomy. However, it has yet to be realized due to technical limitations. Fast dose deposit coefficient calculation is a critical component of the online planning process that is required for plan optimization of intensity modulated radiation therapy (IMRT). Computer graphics processing units (GPUs) are well-suited to provide the requisite fast performance for the data-parallel nature of dose calculation. In this work, we develop a dose calculation engine based on a finite-size pencil beam (FSPB) algorithm and a GPU parallel computing framework. The developed framework can accommodate any FSPB model. We test our implementation on a case of a water phantom and a case of a prostate cancer patient with varying beamlet and voxel sizes. All testing scenarios achieved speedup ranging from 200~400 times when using a NVIDIA Tesla C1060 card in comparison with a 2.27GHz Intel Xeon CPU. The computational time for calculating dose deposition coefficients for a 9-field prostate IMRT plan with this new framework is less than 1 second. This indicates that the GPU-based FSPB algorithm is well-suited for online re-planning for adaptive radiotherapy.

physics.med-ph↗

GPU-based ultra fast IMRT plan optimization

The widespread adoption of on-board volumetric imaging in cancer radiotherapy has stimulated research efforts to develop online adaptive radiotherapy techniques to handle the inter-fraction variation of the patient's geometry. Such efforts face major technical challenges to perform treatment planning in real-time. To overcome this challenge, we are developing a supercomputing online re-planning environment (SCORE) at the University of California San Diego (UCSD). As part of the SCORE project, this paper presents our work on the implementation of an intensity modulated radiation therapy (IMRT) optimization algorithm on graphics processing units (GPUs). We adopt a penalty-based quadratic optimization model, which is solved by using a gradient projection method with Armijo's line search rule. Our optimization algorithm has been implemented in CUDA for parallel GPU computing as well as in C for serial CPU computing for comparison purpose. A prostate IMRT case with various beamlet and voxel sizes was used to evaluate our implementation. On an NVIDIA Tesla C1060 GPU card, we have achieved speedup factors of 20-40 without losing accuracy, compared to the results from an Intel Xeon 2.27 GHz CPU. For a specific 9-field prostate IMRT case with 5x5 mm^2 beamlet size and 2.5x2.5x2.5 mm^3 voxel size, our GPU implementation takes only 2.8 seconds to generate an optimal IMRT plan. Our work has therefore solved a major problem in developing online re-planning technologies for adaptive radiotherapy.

physics.med-ph↗

Diaphragm as an anatomic surrogate for lung tumor motion

Lung tumor motion due to respiration poses a challenge in the application of modern three-dimensional conformal radiotherapy. Direct tracking of the lung tumor during radiation therapy is very difficult without implanted fiducial markers. Indirect tracking relies on the correlation of the tumor's motion and the surrogate's motion. The present paper presents an analysis of the correlation between the tumor motion and the diaphragm motion in order to evaluate the potential use of diaphragm as a surrogate for tumor motion. We have analyzed the correlation between diaphragm motion and superior-inferior lung tumor motion in 32 fluoroscopic image sequences from 10 lung cancer patients. A simple linear model and a more complex linear model that accounts for phase delays between the two motions have been used. Results show that the diaphragm is a good surrogate for tumor motion prediction for most patients, resulting in an average correlation factor of 0.94 and 0.98 with each model respectively. The model that accounts for delays leads to an average localization prediction error of 0.8mm and an error at the 95% confidence level of 2.1mm. However, for one patient studied, the correlation is much weaker compared to other patients. This indicates that, before using diaphragm for lung tumor prediction, the correlation should be examined on a patient-by-patient basis.

physics.med-ph↗