SearcharxivSearch

arXiv subjects

Steven A. King

Publications and source records attributed to Steven A. King.

8 recordsLinked to original sources

An Al$^+$ clock with $1.6\times10^{-18}$ systematic uncertainty and its frequency ratios

Advances in optical clocks motivate a redefinition of the second, requiring rigorous evaluations of systematic uncertainties and robust consistency among the clocks. Here, we report the full evaluation of the systematic frequency shifts of an $^{27}\mathrm{Al}^+$ single-ion clock, and the measurement of its absolute frequency and frequency ratio with a $^{87}$Sr optical lattice clock at PTB. The evaluated total systematic fractional frequency uncertainty is $1.6\times10^{-18}$, mainly limited by the accuracy of the relevant atomic coefficients and by background gas collisions. The absolute frequency of the clock has been measured to be $ν_{\mathrm{Al}^+}=1 121 015 393 207 859.19(24)\,$Hz, obtained by comparison with two primary caesium fountain clocks at PTB. The frequency ratio between the Al and Sr optical clocks has been determined to be $ν_{\mathrm{Al}^+}/ν_{^{87}\mathrm{Sr}}=2.611 701 431 781 462 668(36)$, limited by the accuracy of the Sr clock. This ratio differs by $8.6σ$ and $1.2σ$ from the 2021 and 2025 frequency ratio published by the BACON collaboration, respectively. These results represent an important contribution toward a future redefinition of the second using optical clocks, and underscore the importance of independent measurements of clock-candidate frequency ratios across different institutions.

physics.atom-ph

A high-stability optical clock based on a continuously ground-state cooled Al$^+$ ion without compromising its accuracy

Single ion optical clocks have shown systematic frequency uncertainties below $10^{-18}$, but typically require more than one week of averaging to achieve a corresponding statistical uncertainty. This time can be reduced with longer probe times, but comes at the cost of a higher time-dilation shift due to motional heating of the ions in the trap. We show that sympathetic ground-state cooling using electromagnetically-induced transparency (EIT) of an \Al clock ion via a co-trapped \Ca ion during clock interrogation suppresses the heating of the ions. \Al can be kept close to the motional ground state, independent from the chosen interrogation time, at a relative time dilation shift of $(-1.69\pm0.20)\times10^{-18}$. The \Ca cooling light introduces an additional light shift on the \Al clock transition of $(-9.27\pm 1.03)\times10^{-18}$. We project that the uncertainty of this light shift can be further reduced by nearly an order of magnitude. This sympathetic cooling enables seconds of interrogation time with $10^{-19}$ motional and cooling laser-induced uncertainties for \Al and can be employed in other ion clocks as well.

physics.atom-ph

An Optical Atomic Clock Based on a Highly Charged Ion

Optical atomic clocks are the most accurate measurement devices ever constructed and have found many applications in fundamental science and technology. The use of highly charged ions (HCI) as a new class of references for highest accuracy clocks and precision tests of fundamental physics has long been motivated by their extreme atomic properties and reduced sensitivity to perturbations from external electric and magnetic fields compared to singly charged ions or neutral atoms. Here we present the first realisation of this new class of clocks, based on an optical magnetic-dipole transition in Ar$^{13+}$. Its comprehensively evaluated systematic frequency uncertainty of $2.2\times10^{-17}$ is comparable to that of many optical clocks in operation. From clock comparisons we improve by eight and nine orders of magnitude upon the uncertainties for the absolute transition frequency and isotope shift ($^{40}$Ar vs. $^{36}$Ar), respectively. These measurements allow us to probe the largely unexplored quantum electrodynamic nuclear recoil, presented as part of improved calculations of the isotope shift which reduce the uncertainty of previous theory by a factor of three. This work establishes forbidden optical transitions in HCI as references for cutting-edge optical clocks and future high-sensitivity searches for physics beyond the standard model.

physics.atom-ph

Sensitivity to New Physics of Isotope Shift Studies using the Coronal Lines of Highly Charged Calcium Ions

Promising searches for new physics beyond the current Standard Model (SM) of particle physics are feasible through isotope-shift spectroscopy, which is sensitive to a hypothetical fifth force between the neutrons of the nucleus and the electrons of the shell. Such an interaction would be mediated by a new particle which could in principle be associated with dark matter. In so-called King plots, the mass-scaled frequency shifts of two optical transitions are plotted against each other for a series of isotopes. Subtle deviations from the expected linearity could reveal such a fifth force. Here, we study experimentally and theoretically six transitions in highly charged ions of Ca, an element with five stable isotopes of zero nuclear spin. Some of the transitions are suitable for upcoming high-precision coherent laser spectroscopy and optical clocks. Our results provide a sufficient number of clock transitions for -- in combination with those of singly charged Ca$^+$ -- application of the generalized King plot method. This will allow future high-precision measurements to remove higher-order SM-related nonlinearities and open a new door to yet more sensitive searches for unknown forces and particles.

physics.atom-ph

Algorithmic Ground-state Cooling of Weakly-Coupled Oscillators using Quantum Logic

Most ions lack the fast, cycling transitions that are necessary for direct laser cooling. In most cases, they can still be cooled sympathetically through their Coulomb interaction with a second, coolable ion species confined in the same potential. If the charge-to-mass ratios of the two ion types are too mismatched, the cooling of certain motional degrees of freedom becomes difficult. This limits both the achievable fidelity of quantum gates and the spectroscopic accuracy. Here we introduce a novel algorithmic cooling protocol for transferring phonons from poorly- to efficiently-cooled modes. We demonstrate it experimentally by simultaneously bringing two motional modes of a Be$^{+}$-Ar$^{13+}$ mixed Coulomb crystal close to their zero-point energies, despite the weak coupling between the ions. We reach the lowest temperature reported for a highly charged ion, with a residual temperature of only $T\lesssim200~\mathrm{μK}$ in each of the two modes, corresponding to a residual mean motional phonon number of $\langle n \rangle \lesssim 0.4$. Combined with the lowest observed electric field noise in a radiofrequency ion trap, these values enable an optical clock based on a highly charged ion with fractional systematic uncertainty below the $10^{-18}$ level. Our scheme is also applicable to (anti-)protons, molecular ions, macroscopic charged particles, and other highly charged ion species, enabling reliable preparation of their motional quantum ground states in traps.

physics.atom-ph

A cryogenic radio-frequency ion trap for quantum logic spectroscopy of highly charged ions

A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single $^9$Be$^+$ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar$^{13+}$ (Ar XIV) ions concurrently with single Be$^+$ ions, a key prerequisite for the first quantum logic spectroscopy of a highly charged ion.

physics.atom-ph

A self-injection locked DBR laser for laser cooling of beryllium ions

We present a simple, robust, narrow-linewidth, frequency-doubled semiconductor laser source suitable for laser cooling and repumping of $^9$Be$^+$ ions. A distributed Bragg reflector (DBR) laser diode operating at 626 nm is self-injection-locked to a frequency doubling cavity via phase-stabilised optical feedback when the laser is resonant with the cavity mode. The short-term laser instability is reduced from the MHz-level to approximately 20 kHz by the injection process, thus eliminating the need for a high-bandwidth feedback loop to suppress the otherwise troublesome high-frequency laser noise. Long-term stability of the laser frequency is achieved by feeding back to the length of the enhancement cavity utilising an electro-optic frequency comb generator to produce a beatnote with a laser that is detuned by 98 GHz. Long-term injection locking and frequency stabilisation via a wavemeter are ensured using automatic relocking algorithms.

physics.ins-det

Absolute frequency measurement of the $^2$S$_{1/2} \rightarrow ^2$F$_{7/2}$ optical clock transition in $^{171}$Yb$^+$ with an uncertainty of $4\times 10^{-16}$ using a frequency link to International Atomic Time

The highly forbidden $^2$S$_{1/2} \rightarrow ^2$F$_{7/2}$ electric octupole transition in $^{171}$Yb$^+$ is a potential candidate for a redefinition of the SI second. We present a measurement of the absolute frequency of this optical transition, performed using a frequency link to International Atomic Time to provide traceability to the SI second. The $^{171}$Yb$^+$ optical frequency standard was operated for 76% of a 25-day period, with the absolute frequency measured to be 642 121 496 772 645.14(26) Hz. The fractional uncertainty of $4.0 \times 10 ^{-16}$ is comparable to that of the best previously reported measurement, which was made by a direct comparison to local caesium primary frequency standards.

physics.atom-ph